Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Culligan International(Emirates) Culligan International(Emirates)

P.O.Box:37728, Dubai, P.O.Box:129054, Abu Dhabi,


WATER TREATMENT SERVICE United Arab Emirates United Arab Emirates
REPORT Tel:+971-4-3389 8880 Tel:+971-4-3389 8880
Tel:+971-4-3389 8881 Tel:+971-4-3389 8881

E-Report No.: 40349


Cull Ref: 4307
Date 08-10-2019
Client: Zumurud Tower Owners Association
Contact: Mr. Santhosh
Site/Project: Zumurud Tower - Dubai Marina
System: Swimming
Circuits Ref: SC-SP
Page No: 1 of 2

Total Calcium Free


Sample Total Iron Cyanuric Saturation Suspended Tem
pH Conductivity TDS Alkalinity Hardness Chlorine pera
Point ppm Acid ppm Index ppm solids
ppm ppm ppm ture
Control 7.4-7.6 70-100 100-500 1.0-2.0 20-60
limit
Main pool 7.58 3071 2397 70 >500 0.22 >60
Jacuzzi 7.63 4599 3714 100 >500 1.67 >60

Stage Witnessed & Analysed by Culligan Culligan Scope


Before/Afte
Post Post
Plain Cleaning r Flushing
Cleaning Passivation Passivation Supervision Chemicals Analysis Other
Flushing Chemical Final Pumps
Chemical Chemical Chemical

Chemical Dosing system


Water Consumption Previous New Dosage/Pump Old Controller New Controller
Treatment
as m3 / Days Dosage/Pump Settings Settings Settings Settings

Comments:

In Main pool,

(a)Water analysis indicates that Free Chlorine level is low and Cyanuric acid level is high.

(b)Calcium hardness level is also high.

In Jacuzzi,

(a)Water analysis indicates that Free Chlorine level is maintained satisfactory but Cyanuric acid level is
high.

(b)Calcium hardness level is also high.

Recommendations:

(a)Kindly drain the water from both the pool and Jacuzzi to bring down the calcium hardness level,

(b)Maintain free chlorine level between 1.0-2.0 ppm.

(c)Maintain and check free chlorine and pH level daily basis.

(d)Maintain cyanuric acid level between 20-60ppm.

(e)Maintain PH level between 7.4-7.6,

Certified that the water treatment programme at the client address has been tested in accordance with the specifi cation agreed between the client and Culligan,and conforms in all relevant respects, except where stated. The
recommended action is agreed by the client.
TOTAL SOLUTIONS FOR: COOLINGlHEATINGlMEMBRANE SYSTEMS l POTABLE WATER l POOLS & SPAS l WASTEWATER
Culligan International(Emirates) Culligan International(Emirates)
P.O.Box:37728, Dubai, P.O.Box:129054, Abu Dhabi,
WATER TREATMENT SERVICE United Arab Emirates United Arab Emirates
REPORT Tel:+971-4-3389 8880 Tel:+971-4-3389 8880
Tel:+971-4-3389 8881 Tel:+971-4-3389 8881

E-Report No.: 40349


Cull Ref: 4307
Date 08-10-2019
Client: Zumurud Tower Owners Association
Contact: Mr. Santhosh
Site/Project: Zumurud Tower - Dubai Marina
System: Swimming
Circuits Ref: SC-SP
Page No: 2 of 2

(f)Clean the pools frequently.

Engineer’s Name :
Mohamed Fazil
Mobile No
0566579654
Emp. No.

Client Name.: Mr. Santhosh


Mobile No 0524817211
Emp. No.

Certified that the water treatment programme at the client address has been tested in accordance with the specifi cation agreed between the client and Culligan,and conforms in all relevant respects, except where stated. The
recommended action is agreed by the client.
TOTAL SOLUTIONS FOR: COOLINGlHEATINGlMEMBRANE SYSTEMS l POTABLE WATER l POOLS & SPAS l WASTEWATER

You might also like