WATO EX-30
Anesthesia Machines

Model Selections
Input voltage I00 to 120 V I00 to 240 V I20 to 240 V
Input current 8.5 to 3.5 A 8.5 A 3.5 A Technical Specifications (Ver. 2016-09-13)
Input frequency 50/60 Hz
Leakage current < 500μA Physical Specifications

Fuse T10 AL/250V Dimensions And Weight


Power cord 5m Height: 1375 mm
Auxiliary output supply Width: 710 mm (without breathing circuit)
Output voltage 220 to 240 V 100 to 120 V 880 mm (with breathing circuit)
Output frequency 50/60 Hz 50/60 Hz
Depth: 620 mm
Output current(outlet 1) 1.6A 3.8A
Weight: <120 kg (including trolley base, without
Output current(outlet 2) 0.5A 1.0A
Output current(outlet 3)
vaporizer and cylinder)
0.5A 1.0A
Fuse(outlet 1) T 3.0AL/250V T6.3AL/250V Top Shelf
Fuse(outlet 2) T1.6AL/250V T1.6AL/250V Weight limit: 30kg
Fuse(outlet 3) T1.6AL/250V T1.6AL/250V Length: 550mm Timer: Time of operation will be displayed on
Width: 265mm the screen
Ventilator Specifications

Work surface Standby Mode


Inlet and Outlet Modules Machine i Standby Mode: s on call; System settings,
Height: 820 mm
3 outputs: without separate transformer, include: ventilation and alarm parameters can be set
Width: 500mm
Type Area Input power 3auxiliary output
Depth: 310mm Mode of Ventilation
Europe
Volume-Controlled Ventilation (VCV) with tidal volume compensation
UK DIN Rail
With no isolated 100-240V~ 6.2-2.6A 50/60Hz 100-240V~ 1.2-0.6A 50/60Hz
Pressure Mode Ventilation (P-mode)Mannual
India
Side of machine: 320mm
transformer US(B type) Ventilator Parameter Ranges
Australia Drawer--internal dimensions Tidal volume range: 20~1500 mL (increments of 1 mL) (Volume Mode)
US 100-120V~ 5.6A 50/60Hz 100-120V~ 1.2A 50/60Hz 5~1500 mL (increments of 1 mL) (Pressure Mode)
Height: 240mm
Europe
Incremental settings: 20~100ml (increments of 5 ml)
Width: 350 mm
UK
100~300 ml (increments of 10 ml)
India Depth: 275mm
With isolated tranformer 220-240V~ 2.7A 50/60Hz 220-240V~ 0.6A 50/60Hz 300 ~1500 ml (increments of 25 ml)
US(B type) Bag arm
Australia
Pressure (inspired) range: 5 ~ 60 cmH2O
Height: 1030mm
US 100-120V~ 5.6A 50/60Hz 100-120V~ 1.2A 50/60Hz increments of 1 cmH2O
Length: 320mm
Pressure (limit) range: 10~100 cmH2O
Connection: ISO 22mm OD, 15mm ID
increments of 1 cmH2O

Casters Rate range: 4~100 bpm

Diameter: 125 mm increments of 1 bpm (VCV, P-mode)

Brakes: two of four casters 4~60 bpm


Increments of 1bpm (SIMV)
Screen
Inspiratory/Expiratory ratio (I:E) range: 4:1~1:8
Display type: Color active matrix TFT
increments of 0.5 (VCV, P-mode)
Display size: 8.4 in diagonal
Inspiratory pause time: OFF,5~60% of inspiratory time
Resolution: 800×600
Increments of 5%.
Brightness: Adjustable
Trigger window: 5-90%
Multi-display selectable: Standard
Increments of 5% (SIMV)
Display Parameters: All settings and alarm parameters(Breath rate,
Flow trigger: 0.5~15L/min
P/N:ENG-WATO EX-30 datasheet-210285x4P-20160914 I/E ratio, tidal volume, minute volume, PEEP,
Increments of 0.5L/min (SIMV)
Pmean Ppeak, Pplat and O2concentration, )
Pressure tigger: -20~ -1cmH2O
Display Graphics: Waves of Pressure-Time, Flow-Time, Volume-
Increments of 5% (SIMV)
Time, Wave of CO2 (Optional);
NEW
TM
WATO EX-30
Anesthesia Machines
Positive End Expiratory Pressure (PEEP) Continuous trend information together with time discrete events are Indicator: flow tube ±5% of reading (41 ~ 76 mmHg)
Type: Integrated, electronically controlled stored and shown by table for the latest 24 hours for TVe, Ppeak, MV, ±10% of reading (77 ~ 99 mmHg)
Range: OFF, 4 ~30 cmH2O Hypoxic Guard System Resolution: 1 mmHg
Pplat, PEEP, Pmean,Rate and optional FiO2, EtCO2,
increments of 1 cmH2O Type : Mechanical Gas compensations: N2O, O2 and Anesthestic Gas (only for Desflurane)
Resolution: 30s,1min, 2min ro 4min optional
Range : Provides a nominal minimum 25% compensation, optional
Ventilator Performance New trend form will be recorded when restart the machine Humidity compensation: BTPS or ATPD
concentration of oxygen in O2/N2O mixture
Pressure range at inlet: 0.28~0.6 MPa BTPS: Body Temperature and Pressure, Saturated Gas
Vaporizer
Peak gas flow: 100 L/min + Fresh gas O2 Controls ATPD: Ambient Temperature and Pressure, Dry Gas
Type: Penlon Sigma Delta or Sigma Alpha vaporizer, options include
Flow valve range: 1 to 100 L/min Method: N2O shut off with loss of O2 pressure Sampling rate: 70 or 100ml/min
Desflurane, Isoflurane, Enflurane, Sevoflurane, Halothane vaporizer
Supply failure alarm : <200 kPa Sampling rate accuracy: 0.15% or 15ml/min whichever is larger
Position of vaporizer: one or dual-positions
Ventilator Accuracy
Installation mode: selectatec® with interlock Start-up time: less than 1min. The module enters the warming
O2Flush : 25~75 L/min
Delivery/ monitoring accuracy
up status after the startup
Volume delivery: < 75 ml, ±15ml
Electrical Specifications Breathing Circuit Specification 10minute later, it enters the Full accuary mode
≥75 ml, ±20ml or ±10%, whichever is larger
Current Leakage Operational Modes: closed and semi-closed circuit system Delay time: When measured with a neonatal watertrap and
Plimit: ±4.0 cmH2O, or ±10% ,whichever is larger
100~240V < 500 μA Volume of CO2 canister: about 1500 mL a 2.5m-long
PEEP delivery: ±2.0 cmH2O, or ±10% ,whichever is larger
Water Trap: 6mL, easy to be disassembled neonatal sampling line: <3 s @ 100 ml/min
Volume monitoring: < 75 ml, ±15ml Power and Battery Backup
Port and Connectors: <3.5 s @ 70 ml/min
≥75 ml, <1500 mL, ±20ml or ±10%, whichever Power input: 100-240 Vac, 50/60 Hz, 3.0~2.6A
Inspiration/ expiration connector: 22 mm OD and 15 mm ID conical When measured with an adult watertrap and a
is larger Battery backup: 90 min for 1 piece battery (powered by new
connector 2.5m-long adult sampling line:
> 1500mL unspecified fully-charged batteries with 25℃ ambient
Manual bag port: 22 mm OD and 15 mm ID conical connector <5 s @ 100 ml/min
Pressure monitoring: ±3.0 cmH2O, or ±8% ,whichever is larger temperature)150 min for 2 piece battery
System Pressure Gauge: <6.5 s @ 70 ml/min
(powered by new fully-charged batteries
Range: -20~100 cmH2O Alarm limit: EtCO2 high: (low limit+2) to 99mmHg
Alarm Settings with 25℃ ambient temperature)
Accuracy: ±2.5% full scale EtCO2 low: 0 to (high limit-2) mmHg
Tidal volume(expiratory):High: 5~1600 ml Battery type: build-in Li-ion battery, 11.1 VDC, 4400 mAh
Bag/Mechanical Ventilation Switch: FiCO2 High: 0 to 99mmHg
Low: 0 ~1595 ml Number of batteries: 1or 2 pieces
Type: Bi-stable Increments of 1 mmHg
Minute volume(expiratory): High: 0.2 ~100L Time to shutdown: 5~15 min (powered by new fully-charged
Control : the switch between manual ventilation and
Low: 0 ~99 L batteries after the first low-power alarm) Anesthetic gas scavenging system
ventilator
Inspired oxygen: High: 20~100% Charge time: Approximately 8 hours (in running status or Active AGSS:
Low: 18 ~ 98% standby mode) Adjustable Pressure Limiting (APL)valve Size: 443 x 145 x 140mm (height x width x depth)
Low airway pressure: 0 ~98 cmH2O Power cord: 5m Range: 1~75 cm H2O Type of disposal system: High-flow disposal system
High pressure: 2~100 cmH2O Tactile knob indication at: >30 cm H2O Applicable standard: ISO 8835-3: 2007
Pneumatic Specifications
Apnea alarm: 20s Accuracy: ±10cmH2O Pump rate: 50 to 80 L/min
Switching Auxiliary Common Gas Outlet(ACGO)
Ventilator Monitoring Start pressure: 1cmH2O Pressure relief device: Pressure compensation opening to the air
Connector: ISO 22 mm OD and 15 mm ID
Minute volume range(expiratory):0~100 L/min Filter: Stainless screen with hole diameter of 140~ 150μm
The outlet locates at the inspiratory limb Breathing Circuit Parameters
Tidal volume range(expiratory):0~1500 ml State indication of the disposal system: The float falls below the
Compliance: ≤4mL/100Pa
Inspired oxygen(FiO2): 18~ 100% Gas Supply “MIN” mark on the sight glass when the disposal
Automatically compensates for compression system does
Peak pressure : -20~120 cmH2O Pipeline input range: 0.28~0.6MPa losses within the breathing circuit in not work or the pump rate is lower than 50 L/min.
Mean pressure: -20~120 cmH2O Pipeline connections: NIST, DISS mechanical mode Connector of the disposal system: BS6834-1987 standard connector
Plateau pressure: -20~120 cmH2O Cylinder input: PISS, Maximum 2 cylinders, optional Expiration resistance: < 6 cm H2O @60 L/min
Sweep speed: 12.5 or 6.25 mm/s Primary regulator nominal output: 207kPa Inspiration resistance: < 6 cm H2O @60 L/min Environment specification
Positive End Expiratory Pressure (PEEP): 0~30 cmH2O Mechanical control flow meters Material: The material contact with exhaled gas is Operation conditions
O2 range: two flow tubes with the ranges of 0 ~1L/Min autoclavable and natural latex free , Temperature: 10~40℃
Trend Chart
and 10 L/min except flow
Continuous trend information together with time discrete events Relative humidity: 15~95%(noncondensing)
N2O range: two flow tubes with the ranges of 0 ~1L/Min sensors , O2 fell cell and mechanical
are stored and shown by lines for the latest 24 hours with 5 seconds Barometric (KPa): 70~106 kPa
and 10 L/min pressure meter.
resolution for Tve, Ppeak, MV, Pplat, PEEP, Pmean,Rate and optional
Air range: two flow tubes with the ranges of 0 ~1L/Min Storage conditions
and 10 L/min Gas Monitoring Temperature: -20~60℃ for main unit, -20~50°for O2 sensor
FiO2, EtCO2。
Accuracy: <±10% of indication Mindray Side-stream Carbon Dioxide (CO2) Module Relative humidity: 10~95% (noncondensing)
New trend chart will be recorded when restart the machine
Auxiliary O2 Flowmeter (Optional) Measurement range: 0 ~ 99 mmHg Barometric (KPa): 50~106 kPa (optional Artema Multi-Gas
Trend Table Range: 0 ~15L/min Accuracy : ±2 mmHg (0 ~ 40 mmHg) module:70~106 kPa)