Life of A Landfill Pump
Life of A Landfill Pump
Geotechnical Instruments
Environmental Products
Reliable
SIMPLY
RELIABLE
Few parts
Simple design
Innovative Features
Stainless Steel
Discharge Posi-Seal Pump Body
Check Valve Air Valve .065 Wall
Ebonite,
Bottom Dome
Hi-temp 250°F,
Inlet Assembly
Non-porous Float
Easy to Disassemble
Click in White Area to Play Movie
Control
Rod
Posi-
seal
Air valve
SRX LP Air Valve
Posi-Seal air valve provides a bubble-tight seal
preventing leakage that can lead to
unnecessary precipitation .
The air/exhaust valves can be totally accessed
without taking the pump apart – no special
tools are required.
Simply unthread.
SRX LP Fluid Discharge Check
Control
Rod
Pulse Counter
2” or 3”
Well Head
Water
Level Port
Zinc Anode
THE WEIGHT OF THE ATMOSPHERE OR GAS
INSIDE THE PUMP IS THE SAME AS OUTSIDE.
OUT IN
DISCHARGE ACTIVATION
LIQUID LEVEL
When the exhaust port and the well are open to atmosphere or
when the exhaust line is inside the well the liquid level inside
the pump to start the discharge cycle is as shown. The gas
pressure inside the pump and outside the pump are the same.
Only the higher liquid level outside the pump will cause it to fill
to the cycle activation level
The well flange seals the top of the well and all the tubing
penetrations the pump exhaust tubing is open to the atmosphere
NEW ACTIVATION
LIQUID LEVEL 0UT SIDE
IN SIDE
THE NEW ACTIVATION IS Z IN
INCHES
OF WATER + THE ORIGONIAL
SET POINT.
ORIGONIAL
LIQUID
ACTIVATION
LEVEL
When the exhaust port is open to the atmosphere and the well
is under partial vacuum the liquid level in the casing to fill the
pump and activate the discharge cycle will be increased by the
applied vacuum.
EQUALIZATION EXHAUST VALVE
Exhaust valve
3/8” push to
connect tee.
Cut the 3/8”
DGSI nylon
pump air
supply tube
above the well
seal and insert
½ Inch push to connect tube tee
fitting Muffler due
Attach to ½” O.D. DGSI not block Air venture vacuum
bundled exhaust tube open end pump
outside well seal
Common Questions
Q - How deep can I install the pump
A - Pumps are rated for 100 PSI so that
translates to 231 ft
Q – After I have had the air supply turned
off to the pump it seems to take a while
before it starts cycling properly
A – With the air supply turned off the
float moves to the on position allowing
the liquid to fill the air line therefore air
has to purge the liquid from the air
supply
Common Questions
Q – Why is liquid discharging from
the air exhaust line
A – This is normal after the air
supply has been shut off. The
liquid will fill the exhaust line
equal to the static well level. The
discharge should stop after 10-
15 cycles