Calibration Report No.

S 6575 / LCA / 420

Jack Capacity : 3000kN Jack Serial No. : BBRM-300-ME-03 Jack Ram Area : 550.0cm 2 (85.25 in 2 )
Jack Type : MULTI-JACK Jack Stroke : 245mm Date of Calibration : 30.10.2018
0.6"(15.70mm) Strand Strand UTS = 279kN
Strands 70%UTS 71%UTS 72%UTS 73%UTS 74%UTS 75%UTS 76%UTS 77%UTS 78%UTS 79%UTS 80%UTS
per Jacking Jacking Jacking Jacking Jacking Jacking Jacking Jacking Jacking Jacking Jacking
tendon pressure pressure pressure pressure pressure pressure pressure pressure pressure pressure pressure
(psi) (psi) (psi) (psi) (psi) (psi) (psi) (psi) (psi) (psi) (psi)
706 3625 3675 3726 3777 3828 3879 3930 3980 4031 4082 4133
806 4133 4191 4249 4307 4365 4423 4481 4539 4598 4656 4714
906 4641 4706 4772 4837 4903 4968 5033 5099 5164 5229 5295
1006 5149 5222 5295 5367 5440 5512 5585 5658 5730 5803 5875
1106 5658 5737 5817 5897 5977 6057 6137 6217 6297 6376 6456
1206 6166 6253 6340 6427 6514 6601 6689 6776 6863 6950 7037
1306 6674 6768 6863 6957 7052 7146 7240 7335 7429 7524 7618
1406 7182 7284 7386 7487 7589 7691 7792 7894 7995 8097 8199
1506 7691 7799 7908 8017 8126 8235 8344 8453 8562 8671 8780
Equation of linear regression y = 2.6127x + 41.2598
Pressure in psi , y = mx + c Example ( for 1006 tendon stressed @ 75% UTS)
where , m = gradient Jacking pressure in psi = 2.6127 x (10 x 279 x 0.75) + 41.2598
x = true force in kN = 5512 psi
c = constant value in psi approx = 5500 psi