04 GSB242BII Operation Manual

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 10

GRL8004SII Optical

Transmission Platform
GSB Series Upstream Optical Receiver

Operation Manual

Chengdu KT Electronic Hi-Tech Co., Ltd


1. Brief introduction

1.1 Description
GSB series optical receiver is standard 3RU upstream optical receiver designed for
HFC and FTTH application. RF bandwidth: 5~200MHz.
GSB series optical receiver adopts embedded microcontroller processing circuit to
monitor and control the state and remote communication of all the parameters. It can check
and configure the parameter information by accessing optical platform front panel LCD or
connecting NE8004SIIET device management module.

1.2 Feature

■Bandwidth: 5~200MHz
■Each input channel has separate AGC and MGC control mode
■MGC adjust range: 31dB
■AGC control range: -8~+2dBm, output level 100dBµV
■Under AGC mode, OMI setting is -4dB to 0dB adjustable, the output level could be adjusted.
■Hot-Swap, not affect the normal work of the other modules and module
■Excellent cooling channel design
■Short circuit protection
■Aluminum die casting shell
■The front panel level test port can switch through the key, test the RF output of each
channel
■Front optical fiber interface for easy operation and wiring
■LED lights on front panel indicate working status of the modules
■Can realize local monitor monitoring and parameter setting by LCD window and keys.
■Can remote check and set working parameters of the modules through network
management software of headend by connecting NE8004SIIET.
■Low-power design, environmental protection, low-carbon
1.3 Specification

1.3.1 Optical characteristic

Input optical wavelength 1310 or 1550nm

AGC control range -8~ to +2dBm


Output level under AGC 100dBµV
Connector type SC/APC

1.3.2 RF characteristic

Working bandwidth 5 to 200 MHz

OMI adjusting range -4 to~0dB

MGC adjusting range 31dB

Flatness ±0.75dB

Return loss ≥16 dB

Impedance 75Ω

Connector type F (Femalefemale)

Testing port(F male) -40±2dB

1.3.4 Electrical / environmental / mechanical characteristic

Power consumption ≤12W

Working temperature 0 to 50℃(32 to 122℉)

Storage temperature -40 to 70℃(-40 to 158℉)

Relative humidity Max. 85% non-condensing

Dimension 24mm Wx 129.5mm Hx 434mm D


Weight 1Kg

2. GSB series upstream optical receiver panel structure please see fig 2.1 and description
please see table 2.1

(13)

(14)

(15)

(16)

(17)

Fig 2.1 GSB series upstream optical receiver panel

Table 2.1 Function Description

Item Description Function

1 Fix screw Fix the module to chassis


2 Testing port Output RF signal testing port, F (male)
Correspond to 1~4 Green: input optical power is within normal range, default -9
3 /4/
optical input status ~+2dBm
11/12
indication Red: input optical power too high or too low
Choose the testing port of each channel by keys, the
Testing port selection correspond optical input signal status indicator flashing
5
key means the testing port is working in the corresponding
channel
6 /7/ 8/9 Optical input port In turn corresponds to the 1 to 4 channel optical input port,
default SC / APC type connectors
10 Vent The airflow entrance, for heat dissipation
13 Vent The airflow exit, for heat dissipation
Pin type connect
14 For module power supply and signal transmission
port socket
For guiding and positioning module when inserted
15 Pilot hole
into the optical platform rack
4 input: the first and second combined RF output
16 RF signal output port
2 input: the first RF output port
4 input: the third and fourth combined RF output
17 RF signal output port
2 input: the second RF output port

3. Precautions

The Manual provides for safety standards in product design, manufacture and use. If
violate these safety precautions, it may cause damage to the equipment, and KT Company
does not undertake any responsibility
Warning: Do not make the module work beyond its maximum rated working conditions. It
will lead to poor product performance and reduce module service life, even dangerous.
Warning: Do not attempt to alter or modify any part of the module which will not allow you
to get warranty service. Please return the product to KT for repair
Warning: This module working temperature is 0 to 50 º C (32 to 122 º F).
Warning: This module storage temperature is -40 to +70 º C (-40 to +158 º F) , relative
humidity is 85% (non-condensing), and away from sources of ignition and corrosive
substances.

Assemble and Disassemble


4. Install and uninstall transmitter module
4.1 AssembleInstall

1) Check pin-socket module pin type connector on the rear panel, prior to installation to
ensureand make sure that no pins are bent.
2) Insert the module in the rack along the guide slot.Alignment slot, along the guide slot
to put module into the slot of the rack.
3) Tight the screws on the front panel.
Note: The module is powered, LED lights will flash for about 2 seconds, indicating that
the module is self-test.
4) If you need to install other another module, repeat steps 1 to 3.
5) Using optical power meter to measure RF level that will be input to module, to ensure
the access RF level r is within the predetermined range
Warning: input optical signal should avoid prolonged than +2 dBm, too high input signal
will damage the laser.
6) Using suitable cable to connect to the corresponding RF IN output port on rear panel.
7) Verify that the optical fiber port and module connector are matched. Before
installation, ensure that the end face of the optical fiber and module connections is
clean.
NOTE: When using the wrong connector head, it will damage the fiber end faces and
reduce the performance of the module.
9) Connect the optical fiber to optical fiber connecter on front panel
10) Power meter measure whether the output optical power is within specifications
11) Connected to NE8004SIIET RJ45 interface via Ethernet cable, check and set various
parameters by software to ensure the accurate device parameters.
4.2 Screen captures and operation stepsOptical platform LCD window operation

4.2.1 Function interfaceScreen captures and operation steps


↓ OPTICAL PLATFORM
GRL8004SII

↑ NET SETUP
↓ → SLOT SELECT

↑ SLOT SELECT: 1

↑ SLOT 1:GSB242BII
↓ 1 OP1 POWER: -2.5dBm

↑ SLOT 1: GSB242BII
↓ 2 OP2 POWER: -2.5dBm

↑ SLOT 1: GSB242BII
↓ 3 OP3 POWER: -2.5dBm

↑ SLOT 1: GSB242BII OK SLOT 1: GSB242BII


SLOT 1: GSB242BII
↓ 4 OP4 POWER: -2.5dBm 5 AGC 【MGC】 5.1 OPT1: ATT 【20dB】
← ↑↓

↑ SLOT 1: GSB242BII
↓ SLOT 1: GSB242BII
5 OP1 : 【AGC】 MGC ESC
5.1 OPT1:ATT 【9dB】

↑ SLOT 1: GSB242BII
↓ 6 OP2 : 【AGC】 MGC

↑ SLOT 1: GSB242BII
↓ 7 OP3 : 【AGC】 MGC

↑ SLOT 1: GSB242BII
↓ 8 OP4 : 【AGC】 MGC
SLOT 1: GSB242BII ↑
OK 9 OMI1 : 0dB ↓
↑ SLOT 1: GSB242BII
↓ 9 OMI1 : 0dB OK

↑ SLOT 1: GSB242BII
↓ 10 OMI2 : 0dB

↑ SLOT 1: GSB242BII
↓ 11 OMI3 : 0dB

↑ SLOT 1: GSB242BII
↓ 12 OMI4 : 0dB

↑ SLOT 1: GSB242BII
↓ 13 DC 22V: 22.0V
↑ SLOT 1: GSB242BII
↓ 14 DC +5V: 5.0V

↑ SLOT 1: GSB242BII
↓ 15 Slot temper:35℃

ok ←→ SLOT 1: GSB242BII ESC


↑ SLOT 1: GSB242BII SLOT 1: GSB242BII

˂ 16 Slot reset 【OK】 16 Slot reset
16 Slot reset

ok ←→ ESC
↑ SLOT 1: GSB242BII SLOT 1: GSB242BII SLOT 1: GSB242BII
↓ 17 Factory reset 17 Factory reset 【OK】 17 Factory reset

4.2.2 Operation instructions

1 ) When the module is properly inserted in the slot, press the platform "↓" key to lit LCD,

press "↑" or "↓" key to enter the slot selection menu to choose Select function module slot

items "SLOT SELECT", press OK to confirm; Then press"↑" or "↓" key, you can choose the

slot that the module inserted, and press OK to access the module information menu.

Upstream optical receiver module menu includes 17 primary menus, the user can use "↑" or

"↓" key to cycle through each menu, menu users can easily check the various important

parameters associated with the module. AGC / MGC menu, OMI menu, Slot reset menu,

Factory reset menu can set the parameter menu.

2)AGC/MGC menu setting: is used for setting working mode of RF of module.

The operation is as follows: press "↑" or "↓" key to select to AGC or MGC (small display box

is checked to live the choice of AGC / MGC), press "OK" to complete the AGC or MGC

option. MGC mode user can decrease or increase the excitation level by "↑" or "↓" key.

Under MGC mode, Laser excitation level will change according to the input level change,

and the system level will change accordingly. Therefore, the user is recommended to use

AGC mode, the MGC mode is only used for a special case.
3)OMI menu settings; This menu is used to output level adjustment under AGC working
mode. The factory default OMI is 0dB, you can fine-tune the output according to system
requirements, adjust range -4~0dB.
The operation is as follows: when the menu is displayed, press the "OK" button, when cursor
flashes on the display level to enter modify state; continue to press the "˅" or "˅" key to
decrease or increase the output optical power; Press OK to confirm settings completed.
4)Slot reset menu setting: the menu is used for module reset restart, the parameter will not
be changed after the reset. The operation is as follows: when the menu is displayed, press
the "OK" button, enter the reset confirmation menu, press the "OK" button to restore
automatically returned to reset menu after the restart completed.
5)Factory reset menu: This menu is used to restore module parameters, set the parameters
to the factory setting parameter module when reset is complete. Mainly used when system
parameter can not continue normal use after the users debug parameters.
The operation is as follows: when the menu is displayed, press the "OK" button to enter the
restore factory settings confirmation menu, then press the "˂ ˃" to reset module. It will restore
to factory settings after restart.
4.3 Uninstall optical receiver moduleDisassemble

1)Remove optical fiber connector from front panel, and immediately covered with dust cap
of the fiber optic module joints
2)Remove the radio frequency signal lines from the back panel.

3) Loosen the screws on the front panel of the module


Warning: loosen the screws on front panel and gently pull the module.
4) Withdrawn the module

6. Troubleshooting
This chapter describes the module maintenance and troubleshooting information. Only qualified
personnel can carry out such work. Module failure, STA status displays in red, indicating failure. You can
press"↑" or "↓" and "OK" button to check the failure. You can also view and set the module operating
parameters via network management software of PC side.
Fault/IndicationFault Check/Suggested ActionMaintenance
Optical input channel 1. Ensure the input optical power is within threshold
responding to P1-P4 2. If input optical power is normal, please contact manufacture
is red to maintenance

1. Clean optical fiber connector and end faces


2. Use optical power meter to measure input optical power
3. Use manual gain to adjust the output RF signal level
No RF signal output
4. Measuring the signal strength of the RF output port
5. If still no RF output, please contact manufacture to
maintenance

1. Ensure all connecters are clean


2. Use the correct connector
RF signal output level
3. Ensure the optical input power is within the predetermined
is lower than
range
specification
4. Adjust RF output attenuation
5. Measuring RF output signal
6. If the output level is still lower than specification, please
contact manufacture to maintenance

Danger / warning: In any case, do not open the module enclosure, open module housing may

damage equipment and make you cannot get warranty service.

Chengdu KT Electronic Hi-tech Co., Ltd


Add: No.9, 3rd East Wuke Road, Wuhou District, Chengdu Zip code: 610045
Tel:( 86-028)-85360759 Fax:(0 86-28)-85369640
Email:oversea@ktcatv.com http://www.ktcatv.com

You might also like