Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1 MYOPIA

5 CARE
2
3

A PRACTICE- 4 6

BUILDING
7
5
8

OPPORTUNITY: 1 Forehead rest 5 Stand-by button 6 LCD display


2 Placido disk Power connector with touchscreen
(with fuse carrier)
3 Chinrest
Chinrest motor
2 x USB port
1 x LAN port
7
8
Joystick
Locking screws
BECOME THE REFERENCE
With myopia on the increase, 4

your practice is likely to see more IN MYOPIA CARE. NATURALLY.


and more myopic patients
seeking long-term solutions. 

Generate new business


TECHNICAL SPECIFICATIONS
by engaging the whole family
with Myopia Expert 700 MEASUREMENT SPECIFICATIONS
and the Essibox Myopia Care. Axial length Low coherence interferometry
Together they form the Expert Corneal topography and keratometry:
Myopia Care solution, an - Keratoscopic cone 24 rings equally distributed on a 43D sphere
advanced Myopia Management - Analyzed points Over 100,000
service within the Essilor patient - Measured points Over 6,000
journey – from anamnesis to - Corneal coverage Up to 9.8 mm on a sphere of radius 8mm (42.2 diopters with n = 1.3375)
the eye exam, refraction to - Focus system Guided focus
Pupillometry Infrared LEDs + white LEDs for photopic pupil acquisition
prescription, to dispensing – that
Fluorescein Blue LEDs with barrier yellow filter
allow you to grow your practice.  

MEASUREMENT RANGE AND ACCURACY


Keratometry Curve radius – Range: 5.00 – 12.00 mm – Resolution: 0.01 mm – In vivo repeatability: ±0.02 mm
TO INCREASE Curve radius in diopter (D)(n=1.3375) – Range: 28.00 – 67.50 D – Resolution: 0.01 D –
In vivo repeatability: ±0.12 D
CAPTURE RATE Axial length Range: 15.00 – 36.00 mm – Resolution: 0.01 mm – In vivo repeatability: ±0.027 mm
Attract customers by positioning Pupil dimension Range: 0.50 – 10.00 mm – Resolution: 0.01 mm – In vivo repeatability: N/A
your store as an expert center Limbus (white-to-white) Range: 8.00 – 14.00 mm – Resolution: 0.01 mm – In vivo repeatability: ±0.05 mm
in myopia.

TO EXPAND IN-STORE ENVIRONMENTAL CONDITIONS

ESSILOR INTERNATIONAL © - R.C.S Créteil 439 769 654 - Réf: M01460-01-en-Brochure Myopia Expert 700
Temperature In use: 10° C to 40° C – Storage: -20° C to 70° C – Transport: -20° C to 70° C
TRAFFIC
Relative humidity In use: storage and transport: 8 – 75% (non condensing)
Increase repeat business
Atmospheric pressure In use: 800-1060 h Pa – Storage: 700-1060 h Pa – Transport: 700-1060 h Pa
thanks to regular monitoring.

TO IMPROVE OTHER SPECIFICATIONS


PRODUCT MIX Electrical specs Power supply: AC 100-240V 50/60 Hz – Power consumption: 100 VA – Fuse - Type: 20 x 5 mm -
Value: T 2.5 A L 250 V anti-surge
Generate revenue from Mechanical specs Width: 320 mm – Height: 490 mm – Length: 470 mm – Weight: 18 kg
premium frames, lenses PC specs Operating system: WINDOWS 10 – Processor: Intel® Celeron® DC N 3350 – RAM: 4GB –
and solutions. Hard disk: At least 500GB – External connections : LAN integrated, 2x USB

TO BUILD LOYALTY 0123

Inspire confidence in the patient


and parents thanks to easy-to- This is a medical device MDD class IIa. Legal manufacturer : Visia Imaging S.r.l. For professional use only. Read attentively instructions for use.
understand charts and analysis
that show results clearly and
point to next steps. ESSILOR INTERNATIONAL EXPERT MYOPIA CARE
Division Instruments
147 rue de Paris
94220 Charenton-le-Pont
France
Tél. : +33 (0)1 49 80 62 80
www.essilor-instruments.com
EXPERT MYOPIA CARE

NATURALLY BECOME AN BUILD THIS EXPERTISE EFFECTIVELY SHARE YOUR


EXPERT IN MYOPIA CARE ON AN EASY TO ADOPT EXPERTISE WITH CUSTOMERS,
SOLUTION CREATING A STRONG IMPACT
AND BUILDING LOYALTY
Being an expert is not easy: myopia
management requires a lot of Immediate connection of all your
expertise and careful analysis instruments through an intuitive Create long term trust and
of many parameters. Essilor interface that is extremely simple to engagement with your patients
Instruments brings a scalable and operate even by less experienced using the Essibox Myopia Care
professional protocol to your practice practitioners. application and Myopia Passport.
for effective and proactive myopia
management from the early detection Straightforward result interpretation Guide your patients through
to long term monitoring. with a dashboard combining all every step of their myopia journey
relevant myopia data (anamnesis, by explaining clinically meaningful
For each child, identify all myopia objective and subjective refraction, results in a straightforward way
risk factors from genetics to axial length and topography) thanks to an educational, patient-
environmental and behavior with a from different instruments (WAM, friendly / easy to understand
comprehensive anamnesis following Vision-R, Myopia Expert 700) at your interface. KEY
the International Myopia Institute fingertips.
guidelines. Engage your patients in long-term FIGURES
Easy to create a standardized myopia myopia control to achieve the best

SET YOURSELF APART AS THE REFERENCE MYOPIA CARE CENTER,


Systematically and automatically patient flow that can be operated outcome for their vision, maximizing ON MYOPIA(1)
detect myopia onset combining through delegation. satisfaction and creating long
refraction data from AKR, WAM, term loyalty.
CAPTURING THE GROWING MYOPIA OPPORTUNITY AND PROVIDING Vision R/S by comparing these to Peace of mind with smooth patient
SUPERIOR SERVICE TO YOUR PATIENTS. normative data to trigger the relevant monitoring, QR-Code based GDPR Leave your patients and their 2.5 billion
myopia control. compliant solution. family confident with the results. suffer from myopia today
Let your patients spread the word
Monitor myopia evolution with Myopia care made easy for you. about the personalized care and
Driven by the growing prevalence in myopia and new control axial length and complement the All the expertise at your fingertips. Myopia Passport.
solutions, more and more families are seeking effective efficiency of the control solution 5 billion
professional myopia care. easily with Myopia Expert 700 and Communicating your expertise will suffer from myopia
display these data against global eye has never been more effective. by 2050
Only experts will create trust - essential to capture the myopia growth data.
opportunity. Become a reference myopia care center to attract
patients and their family and to better serve your customers. The Myopia Expert 700 with its digital Visualize all relevant data and
solution Essibox Myopia Care offers you parameters on a simple dashboard 1 billion
Set yourself apart with the best-in-class, comprehensive a highly accurate, turn-key resource that to prescribe the best myopia people will have high
myopia care solution including instruments, protocols, digital enables proactive myopia management. management solutions. myopia by 2050
application and clinically proven lenses.
Don’t stop at being an expert -
be the reference.
YOU PROBABLY KNOW… …BUT DID YOU KNOW?
- Accurate visual correction based on - International Myopia Institute recommends a
refraction is important but not sufficient for myopia follow-up exam every 6 months(2).
slowing down progression of myopia. - Between 2 follow-up exams, the typical axial
 1.Holden BA, Fricke TR, Wilson DA,
-M  yopia Management, comprising regular length growth of a European child is 60 µm(3).
et al. Global Prevalence of myopia
monitoring and myopia-specific solutions, is But a standard refraction with cycloplegia and High myopia and Temporal Trends
the ONLY way to slow down the progression only reaches 100  µm(4,5). from 2000 through 2050. Ophthalmology.
of myopia. -T he Myopia Expert 700 is accurate to 27 µm 2016;123(5):1036-1042.
-T  he earlier myopia is controlled, the less likely giving you the precision you need for effective doi:10.1016/j.ophtha.2016.01.006

it is to become more severe(1). Myopia Management.

1. Myopia Prevention, Early Detection, myopiaprevention. com.au/early-detection/ 2. IMI– Clinical Management Guidelines Report, Gifford et al. 3. Axial length
growth and the risk of developing myopia in European children - Jan Willem Lodewijk Tideman et al. 4. Comparison of predicted and measured axial length for
ophthalmic lens design, Hyeong-Su Kim et al. 5. Accuracy of noncycloplegic refraction in primary school children in southern Thailand, Panrapee Funarunart.

You might also like