ChemFlo As

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

CHEM COATS PRIVATE LIMITED 

ChemFlo AS
 Antistatic self‐levelling epoxy floor system
DESCRIPTION APPLICATION

ChemFlo AS is a pigmented, ready-to-use, solvent-free The A-component must be stirred for at least 1–2
2-component floor coating system of high-grade epoxy minutes. Then the entire content of the B-component is
resin. ChemFlo AS used with the conductive layers emptied into the A-component container and the two
ChemFlo AS Primer, produces tough, electrically components are homogeneously mixed using a suitable
conductive coatings according to DIN 51953 / electric stirrer (for at least 2–3 minutes). The inclusion of
DIN EN 1081 / DIN IEC 93, which are easy to clean and air in the mixing process is to be avoided. The mixture is
exhibit a good level of resistance to fuels and lubricants, poured into another container and briefly stirred again.
most solvents and many chemicals. ChemFlo AS is poured onto the surface and spread over
the entire area using a serrated spatula (tooth size no.
USES 25) (layer thickness control). The fluid coating can be
rolled with a spiked roller, as required. The operative
ChemFlo AS is used as a conductive surface coating wears spiked shoes to walk on the still wet coating. It may
system for industrial floors with high demands in terms of be necessary to activate the floor coating electrically after
electrostatic discharge, especially in explosion proof it has fully cured.
areas and fire protection zones.
Areas of application are chemical plants, places where
organic (flammable) solvents are stored and surrounding PHYSICAL PROPERTIES
areas, hospitals, operating theatres electronic
manufacturing, packing and others. LIQUID MIXTURE (A+B)
98%
ANTISTATIC FLOORING SYSTEM Solid Content
Solvent/ Additives 2%
ChemFlo AS is used as a topcoat for the following Density (20º C) 1.5 g/cm
3

antistatic flooring system: Viscosity (20º C) 2800-3800 mPas


 ChemFlo AS Conductive
Packaging size 25 Kgs
Colour A range of colours available
FINISHED SURFACE CHARACTERISTICS
Shelf life / storage 1 year at 15–20°C
 Total coating thickness of system 2-3mm is
achieved and preferred.
 Topcoat thickness, 1.3-1.5mm.
Due to addition of aggregate and fiber in material, the PROPERTIES OF DRY FILM
finished surface will have slight textured finish.
Bending tensile strength 45 N/mm2
MAINTENANCE & CARE (DIN EN 196 / ASTM C 190)

Compressive strength 73 N/mm2


In order to retain the quality of the synthetic resin flooring
(DIN EN 196 / ASTM C 109)
for a long time we recommend regular cleaning, care, and
maintenance programme. Adhesive pull strength > 2.5 N/mm2
(DIN ISO 4624) (concrete failure)
SURFACE PREPARATION Abrasion resistance
79 mg/1000 cycles
(DIN 53754 / ASTM D 1044)
The substrate must be clean and free of dust and loose
particles. All traces of contaminants such as oils, fats, Shore-D-hardness
greases, paint residues, chemicals, algae and laitance (DIN 53505 / ASTM D 2240) 82
should be removed.
ChemFLo AS is poured onto the conductive layers Earth leakage resistance
ChemFlo AS Primer. The conductive coating layer must (ASTM F150-78) 5x104 to 1x106 ohms
be applied no later than 24 hours after the previous layer
has been laid. Light-fastness 7
(DIN EN ISO 105-B02) (Scale 1–8, 8=best)


CHEM COATS PRIVATE LIMITED
Monnoo Chowk, Defence Road, Off Raiwind Road, Near Nobel TV, Lahore, Pakistan.
Tel: +92 42 35322201-03 Fax: +92 42 35322204 www.chemcoats.com.pk Email: info@chemcoats.com.pk
 
CHEM COATS PRIVATE LIMITED 
 
PHYSICAL PROPERTIES
IMPORTANT NOTE
LIQUID MIXTURE (A+B)
100 : 19 by weight
The information given in this data sheet is based on
Mixing ratio A : B current development work and many years of field
Processing time (20°C) 20–25 min. experience. Whilst every effort is made to ensure that the
Processing temperature 15–25°C (min. 3°C above information is reliable, we cannot accept responsibility for
Material consumption approx. 1800 g/m2 any work carried out with our materials as we have no
Can be walked on (20°C) after approx. 24 hours
controls over methods of applications, site conditions etc.
In view of the continuing research and development being
Consecutive layer (20°C) within 12–24 hours
undertaken in our laboratories we advice customers in
their own interest to ensure that this data sheet has not
Fully capable of withstanding
been superseded by a more up-to-date publication. All
stress
mechanical (20°C) products are sold subject to our standard conditions of
after 7 days
chemical (20°C) sale which are available on request. Field services, where
after 28 days
provided, does not constitute supervisory responsibility.
For additional information, please contact your local
REWORKING ChemCoats representative.
If reworking the coating layer within 24 hours after
application the layer need not be ground. Reworking after
that is only possible after grinding it carefully.

PROTECTION/MAINTENANCE ON COMPLETION

Protect surface against traffic and spillage until cured.

PACKAGING

ChemFlo AS is supplied in 25 kg pack.

HANDLING & STORAGE

ChemFlo AS has a shelf life of 12 months if kept in a dry,


cool store in the original, unopened packs. If stored at
high temperatures and/or high humidity conditions, the
shelf life may be reduced.

HEALTH & SAFETY

Appropriate health and safety advice can be found in the


Material Safety Data Sheets. Users are advised to wear
gloves and eye protection when mixing or applying
ChemFlo AS.
When cured, ChemFlo AS is inert and harmless.

RANGE OF PRODUCTS
WATERPROOFING SYSTEMS PREPACKED REPAIR MORTARS SEALANTS
INDUSTRIAL FLOOR SURFACES CEMENTITIOUS & EPOXY GROUTS CRACK INJECTION
PROTECTIVE COATINGS CONCRETE ADMIXTURES CONCRETE ADHESIVE


CHEM COATS PRIVATE LIMITED
Monnoo Chowk, Defence Road, Off Raiwind Road, Near Nobel TV, Lahore, Pakistan.
Tel: +92 42 35322201-03 Fax: +92 42 35322204 www.chemcoats.com.pk Email: info@chemcoats.com.pk
 