OPERATING AND MAINTENANCE

MC 86 E
SECTION 1

OPERATING PRINCIPLES

Injecting Oil

Separating the Oil from the Air

The Minimum Pressure and No Return Valve


SECTION 1

OPERATING PRINCIPLES

Cooling the Oil

The Intake Valve


SECTION 2

ADJUSTMENT

Version 150 PSI


Servo valve 150 PSI
P max 147 PSI
P min 127 PSI
SECTION 3

MAINTENANCE
Checking the oil level

Cleaning and/or Replacing the Air Intake Filter

Cleaning the Oil Radiator

Cleaning and/or Replacing the Oil Return Valves


SECTION 3

MAINTENANCE
Replacing the Oil Filter

Replacing the Air-Oil Separator Element


SECTION 3

MAINTENANCE

First and Subsequent Oil Changes

MC 86 E OIL CAPACITY = 1 GALLON

Disposal
SECTION 5

SERVICE KITS/PARTS

• OIL CHANGE KIT 45328


• MATTEI OIL (1-gallon) 26017
• MATTEI OIL (5-gallon) 26019
• INTAKE FILTER 45323
• OIL RETURN VALVES 45330
• NON RETURN VALVE 45331
• OIL FILTER 45334
• THERMOSTATIC BYPASS VALVE 45338
• MATTEI SEPARATOR CHANGE KIT 45339
• OFFLOAD VALVE 45329
• PRESSURE RELIEF VALVE 45341
• SERVO VALVE 45342
• INTAKE VALVE 45343
• VACUUM RELIEF VALVE 45344
SECTION 5

MAINTENANCE SCHEDULE

400 HOURS (BREAK-IN) PART NUMBER


• Change Oil – 1 gallon Mattei Oil 26017
• Clean Oil Filter – 1 oil change kit 45328
• Clean Oil Return Valves

2000 HOURS PART NUMBER


• Change Air Filter 45323
• Change Oil Return Valves 45320
• Change Oil Filter 45334
• Change Oil – 1 gallon Mattei Oil 26017
• Blow out Radiator

4000 HOURS PART NUMBER


• Change Air Filter 45323
• Change Oil Return Valves 45320
• Change Oil Filter 45334
• Change Separator 45339
• Change Oil – 1 gallon Mattei Oil 26017
• Blow out Radiator