1 CFBC means
A.) Circulating Fluidised Bed Combustion
B.) Circular Fire Ball Combustion.
C.) Circular Fire Bed Combustion.
2 ESP means
A.) Electrostatic Precipitator
B.) Electrical Supply System
C.) Electronic System of Power
3 Ash is being handled at SLPP these days
A.) Only in wet form
B.) Only in dry form
C.) Both wet & dry handling
4 SLPP power is being exported to
A.) GEB grid
B.) Surat grid
C.) Baroda grid
5 Raw water required for SLPP is being drawn from
A.) Narmada river
B.) Tapi river
C.) Tadkeswar irrigation canal
6 Lime required for SLPP boilers is being mined from
A.) Vastan mines
B.) Tadkeswar mines
C.) Purchased from outside
7 Lignite required for SLPP boilers is being mined from
A) Vastan mines
B) Tadkeswar mines
C) Purchased from GMDC
8 Generating capacity of SLPP units is
A.) 125 mus each
B.) 125 KW each
C.) 125 MW each
9 CFBC boilers of SLPP does not have
A) mills for grinding lignite
B) mills for grinding lime
C) mills for grinding lime & lignite
10 Prime fuel being used in SLPP boilers is
A) HFO
B) Lignite
C) Lime
11 PLF means
A) Plant Load Factor
B) Plant Level Factor
C) Power Load Factor
12 After passing through sequence - HP Turbine -IP Turbine - LP Turbine,
the Steam enters into :
a) Generator
b) Condenser
c) Flash Tank
15 In air and flue gas duct, the flow measurement is done by using
(a) Orifice plate
(b) Ventury Tube
(c) Aerifoils
28 For level measurement using differential pressure method, vapour balance line is required, if tank is
(a) Open tank
(b) Closed tank
(c) Both of above
29 For measuring gas flow using orifice, the pressure tappings are taken from
(a) Side
(b) Bottom
(c) Top
30 For transmitting low signals, which cables gives best immunity against electrical noise
(a) Twisted pair copper cable
(b) Fibre optic cable
(c) Co-axial cable
33 Which method is widely used for measuring flow of HFO fuel oil.
(a) Magnetic flowmeter
(b) Dip tube
(c) Mass flowmeter
34 Which parameter is used as feed forward for pressure control of steam from boiler.
(a) Drum level
(b) Feed water flow
(c) Steam flow from boiler
35 For operation of globe type motor operated valve, which check-backs are preferred for safety
interlocks.
(a) Use of open limit switch
(b) Use of torque switches
(c) Use of open and close limit switches & torque switches
40 Maximum allowable loop resistance for two wire transmitter working on 24V DC shall be
(a) 1000 ohms
(b) 600 ohms
(c) 250 ohms
41 For electromechanical relay, "normally open" and "normally closed" contacts are defined as
(a) De-energised condition
(b) Energised condition
(c) Latched condition
48 With two parallel resistors, one is 100 Ohm, the only likely value for net resistance is
a) 90 Ohm
b) 101 Ohm
c) 1000 Ohm