Instruction Manual
Tel:4006602255 86-574-62154079
Fax:86-574-62154679
Website:www.yufengmed.com email:yufeng@yufengmed.com
CONTENTS
3. Specifications .........................................................................................................1
7. Maintenance .......................................................................................................... 6
8. Troubleshooting .................................................................................................... 7
3. Specifications contain any contaminants. If you notice the suction regulator has not been sterilized or
Range Working Gauge contains contaminants, please refer to section 7 for proper sterilizing procedures.
Working Mode Maximum
Model Flow L/min Temperature accuracy 5.2 Connection to vacuum source:
KPa
left right 5.2.1 Connection via Adapter: Suction regulator may connect to the vacuum
terminal directly via a adapter (select the appropriate one while placing the
YF-2XY order).
-25 5.2.2 Before connection, install the adapter into the thread connection on the back of
-25
Off On >35 5-40℃ 4.0 the suction regulator (see Fig 1.), and place the selector switch in “off” position,
YF-2XY turn the adjustment knob counterclockwise to the bottom install the suction
-100
-100 regulator with the adapter into the socket of vacuum terminal till a clicking sound
is heard.
5.2.3 When disassembling, pull out the suction regulator according to the requirements
of different types of terminals.
-1- -2-
5.2.4 Connection via Suction Tubing: In the event of connecting suction kit indirectly 6.3 Pre-use inspection
to the vacuum terminal, soft hose (suction tubing) can be used to connect the 6.3.1 The suction regulator should be used only for the intended use as described in
suction regulator and the vacuum terminal. the section 2. The device should be equipped with suction tip provided by the
5.2.5 According to Fig 1., use the suction tubing(Φ8 or Φ6) to connect the suction medical institutions. Select the appropriate working mode and set the desired
regulator and the supporting accessories. output vacuum pressure based on the actual clinical requirement.
5.3 Inspection after assembly: 6.3.2 Before using, check if the device is in good working condition according to section
5.3.1 Check the assembly of the supporting accessories according to Fig 1. The 5 and Fig 1., and make sure that the suction regulator is correctly attached to the
suction regulator and suction jar should be installed and placed in upright vacuum system.
position, with the angular error less than + 10 degree. Otherwise, the functioning
Note: Place the selector switch in “off” position and turn the adjustment
of suction trap and suction jar shall be affected. knob counterclockwise to the bottom before connecting the suction
5.3.2 Block the outlet of the suction regulator and carry out function tests in the three regulator to the vacuum source. Otherwise, the safety and health of
the patient and operator shall be endangered.
working modes according to Section 7. Check the sealing condition of all joints.
In case of problems, refer to Section 9.
5.4 Disassembly: Disassemble the device in reverse order ofassembly. 6.3.3 Function test
Type Pediatric Adult Place the switch in “off” position, and turn the knob
Model No. “OFF” clockwise to maximum range. When blocking the
YF-2XY-25 YF-2XY-100
Test connection tubing, the gauge has no reading.
-250
6.2 Mode selection: According to clinical requirement, select the appropriate working mode
and place the switch in the corresponding mode position.
-3- -4-
6.4 After inspection, turn the knob counter clockwise to the bottom, and place the switch in Maintenance
off position. 6.6 Sterilization: The device should be sterilized according to relevant medical sterilization
1 Cover
1 Vacuum source 2 Sealing member(seat)
4 Air-compensating orifice
1 7 Suction Kit
1 Sterilant
2 Suction regulator(to be cleaned)
Fig. 2 System Schematic 3 Working suction regulator
4 Vacuum source
5 Suction jar
-5-
-6-
Note: Don’t autoclave the device or sterilize it with disinfectant which No. Problem Probable Cause Remedy
may harm the plastic parts. Increase the vacuum level
Insufficient flow from vacuum source
of the source
7.2. Storage Unable to set Gas leak in the connection tubing Seal the leak
After sterilizing, assemble all the parts back to one piece. Seal all the ports and place high vacuum Defective Gauge
3 Replace O-ring
the suction regulator into a clean and nontoxic plastic bag, then store in a dry, well ventilated pressure in the Inside the O-ring
area. “set” mode Suction
Defective gasket of
Regulator Replace the gasket
7. Troubleshooting the selector switch
Note: Maintenance of the equipment can only be done by trained Unable to adjust Clean the
professionals. Clogged air-compensating orifice or
4 the vacuum air-compensating orifice or
filter
pressure down filter
No. Problem Probable Cause Re
me
Place the switch in 7.
Selector switch not in right place 9.Technical support
appropriate position
9.1 If you encounter a problem that is not mentioned in the troubleshooting section above,
The adjustment knob is turned
Turn the knob please feel free to contact Genstar Technologies. Our technical support staff is here to help
Vacuum gauge counter clockwise to the bottom clockwise
1 you solve your problems in a timely manner. It is important that you provide the following
has no reading Gas leak in suction trap, suction Tighten the cover of
information upon contacting us.
tubing or suction jar suction trap and
9.1.1 Product Model.
suction jar. Check if
9.1.2 Condition of Use
there is gas leak in
9.1.3 Problems
No or low vacuum Ball float valve of suction trap or Discard the
9.1.4 Simplified approach to fix problem.
in the suction suction jar closed excessive liquid 9.2 This device is warranted under normal and proper use, against manufacturing defects
2 tubing
Replace filter from date of purchase for a period of one year. Any failure resulting from defective parts or
(gauge showing Clogged regulator or filter faulty workmanship, as determined during evaluation by the manufacturer, will be repaired
Clear the suction line
vacuum) under warranty.
-7- -8-
10.Symbols
Symbol/Abbreviation Description
Litres per minute
The device complies with the requirements of European
Directive 93/42/EEC relating to medical devices.
Manufacturer
Temperature limit
Keep dry
Humidity limitation
VAC Vaccuum
-9- -10-