ACI 318M-02 Wall

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Wall Design ACI318M-02

Bearing

Designed by ACI Section 14.5


Tham & Wong VN Date 16.09.2007
Designed By Ronald Kury
Project: Example 01
Shear Wall Design (ACI318M-02)
Marking: W1 from Basement to Ground Floor

1. Input Data
Ultimate Axial Load Pu = 2539 kN
Ultimate Moment Mu = 0 kN-m
Ultimate Base Shear Force Vu = 0 kN
Minmum Moment Mmin = kN-m
fy = 390 N/mm2
fc' = 37 N/mm2
ø= 0.75
Unsupported wall height lu = 4200 mm
Wall thickness t= 200 mm
Wall length lw = 2800 mm
effective depth d= 2240 mm
Ag = 560000 mm2
Slenderness ratio = 14
Minimum Thickness of Wall tmin = 210 mm

2. Does the shear reinforcement require?


Shear capacity of concrete øVc = 341 kN < Vu Shear reinforcement is not required, provide the
minimum

3. Minimum steel required


Minimun horizontal rebar Asmin = 1120 mm
Minimum vertical steel Asmin = 672 mm

4. Spacing Limit
Max horizontal rebar spacing = 450 mm
Max vertical rebar spacing = 450 mm

5. Select the horizontal rebar.


Select horizontal rebar diameter = 10 mm
Select horizontal rebar spacing s= 200 mm
Provided horizontal rebar area As = 1758 mm2 OK

Required horizontal rebar capacity Vsreq = NA kN


Provided shear link (horizontal rebar) capacity Vsprov = 65 kN OK

Design Assumption
1. Vertical and horizontal rebars were provided at each face of the wall. (i.e provided in two layers.)

References
1. American Concrete Institute Committee 318. 2002. "Building Code Requirements for Structural Concrete (ACI 318M-02) and Commetary (ACI318RM-02)". USA.
2. J.G.MacGregor. J.K.Wight. 2005. "Reinforced Concrete: Mechanics and Design". 4th Edition. SI Edition by S.Teng, I. Paulus. Pearson. Singapore.