Professional Documents
Culture Documents
Gereja Perawan Maria
Gereja Perawan Maria
Piping Diagrams
Pipes marked with a short red stripe in the diagrams must be connected to the device with a reducing joint.
Out 1
RXQ24AMY14
RXQ12AY14 RXQ12AY14
½"×1⅛" ½"×1⅛"
BHFP22P100
#1.1 #1.2
⅝"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
R1
FXFQ125AV4
#1.3 #1.4
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
R1
FXFQ125AV4
#1.5 #1.6
½"×1⅛" ⅜"×⅝"
KHRP26A72T
R. 1
FXFQ80AV4
#1.7 #1.8
⅜"×⅞" ⅜"×⅝"
KHRP26A33T
R1
FXFQ125AV4
#1.9
⅜"×⅝"
R1
FXFQ125AV4
Warning: The pipe diameter values are purely indicative. Depending on the required pipe lengths, a different pipe
diameter might be required.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
12
4.2. Piping Out 2
Out 2
RXQ60AMY14
RXQ20AY14 RXQ20AY14 RXQ20AY14
#2.1 #2.2
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.3 #2.4
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.5 #2.6
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.7 #2.8
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.9 #2.10
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.11 #2.12
¾"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.13 #2.14
¾"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#2.15 #2.16
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#2.17 #2.18
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#2.19 #2.20
½"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#2.21 #2.22
⅜"×⅞" ⅜"×⅝"
KHRP26A33T
AULA
FXFQ125AV4
#2.23
⅜"×⅝"
AULA
FXFQ125AV4
Warning: The pipe diameter values are purely indicative. Depending on the required pipe lengths, a different pipe
diameter might be required.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
13
4.3. Piping Out 3
Out 3
RXQ60AMY14
RXQ20AY14 RXQ20AY14 RXQ20AY14
#3.1 #3.2
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.3 #3.4
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.5 #3.6
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.7 #3.8
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.9 #3.10
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.11 #3.12
¾"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.13 #3.14
¾"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#3.15 #3.16
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#3.17 #3.18
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#3.19 #3.20
½"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#3.21 #3.22
⅜"×⅞" ⅜"×⅝"
KHRP26A33T
AULA
FXFQ125AV4
#3.23
⅜"×⅝"
AULA
FXFQ125AV4
Warning: The pipe diameter values are purely indicative. Depending on the required pipe lengths, a different pipe
diameter might be required.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
14
4.4. Piping Out 4
Out 4
RXQ56AMY14
RXQ20AY14 RXQ18AY14 RXQ18AY14
#4.1 #4.2
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#4.3 #4.4
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#4.5 #4.6
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#4.7 #4.8
¾"×1⅝" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#4.9 #4.10
¾"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#4.11 #4.12
¾"×1⅜" ⅜"×⅝"
KHRP26A73T +
KHRP26M73TP
AULA
FXFQ125AV4
#4.13 #4.14
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#4.15 #4.16
⅝"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#4.17 #4.18
½"×1⅛" ⅜"×⅝"
KHRP26A72T
AULA
FXFQ125AV4
#4.19 #4.20
⅜"×⅞" ⅜"×⅝"
KHRP26A33T
AULA
FXFQ125AV4
#4.21
⅜"×⅝"
AULA
FXFQ125AV4
Warning: The pipe diameter values are purely indicative. Depending on the required pipe lengths, a different pipe
diameter might be required.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
15