Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Grease Trap

Ø150 U.G. Ø100 U.G.


IC IC
Slope 1:100
To sewer line
Ø100

Gt
Ø50
Ø100
Re

Store

Counter
Ø100 U.G.
Slope 1:100

Restuarant Space

IC Ø100 Gt
Ø100 Trapless Entrance
floor drain

Ø40

GROUND FLOOR PLAN-


NYAMA CHOMA ZONE
TITLE GROUND FLOOR PLAN- NYAMA CHOMA ZONE CLIENT. ELIZABETH KAMENE NDOLO, PREPARED BY: W.N.F DRWG SIZE:
DRAINAGE LAYOUT P.O. BOX 54, SULTAN HAMUD
PROJECT PROPOSED COMMERCIAL DEVELOPMENT ON
LR. 1757/28, SUB PLOT A1& B1. MAKUENI COUNTY DRAWING REF. CHU - 101 VERIFIED BY: ............. SCALE: N.T.S

ARCHITECT PLANOCONSULT ARCHITECTS AND PLANNERS P.O BOX 47761 - 00100 NAIROBI REVISION:- REASON:- DATE: FEB 2023 APPROVED BY: ............. DATE: FEB 2023
NYAMA CHOMA ZONE

MWS From Elevated Tank

Ø25

Ø25

Ø25 F/B

Ø32
Store Counter
fall

Restuarant Space Tempering valve

fall 1no. solar panelfall


tank cap: 300 Ltrs

Solar panel
Entrance
Ø32 F/B Solar Feed
Ø25 HWS F/A CO2 DP
Ø32 Ø25
Ø25

ROOF PLAN
GROUND FLOOR PLAN-
NYAMA CHOMA ZONE

TITLE GROUND FLOOR PLAN- NYAMA CHOMA ZONE CLIENT. ELIZABETH KAMENE NDOLO, PREPARED BY: W.N.F DRWG SIZE:
PLUMBING LAYOUT P.O. BOX 54, SULTAN HAMUD
PROJECT PROPOSED COMMERCIAL DEVELOPMENT ON
LR. 1757/28, SUB PLOT A1& B1. MAKUENI COUNTY DRAWING REF. CHU - 102 VERIFIED BY: ............. SCALE: N.T.S

ARCHITECT PLANOCONSULT ARCHITECTS AND PLANNERS P.O BOX 47761 - 00100 NAIROBI REVISION:- REASON:- DATE: FEB 2023 APPROVED BY: ............. DATE: FEB 2023
Gutter 150Ø Half-Round 150Ø Half-Round Gutter
Outlets UPVC Pipe UPVC Pipe Outlets
To storm Drain To storm Drain
Landing Shoe Landing Shoe
110Ø RWDP F/A 110Ø RWDP F/A

Store
fall
Counter

Restuarant Space
fall fall
Entrance
fall
110Ø RWDP F/A 110Ø RWDP F/A
Landing Shoe Landing Shoe

To storm Drain To storm Drain


Gutter 150Ø Half-Round 150Ø Half-Round Gutter
Outlets UPVC Pipe UPVC Pipe Outlets
GROUND FLOOR PLAN-
NYAMA CHOMA ZONE ROOF PLAN

TITLE GROUND FLOOR PLAN- NYAMA CHOMA ZONE CLIENT. ELIZABETH KAMENE NDOLO, PREPARED BY: W.N.F DRWG SIZE:
RAINWATER DRAINAGE LAYOUT P.O. BOX 54, SULTAN HAMUD
PROJECT PROPOSED COMMERCIAL DEVELOPMENT ON
LR. 1757/28, SUB PLOT A1& B1. MAKUENI COUNTY DRAWING REF. CHU - 103 VERIFIED BY: ............. SCALE: N.T.S

ARCHITECT PLANOCONSULT ARCHITECTS AND PLANNERS P.O BOX 47761 - 00100 NAIROBI REVISION:- REASON:- DATE: FEB 2023 APPROVED BY: ............. DATE: FEB 2023

You might also like