Professional Documents
Culture Documents
ACI 318M-02 Wall
ACI 318M-02 Wall
ACI 318M-02 Wall
Bearing
1. Input Data
Ultimate Axial Load Pu = 2539 kN
Ultimate Moment Mu = 0 kN-m
Ultimate Base Shear Force Vu = 0 kN
Minmum Moment Mmin = kN-m
fy = 390 N/mm2
fc' = 37 N/mm2
ø= 0.75
Unsupported wall height lu = 4200 mm
Wall thickness t= 200 mm
Wall length lw = 2800 mm
effective depth d= 2240 mm
Ag = 560000 mm2
Slenderness ratio = 14
Minimum Thickness of Wall tmin = 210 mm
4. Spacing Limit
Max horizontal rebar spacing = 450 mm
Max vertical rebar spacing = 450 mm
Design Assumption
1. Vertical and horizontal rebars were provided at each face of the wall. (i.e provided in two layers.)
References
1. American Concrete Institute Committee 318. 2002. "Building Code Requirements for Structural Concrete (ACI 318M-02) and Commetary (ACI318RM-02)". USA.
2. J.G.MacGregor. J.K.Wight. 2005. "Reinforced Concrete: Mechanics and Design". 4th Edition. SI Edition by S.Teng, I. Paulus. Pearson. Singapore.