Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7

:
:
F F
: :
INDOOR LIGHTING FIXTURE POWER SYSTEM DATA/VOICE SYSTEM CCTV SYSTEM QUEUING SYSTEM
Since 1957
B.N SYMBOLS DESCRIPTIONS
SYMBOLS DESCRIPTIONS B.N SYMBOLS DESCRIPTIONS B.N SYMBOLS DESCRIPTIONS B.N SYMBOLS DESCRIPTIONS
DISTRIBUTION BOARD MAIN CUSTOMER QUEUE LED DISPLAYING PANEL WITH ALL ACCESSORIES.
MQD
DB MDVR MDVR NVR NVR
SPOT LIGHTING FIXTURE MAIN DATA AND VOICE RACK NETWORK VIDEO RECORDER RACK
SUB MAIN DISTRIBUTION BOARD
SDVR SDVR ID
TD TELLER DISPLAY WITH ALL ACCESSORIES.
:
600x600 MODULAR LIGHTING FIXTURE SMDB SUB MAIN DATA AND VOICE RACK INDOOR DOME CAMERA
WALL MOUNTED SINGLE SOCKET, 16 A , 220 A , TYPE F (L+N+E) WP,h TELEPHONE SOCKET RJ45 (WALL MOUNTED) T,L,F FIXED CAMERA
h,W.P TM TICKET DISPLAYING MACHINE WITH ALL ACCESSORIES.
RECTANGULAR LIGHTING FIXTURE - CELING SS T IB W.P
(E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') ( WP='WEATHER PROOF' , h ='HEIGHT') W.P=WEATHER PROOF ,T: THERAMAL CAMERA, L: LPR CAMERA, F: FISH EYE CAMERA)
h,W.P WALL MOUNTED DUPLEX SOCKET, 16 A , 220 A , TYPE F (L+N+E) X,WP,h DATA SOCKET RJ45 (WALL MOUNTED) T,L,F OUTDOOR BULLET CAMERA QUEUING CONTROL UNIT AND SOUND SYSTEM RACK WITH ALL ACCESSORISE
Q&S QUE. PANEL
RECTANGULAR LIGHTING FIXTURE - WALL TS D OB
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') ( AP='ACCESS POINT' , C='CAMERA' , D='DUPLEX' , AC='ACCESS CONTROL' , TT='TURNSTILE' ,WP='WEATHER PROOF' , h ='HEIGHT') W.P W.P=WEATHER PROOF ,T: THERAMAL CAMERA, L: LPR CAMERA, F: FISH EYE CAMERA)
h,W.P WALL MOUNTED POWER SOCKET, 16 A , 220 A , TYPE F (L+N+E) DUBLEX DATA SOCKET RJ45 (WALL MOUNTED) SOUND OUTLET
h SO
LO PO DD
RECTANGULAR LIGHTING OUTLET - WALL (h ='HEIGHT')
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT')
LANDSCAPE LIGHTING FIXTURE
XA,h,W.P WALL MOUNTED SINGLE PHASE INDUSTRIAL SOCKET, 220V (L+N+E) ,CURRENT RATING AS INDCATED ON PLAN WP,h IP TV SOCKET RJ45 (WALL MOUNTED) CALLING PAD
CP
EXHAUST FAN OUTLET 1/IS TV
(X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') ( WP='WEATHER PROOF' , h ='HEIGHT')
E WALL MOUNTED SINGLE PHASE INDUSTRIAL SOCKET, 2200V (L+N+E) ,CURRENT RATING AS INDCATED ON PLAN TELEPHONE SOCKET RJ45 (CEILING MOUNTED) SYMBOLS DESCRIPTIONS E
XA,h,W.P WP,h
EXIT SIGN - CELING 1/IS T
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') ( WP='WEATHER PROOF' , h ='HEIGHT')
WALL MOUNTED THREE PHASE INDUSTRIAL SOCKET, 380V (3L+N+E) ,CURRENT RATING AS INDCATED ON PLAN DATA SOCKET RJ45 (CEILING MOUNTED) FLOOD LIGHT ON POSTS , 4000W PER POST ,REFER TO LANDSCPAE
X,WP,h
XA,h,W.P
EXIT SIGN - WALL 3/IS D
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') (AP='ACCESS POINT' , C='CAMERA' , D='DUPLEX' , AC='ACCESS CONTROL' , TC='THERMAL CAMERA' ,
WP='WEATHER PROOF', h ='HEIGHT')
ACCESS CONTROL SYSTEM
CELING MOUNTED SINGLE SOCKET, 16 A , 220 A , TYPE F RECESSED FLOOR LIGHT , 12W ,REFER TO LANDSCPAE
P1
IP TV SOCKET RJ45 (CEILING MOUNTED)
h,W.P WP,h
SS TV
OUTDOOR LIGHTING POLE , SINGLE ARM
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') (AP='ACCESS POINT' , C='CAMERA' , D='DIGITAL SIGN' , AC='ACCESS CONTROL' , WP='WEATHER PROOF', h ='HEIGHT') B.N SYMBOLS DESCRIPTIONS
CEILING MOUNTED DUPLEX SOCKET, 16 A , 220 A , TYPE F FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (2NO. NORMAL DUPLEX SOCKET RECESSED STAIR LIGHT , 1W ,REFER TO LANDSCPAE
h,W.P FB-01
BELL OUTLET FOR SUMMONING SYSTEM TS F.B CRD CARD READER WITH BIOMETRIC (FINGERPRINT) FOR ACCESS CONTROL SYSTEM
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') , 1NO HDMI OUTLET , 2NO.DATA SOCKET RJ45)
:
CEILING MOUNTED POWER SOCKET, 16 A , 220 A , TYPE F FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (2NO. NORMAL DUPLEX SOCKET RECESSED WALL MOUNTED LIGHT AT , 8W ,REFER TO LANDSCPAE
h,W.P FB-02
PUSH BUTTON FOR SUMMONING SYSTEM PO F.B DL DOOR LOCK FOR ACCESS CONTROL SYSTEM.
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') , 2NO.DATA SOCKET RJ45)
CEILING MOUNTED SINGLE PHASE INDUSTRIAL SOCKET, 220V (L+N+E) ,CURRENT RATING AS INDCATED ON PLAN FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (1NO. EMERGENCY DUPLEX SOCKET,2NO.DATA SOCKET RJ45 ) SPOT DOWN LIGHT ,8W ,REFER TO LANDSCPAE
XA,h,W.P FB-03
B LETTER (B) INDICATES THAT THE FIXTURE IS EQUIPED WITH BUILT-IN BATTERY 1/IS F.B PB REQUEST TO EXIT PUSH BUTTON.
(X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT') ,1NO.HDMI OUTLET)
CEILING MOUNTED THREE PHASE INDUSTRIAL SOCKET, 380V (3L+N+E) ,CURRENT RATING AS INDCATED ON PLAN FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (1NO. UPS DUPLEX SOCKET,2NO.DATA SOCKET RJ45 ) FLOOD LIGHT ON PARAPET , 75W ,REFER TO LANDSCPAE
XA,h,W.P FB-04
E LETTER (E) INDICATES THAT THE FIXTURE FEED FROM EMERGENCY SOURCE 3/IS F.B DC DOOR CONTROLLER.
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT')
FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (2NO. NORMAL DUPLEX SOCKET TABLE BOX , IP67 , WEATHER PROOF CONTAINS (1NO. EMERGENCY DUPLEX SOCKET, WALL APPLIQUE FOR FENCE , 8W ,REFER TO LANDSCPAE
FB-01 TB-01
LO LETTER (LO) INDICATES LIGHTING OUTLET F.B T.B
, 1NO HDMI OUTLET , 1NO.DATA SOCKET RJ45 )
, 1NO HDMI OUTLET , 2NO.DATA SOCKET RJ45)
FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (2NO. NORMAL DUPLEX SOCKET FLOOR SPOT FOR FENCE , 12W ,REFER TO LANDSCPAE
FB-02
W.P LETTER (W.P) INDICATES WEATHER PROOF F.B HDMI KNX SYSTEM
, 2NO.DATA SOCKET RJ45) HDMI OUTLET FOR PROJECTOR (WALL MOUNTED)
FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (1NO. EMERGENCY DUPLEX SOCKET,2NO.DATA SOCKET RJ45 ) ELECTRICITY OUTLET , 40W ,REFER TO LANDSCPAE
FB-03 B.N SYMBOLS DESCRIPTIONS
F.B HDMI
,1NO.HDMI OUTLET) HDMI OUTLET FOR PROJECTOR (CEILING MOUNTED)
FB-04 FLOOR BOX , IP67 , WEATHER PROOF CONTAINS (1NO. UPS DUPLEX SOCKET,2NO.DATA SOCKET RJ45 ) DATA OUTLET WITH EMPTY CONDUIT (WALL MOUNTED) KB1 KNX TOUCH SCREEN KEYPAD 7 INCH
X,h
F.B DO
LIGHTING SWITCHES (AP='ACCESS POINT' , C='CAMERA' , D='DUPLEX' , AC='ACCESS CONTROL', h ='HEIGHT') FIRE ALARM SYSTEM
D TB-01 TABLE BOX , IP67 , WEATHER PROOF CONTAINS (1NO. EMERGENCY DUPLEX SOCKET,
h
DUBLEX DATA OUTLET WITH EMPTY CONDUIT (WALL MOUNTED) KB2 KNX TOUCH SCREEN KEYPAD 10 INCH D
T.B DO
SYMBOLS DESCRIPTIONS
, 1NO HDMI OUTLET , 1NO.DATA SOCKET RJ45, 1NO.PUSH BUTTON ) ( h ='HEIGHT') B.N SYMBOLS DESCRIPTIONS
PUSH BUTTON , TO SHUTDOWN ELECTRICAL POWER FOR STUDENT SOCKETS
X
DATA OUTLET WITH EMPTY CONDUIT (CEILING MOUNTED) KNX-CP KNX CONTROL PANEL (XX-FLOOR & YY-PART NO.) :
PB DO r
( AP='ACCESS POINT' , C='CAMERA' , D='DUPLEX' , AC='ACCESS CONTROL ' ) H H ADDRESS HEAT DETECTOR (r: RATE OF RISE)
LIGHTING SWITCH ONE WAY ONE GANG
FLOOR MOUNTED ELECTRICAL OUTLET 1-THE DEFAULT HEIGHT FOR ALL ELECTRICAL FIXTURES EQUAL 400mm FROM F.F.L IF IS NOT MENTIONED WITH ('h1','h2','h3','h4').
EO 2- THE HEIGHT (h1=1200mm, h2=1300mm, h3=1800mm, h4=2200mm) FROM F.F.L X
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF') S ADDRESSABLE SMOKE DETECTOR (afc: ABOVE FALSE CELING, sb: SOUNDER BASED)
3- ALL ELECTRICAL FIXTURES ARE FEED FROM NORMAL CIRCUITS IF IS NOT MENTIONED WITH ('E' OR 'U'). S
LIGHTING SWITCH ONE WAY TWO GANGS
HD,h WALL MOUNTED ELECTRICAL OUTLET
EO S
( HD='HAND DRYER', h=' HEIGHT') SW ADDRESSABLE SMOKE DETECTOR (WALL MOUNTED)
LIGHTING SWITCH ONE WAYTHREE GANGS
CEILING MOUNTED ELECTRICAL OUTLET
h 1− ALL ELECTRICAL INSTALLATION SHALL BE IN CONFORMITY WITH THE REGULATION OF LOCAL
EO x AUTHORITIES AND LATEST I.E.E. REGULATIONS. THIS TENDER DOCUMENT SHALL BE CONSIDERED AS OUR
( E='EMERGRNCY', U='UPS', WP='WEATHER PROOF') M ADDRESSABLE MULTI DETECOR (afc: ABOVE FALSE CELING)
LIGHTING SWITCH TWO WAY ONE GANG PUBLIC ADDRESS SYSTEM M
MINIMUM REQUIREMENT.
XA,nP,N,h,WP,F WALL MOUNTED SINGLE PHASE DISCONNECT SWITCH, 220V ,CURRENT RATING AS INDCATED ON PLAN 2− THE CONTRACTOR SHALL CO−ORDINATE WITH THE LOCAL SUPPLY AUTHORITY AND SHALL BE
RESPONSIBLE FOR MAKING ALL NECESSARY ARRANGEMENT FOR OBTAINING ELECTRIC SUPPLY FOR THE
1/DS
(n='NUMBER OF POLES', X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT', F='FUSED'). LH LH LINEAR HEAT DETECTOR PANEL PREMISES.
LIGHTING SWITCH TWO WAY TWO GANGS B.N SYMBOLS DESCRIPTIONS
3− THE LAYOUT DRAWINGS DO NOT SHOW ALL THE SYSTEMS, ITEMS, OR ACCESSORIES COVERED UNDER THE
XA,nP,N,h,WP,F,S WALL MOUNTED THREE PHASE DISCONNECT SWITCH, 380V ,CURRENT RATING AS INDCATED ON PLAN SCOPE OF ELECTRICAL WORKS TO BE EXECUTED THE LAYOUT DRAWINGS SHALL BE READ IN CONJUNCTION
3/DS WITH ALL RELEVANT OR SPECIALIST DRAWINGS AND SPECIFICATIONS.
LIGHTING SWITCH TWO WAY THREE GANGS (n='NUMBER OF POLES', X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT', F='FUSED',) LHS LINEAR HEAT SENSING CABLE
SSR SSR SOUND SYSTEM RACK
4− DO NOT SCALE FROM THE LAYOUT DRAWINGS WORK ACCORDING TO ARCHITECTURAL, ID DRAWINGS OR
XA,nP,N,h,WP,F,S
ELECTRICAL DETAILS UNLESS OTHERWISE AUTHORIZED.
CEILING MOUNTED SINGLE PHASE DISCONNECT SWITCH, 220V ,CURRENT RATING AS INDCATED ON PLAN
1/DS 5− ALL EQUIPMENT LAYOUTS ARE PROVISIONAL . FINAL LAYOUT SHALL BE DETERMINED BY THE
(n='NUMBER OF POLES', X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT', F='FUSED',) PAR D ADDRESSABLE SMOKE DUCT DETECOR
LIGHTING SWITCH INTERMIDIATE PAR PUBLIC ADDRESS RACK D CONTRACTOR FROM THE CONSTRUCTION/SHOP DRAWINGS AND AFTER COORDINATION WITH OTHER TRADES.
XA,nP,N,h,WP,F,S CEILING MOUNTED THREE PHASE DISCONNECT SWITCH, 380V ,CURRENT RATING AS INDCATED ON PLAN 6− THE SIZE OF CONDUITS AND/OR CABLE TRAYS IS IN GENERAL NOT SHOWN ON DRAWINGS. THE SIZE OF
ALL CONDUITS AND/OR CABLE TRAYS SHALL BE SELECTED BY THE CONTRACTOR IN ACCORDANCE WITH
3/DS xW REGULATIONS AND/OR STANDARDS AND WILL BE FUNCTION OF THE NUMBER AND SIZE OF THE RESPECTIVE
(n='NUMBER OF POLES', X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT', F='FUSED',) F ADDRESSABLE MANUAL CALL POINT
W.P LETTER (W.P) INDICATES WEATHER PROOF S CELING SPEAKER (WATTAGE AS INDICATED) F CONDUCTORS.
7− EARTH CONTINUITY CONDUCTORS SHALL BE RUN WITH ALL CIRCUITS IN ACCORDANCE WITH
UPS UPS UN INTERRUPTIBLE POWER SUPPLY SPECIFICATIONS,REGULATIONS AND/OR STANDARDS.
xW ADDRESSABLE MONITOR MODULE
SW MM MM
WALL SPEAKER (WATTAGE AS INDICATED) 8− ALL SURFACE MOUNTED OR RECESSED PANELBOARDS SHALL BE INSTALLED WITH THEIR TOP END AT
180cm ABOVE FFL UNLESS OTHERWISE INDICATED.
XA,nP,N,h,WP,F SWITCHED ELECTRICAL CEILING OUTLET COMPLY WITH 250 FLIXBLE AS PER OPERATING CONSTRUCTIONS.
EARTHING &LIGHTNING SYSTEM
EO 9− LAMPS SHALL BE FURNISHED AND INSTALLED IN ALL LIGHTING FIXTURES SHOWN ON THE DRAWING
(n='NUMBER OF POLES', X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT', F='FUSED'). CM CM ADDRESSABLE CONTROL MODULE
HR HORN SPEAKER (WATTAGE AS INDICATED)
B.N SYMBOLS DESCRIPTIONS 10− IN THE ABSENCE OF ANY INDICATION ON THE DRAWINGS (ARCHITECTURE OR INTERIOR) OR
POWER OUTLET COMPLY WITH BACK BOX (20X20) AS PER OPERATING CONSTRUCTIONS. INSTRUCTIONS ON SITE,MOUNTING HEIGHT OF OUTLETS OR DEVICES A.F.F.L SHALL BE AS FOLLOW:−
XA,nP,N,h,WP,F −CONVENIENCE OUTLETS 400 mm
C IP
EARTHING INSPECTION PIT & CONCRETE COMPLETE WITH CLADE PO
(n='NUMBER OF POLES', X='CURRENT RATING', E='EMERGRNCY', U='UPS', WP='WEATHER PROOF' , h ='HEIGHT', F='FUSED'). ZM ZM ADDRESSABLE ZONE INTERFACE MODULE −LIGHTING SWITCHES 1200 mm C
WITH COPPER GROUNDIN ROD20MM X 3600MM LONG MIC MICROPHONE OUTLET −SOCKETS IN TOILETS, KITCHEN,
SERVICE ROOMS AND WORKSHOPS 1200 mm
PEB POTENTIAL EQUALIZATION BUS BAR
3NO. SINGLE PHASE MCB WITH EARTH LEAKAGE CIRCUIT BREAKER WP db 11− SWITCHING ON CIRCUITS CONTAINING SWITCH SHALL BE DONE IN THE UNGROUNDED CONDUCTOR.
CB FIRE ALARM SIREN (db: SOUND LEVEL)
HN
MIC WIRELESS MICROPHONE
CADWELD CONNECTION 12− THE COLOR CODE FOR A FOUR WIRE CIRCUIT IS − ONE BLACK, − ONE RED, ONE BLUE AND ONE YELLOW
CC
ANY CONDUCTOR INTENDED FOR GROUNDING PURPOSE SHALL BE GREEN WITH YELLOW STRIPE.
INDICATION TO FOUNDATION EARTHING NETWORK T TIMER WP db,cd 13− THE CONTROL AND/OR SWITCHBOARDS FOR THE DIFFERENT SYSTEMS SUCH AS THE AIR CONDITIONING
FEN HN FIRE ALARM SERIN WITH STROBE (db: SOUND LEVEL, CD: CANDELA RATING) EQUIPMENT MACHINES, .....ETC. WILL BE IN THE SCOPE OF SUPPLY OF THE SYSTEM SUPPLIER. THE
VC VOLUME CONTROLLER
ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLING THE CABLE FEEDERS
AIR TERMINAL LIGHTNING PROTECTION TO THESE BOARDS HOOKING UP OF EQUIPMENT WILL BE THE SYSTEM SUPPLIER RESPONSIBILITY.
AT
PHC PHOTO CELL 14− IN THE ABSENCE OF ANY INDICATION ON THE DRAWINGS, BOQ THE SPECIFICATIONS, THE
CSK CALL STATION KEYPAD
FACP FACP FIRE ALARM CONTROL PANEL
INSTALLATIONS SHALL BE DONE TO THE SATISFACTION OF THE ENGINEER.
DOWN CONDUCTOR
DC
1-THE DEFAULT HEIGHT FOR ALL ELECTRICAL FIXTURES EQUAL 400mm FROM F.F.L IF IS NOT MENTIONED WITH ('h1','h2','h3','h4','h5','h6','h7','h8','h9'). 15− THE CONTRACTOR SHALL PROVIDE ALL IRON ANGLES,AND FIXING ACCESSORIES REQUIRED FOR
2- THE HEIGHT (h1=1200mm, h2=1300mm, h3=1800mm, h4=2200mm, h5=300mm, h6=400mm, h7=900mm
, h8=1850mm, h9=2600mm) FROM F.F.L P LIGHT CURRENT POLE
FARP FARP FIRE ALARM REPEATER PANEL COMPLETE INSTALLATION OF LIGHTING FIXTURES, CABLE TRAYS AND THEIR ELECTRIC OUTLETS AND
CONDUITS.
3- ALL ELECTRICAL FIXTURES ARE FEED FROM NORMAL CIRCUITS IF IS NOT MENTIONED WITH ('E' OR 'U').
.
16− FOR EXACT LOCATION AND TYPE OF EXTERIOR LIGHTING ELECTRICAL OUTLETS REFER TO LANDSCAPE
SATELITE FIRE ALARM CONTROL PANEL
SC COLUMN SPEAKER (WATTAGE AS INDICATED)
SFACP
SFACP DWG’S.
17− ALL DISCONNECT SWITCHES FOR FAN COIL UNITS TO BE CONSIDERED AS OUTLETS AND TO BE
INSTALLED ABOVE FALSE CEILING. 03
CFACP CFACP CONVENTIONAL FIRE ALARM CONTROL PANEL
18− ALL CABLES RUN ON ROOF MUST BE INSTALLED ON CABLE TRAY WITH COVER.
02
19− ALL DB SHALL HAVE AT LEAST 20% SPARES AND 10% SPACE.
SC
C
CONVENTIONAL FIRE ALARM SMOKE DETECTOR 20− ALL ELEC PANELS SHALL BE MOUNTED IN LOCKED CABINETS WITH SUITABLE SIZES. 01
S
21− THE CONTRACTOR MUST BE SUBMIT ALL SHOP DRAWING PLANS FOR APPROVAL BEFORE ANY SUPPLY &
03
BT BL
BEAM DETECTOR (TRANSCEIVER/ REFLECTED LENSE) EXECUTION.
B 02
22− FINAL LOCATIONS OF SOCKETS AND FLOOR BOXES WILL BE AS PER FINAL APPROVED FURNITURE
01
:
B B
:
:
:
:
SHEET SIZE - ISO A1 (594 * 841 MM)

:
‫ﺑ ﺩﻭﻥ‬
‫ﺟ ﺩﻭﻝ ﺍﻟ ﺭﻣﻭﺯ‬
A 1658 SCC-TC-E-100 A
1 2 3 4 5 6 7 SCC COPYRIGHT
THIS DRAWING AND THE DESIGN IT COVERS ARE THE PROPERTY OF THE SABBOUR CONSULTING COMPANY .

You might also like