WI-MB-04 (Stirrer)

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 8

Holding company for water and waste water

Document ID: WI-MB-04


Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 1 of 8
Working Instruction

Magnetic Stirrer
Heidolph 503-02000-00

Initiated By: ……………………………………………………..


Date: …./…./….
Analytical Chemist

Reviewed By: Technical Review


Date: …./…./….

Approved By: ……………………………………………………

Date: …./…./….
Lab. General manager

WI-IA-009, Issue No. (1) Page 1 of 8


Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 2 of 8
Working Instruction

Contents Page Number

1.0 Scope and Application………………………………………………………. 3

2.0 Definition…………………………………………………………………….. 3

3.0 Precaution…………………………………………………………………… 3

4.0 Procedure…………………………………………………………………… 3

5.0 Maintenance……………………………………………………………….… 3

6.0 Reference…………………………………………………………………….. 3

7.0 Related Forms and Data sheet…………………………………...…………. 4

8.0 Appendices…………………………………………………………………… 4

9.0 Document History……………………………………………………………. 5

WI-IA-009, Issue No. (1) Page 2 of 8


Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 3 of 8
Working Instruction

1. Scope & Applications:


 Mixing solutions rabidly by magnetic rotation mechanism.

2. Definitions:
 None
3. Precautions:
 Do not use this equipment in hazardous areas.

3.1 To avoid electric shock always:
 Use a properly grounded electrical outlet of correct voltage and current handling capacity.
 Disconnect from the power supply prior to maintenance and servicing.
3.2 To avoid personal injury:
 Do not use in the presence of flammable or combustible materials; fire or explosion may result. This
device contains components may ignite such materials.
 Refer servicing to qualified personnel.
 Do not remove or modify grounded power plug. Use only properly grounded outlets to avoid shock
hazard. Not rated for use in hazardous atmospheres.

4. Procedure
4.1 Operation
 The speed control is a combination <on/off> switch and setting selector. The fully counter clockwise
position turns the unit off. To select a speed, turn the speed control clockwise until the desired mixing
action is achieved. The lighted “stir” indicator shows when the unit is stirring.
 Put the materials or solutions in beaker.
 Put a magnet piece inside the beaker.
 Press ON to start the operation.
 Limit the suitable speed by indicator from 1 to 10.
 Ensure that the mixing is finished, at that time press OFF to finish operation.

4.2 Calibration
 Adjust The indicator of rotations on a definite low number and then count by your eyes the rotations
which occurred, if the number difference is found, that mean that device requires to repair.

5. Maintenance
5.1 Preventive Maintenance
5.1.1 Cleaning:
 Only with a damp cloth on the surface, and calibration method.

5.2 Routine Maintenance


 It proceeds by the supplier.

6. References
WI-IA-009, Issue No. (1) Page 3 of 8
Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 4 of 8
Working Instruction

 Instrument Manual

7. Related Forms and Data sheet


 Document History
8. Appendices
 Appendix (1) balance performance Check.
 Appendix (2) balance Maintenance Check.

WI-IA-009, Issue No. (1) Page 4 of 8


Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 5 of 8
Working Instruction

9. Document History
Section Amendment
No. Date Authorization
Para. Page Issue No Elimination / Correction / Addition

WI-IA-009, Issue No. (1) Page 5 of 8


Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 6 of 8
Working Instruction

Appendix (1)
Magnetic stirrer Calibration Check
Instrument Standard
Model Heidolph 503-02000-00 Standard: Stopwatch
S.N: 29110418

WI-IA-009, Issue No. (1) Page 6 of 8


Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 7 of 8
Working Instruction

Appendix (2)
Magnetic stirrer Maintenance Check
Date Initials Action Note
Daily:

Routine Maintenance:

WI-IA-009, Issue No. (1) Page 7 of 8


Holding company for water and waste water
Document ID: WI-MB-04
Sohag Drinking Water & Sanitation Company Issue No. (01)
Laboratories & Quality Sector Issue Date: Oct,2011

Page 8 of 8
Working Instruction

Microbiologist: Microbiology technical manager:

WI-IA-009, Issue No. (1) Page 8 of 8