Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

A B C D

3
4 " Ø G.I WATER RISER

12.00
4.00 4.00 4.00 3
4 " Ø G.I WATER RISER PIPE TO WATER TANK

2.50 1.00
1 " Ø G.I WATER BRANCH PIPE
2

GV

1.00
R

2.00
O.T
R

1.00
R CV
R GV

3
Hb

2.00
5.00

5.00
2.00
SV

12.00
AV
10.00

2.00
2

AC

1.00
2.00

2.50
5.00

Hb
2.00

1.50
AV SV
1

AC
Hb

CV

M
GV GV

1
" Ø G.I WATER BRANCH PIPE
2
from water main
DEEP WELL 3
4" Ø G.I WATER MAIN SUPPLY
PIPE TO WATER TANK

P FIRST FLOOR WATER SUPPLY LAYOUT


SCALE 1:100
1 1
SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00
4.00 4.00 4.00
2.50 1.50

1.00
3
4"Ø G.I WATER RISER

2.00

1.00
R

3
SV

2.00
2.00
AV

AC
5.00

2.00

3.00

12.00
10.00

2.00
2

1.00
1
2" Ø G.I WATER BRANCH PIPE
2.00
5.00

4.00
2.00
1

P SECOND FLOOR WATER SUPPLY LAYOUT


2 2 SCALE 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00

4"Ø pvc MAIN STORM WATER DRAIN PIPE

4.00 4.00 4.00


2.50 1.00

RL CB S S S S S S S S S S S S S

1.00
6" Ø pvc STORM PIPE

S
2.00

S
CB RL

1.00
3

S
2.00

SS
5.00

5.00
S
2.00

12.00
S
10.00

2.00
2

RL CB

1.00
SS
2.00

2.50
S

CB RL
5.00

S
S
2.00

S
S

1.50
1

S
S

RL CB

S
S
S

6" Ø pvc STORM PIPE

4" Ø pvc STORM PIPE

TO PUBLIC TO PUBLIC
STORM DRAIN STORM DRAIN

P GROUND SURFACE, STORM DRAIN LAYOUT


3 3 SCALE 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00
4"Ø pvc SOIL BRANCH PIPE 4"Ø pvc SOIL STACK PIPE
WITH 2"Ø pvc BENT PIPE WITH 2"Ø pvc BENT PIPE

4.00 4.00 4.00


2.50 1.00

1.00
2.00

SEPTIC VAULT

1.00
3

2.00
5.00

5.00
2.00

12.00
wc
10.00

2.00
2

C.O

1.00
2.00

2.50
5.00

2.00

1.50
wc
1

C.O

4"Ø pvc SOIL BRANCH PIPE


WITH 2"Ø pvc BENT PIPE

P FIRST FLOOR SOIL PIPE, SEWER LAYOUT


SCALE
4 4 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00
4"Ø pvc SOIL STACK PIPE
WITH 2"Ø pvc BENT PIPE

4.00 4.00 4.00


2.50 1.50

1.00
2.00

1.00
MSWV
3

2.00
2.00
wc
C.O

5.00

2.00

3.00

12.00
10.00

2.00
2

1.00
2.00
5.00

4.00
2.00
1

P SECOND FLOOR PIPE, SEWER LAYOUT


5 5 SCALE 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00

4.00 4.00 4.00


2.50 1.50
RL

1.00
DS

2.00
RL

1.00
3

2.00
2.00

SURFACE
RUN-OFF
5.00

2.00

3.00

12.00
RL
10.00

2.00
2

DS

1.00
2.00
5.00

RL

4.00
SURFACE
RUN-OFF
2.00
1

RL

DS

P SECOND FL. STORM WATER DRAIN PN.


6 6 SCALE 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00

4.00 4.00 4.00


2.50 1.00

1.00
CEESPOOL
2.00
MSWV

1.00
3

2.00
Fdn

5.00

5.00
2.00
Sdn

12.00
lav
10.00

2.00
2

C.O

1.00
2.00

2.50
5.00

lav
2.00

1.50
Fdn
Sdn
1

C.O

P 1F WASTE WATER DRAIN SEWER LAYOUT


SCALE
7 7 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00

4"Ø pvc MAIN WASTE WATER PIPE


WITH 2"Ø pvc BENT PIPE

4.00 4.00 4.00


2.50 1.50

1.00
2.00

1.00
MSWV
3

2.00
Sdn

2.00
Fdn
lav.
C.O

5.00

2.00

3.00

12.00
10.00

2.00
2

1.00
2.00
5.00

2.00
1

P 2F WASTE WATER DRAIN, SEWER LAYOUT


8 8 SCALE 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


A B C D

12.00

4.00 4.00 4.00


2.50 1.50

DS

2.00

1.00
3

SURFACE
RUN-OFF
2.00
5.00

8.15

6.15
2.00

SURFACE
RUN-OFF
10.00

2.00
2

1.00
2.00

1.00 5.20
5.00

DS
6.20
2.00
1

P ROOF SURFACE DRAIN, STORM LAYOUT


9 9 SCALE 1:100

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


PLUMBING : SEWER : STORM : STORM :
GENERAL PLUMBING NOTES
Black waste water Roof Storm Ground Storm
ALL PLUMBING WORKS AND INSTALLATION MISCELLANEOUS Drain System Drain System
discharge system
SHALL COMPLY WITH THE PROVISIONS OF THE
LATEST EDITION OF THE NATIONAL PLUMBING SEPTIC TANK MSWV
CODE OF THE PHILIPPINES, AND THE RULES ks wc

SURFACE

STORM DRAIN
RUN-OFF
C.O DS

TO PUBLIC
AND REGULATION OF THE UTILITY COMPANIES a DS
CONCERNED. G G P P
ST
C.O to S S
ALL MATERIALS TO BE USED SHALL BE NEW wye - 1/8 bend - p trap connection ks RL CB
wc Septic Tank
APPROVED TYPE APPROPRIATE FOR BOTH to catch basin
4" Ø PVC SOIL STACK PIPE 3"Ø PVC STORM PIPE RL 4" Ø IPVC GROUND STORM PIPE
LOCATION AND INTENDED USE. 3"Ø PVC BRANCH & WASTE WATER STACK PIPE

* TYPICAL TO ALL FIXTURES EXCEPT WC ( min. recommended size ) ( min. recommended size ) ( min. recommended size )
Stack p. as seen
PLUMBING INSTALLATION SHALL BE UNDER MSWV MAIN SOIL AND
DIRECT SUPERVISION OF A DULY REGISTERED on top STACK PIPE C.O. WASTE VENT PIPE SURFACE RUNOFF SURFACE RUNOFF
MASTER PLUMBER. below STACK PIPE CLEAN OUT G GUTTER LINE DS DOWNSPOUT
Btdn BATH TUB DRAIN WC WATER CLOSET DS DOWNSPOUT RL ROOF LEADER
NO REVISION IN THE DESIGN SHALL BE DONE
WITHOUT THE PRIOR KNOWLEDGE OF THE Lt LAUNDRY DRAIN KS KITCHEN SINK RL ROOF LEADER CB CATCH BASIN
DESIGNER AND THE OWNER, ANY SUCH a 2" x 3" REDUCER P PERFORATED PIPE
REVISION DONE WITHOUT THE CONSENT
OF THE DESIGNER, HIS RESPONSIBILITY SHALL S STORM PIPE
CEASE AS A WHOLE. WATER : WATER : SEWER : PLUMBING

Hot water Household Main supply pipe Gray waste water


Others
supply pipe system system discharge system

INTERPRETATION OF DRAWINGS SV AV R GV CV Hb MSWV


Fdn lav
GV M C.O
Intersecting plumbing lines without "tick" marks denotes / AC GV a
suggests that there is no connection made between these pipe HWT
lines. SV AV GV
from water main
C.O to
Air Chamber denoted as AC at every end of a water line hws hws to household dist. Fdn lav Storm drain
implies only one of its location aside from every end of a fixture.
Hot water supply line Hot water O.T
Tank 3
4"
1
2"
Ø RISER SUPPLY PIPES
Ø BRANCH HOUSEHOLD SUPPLY PIPES
4" Ø PVC SOIL STACK PIPE
3"Ø PVC BRANCH & WASTE WATER STACK PIPE

The plumbing lines indicated in this layout suggest its * use 1/2" insulated pipe ( min. recommended size ) ( min. recommended size )
general location and direction, it must be followed on site. * To all Fixtures and pipe ends
M MSWV MAIN SOIL AND
However, if site condition does not permit, rerouting may be AIR CHAMBER WATER METER
AC M C.O. WASTE VENT PIPE BTDN BATH TUB DRAIN
made. the new layout must be drawn and made available in the
as-built plan for future trouble shooting. GV GATE VALVE GV GATE VALVE CLEAN OUT SL SLOP SINK

The plumbing lines indicated in this layout with hidden R RISER PIPE R RISER PIPE FDN FLOOR DRAIN LT LAUNDRY TUB
lines does not suggest actual location & direction, only SV SHOWER VALVE CV CHECK VALVE LAV LAVATORY SDN SHOWER DRAIN
connectivity.
AV ANGLE VALVE Hb HOSE BIBB a 2" x 3" REDUCER S STORM PIPE
Nipple Provision for tapping faucets
Couling or valves OT OVERHEAD TANK
PLUMBING NOTES P PLUMBING LEGENDS / SYMBOLS
SCALE
1010 NOT TO SCALE

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


CONCRETE COVER 3
'' STEEL FRAME
L1 + L2 + 450
4

FLOOR LINE

150 L1 (INSIDE LENGTH OF DIGESTIVE CHAMBER) 150 L2 (CESPOOL CHAMBER) 150

150

SECTION SHOWING RSB


SLAB

ANCHOR BOLT

SECT. A-A'
U - BOLT

CLEANOUT COVER
THREADED BOLT WITH NUT
AND LOCKWASHER

160 240
WALL

W + 300
PIPE HANGER DETAIL-1

SECTION SHOWING TOP & MANHOLE


PIPE HANGER DETAIL-2

BEND
REDUCER

BRANCH PIPE

CLEANOUT DETAIL

P PIPE HANGER P CLEAN OUT

150
11A SCALE AS SHOWN
11B SCALE AS SHOWN

PIPE HANGER

CAP
CAULK SEAL SECTION SHOWING MASONRY WALL 2 CHAMBER CESPOOL
CAULKING
10mm Ø HANDLE

100
AIR CHAMBER

PLAN
VENT PIPE

REDUCER
FLOOR LINE

300
AIR SPACE
SURFACE LEVEL OF DIGESTION CHAMBER
SURFACE LEVEL OF
CEESPOOL

D + 507
100mm X 100mmØ SANITARY TEE SOIL PIPE INLET
TO FIXTURES 100mm Ø SOIL PIPE OUTLET

12mm REBAR SPACED @ 300mm, O.C, BOTHWAYS

TEE

D
TEE

6% SLOPED TOWARDS THE CENTER


10mm Ø HORIZONTAL BAR PLACED EVERY
FDN / SDN 3 LAYERS OF CHB

AC FLOOR DRAIN 150 mm THICK CHB WALL


WITH 10mm Ø REBARS SPACED @ 0.80m, O.C

AIR CHAMBER

P AIR CHAMBER P FLOOR DRAIN


107

SECTION A-A' 200mm X 400mm FOOTING


WITH 3D10mm Ø TIES @ 300m, O.C

11C SCALE
11D AS SHOWN SCALE AS SHOWN

P PLUMBING DETAILS P SEPTIC VAULT P PLUMBING DETAILS


1111 1211 SCALE AS SHOWN
1311 SCALE AS SHOWN

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


2'' Ø VENT PIPE

2'' X 3'' TEE

3''Ø TEE W/ 2''X3'' REDUCER

3'' Ø WYE
3'' Ø WYE
3'' Ø 81 BEND
3'' Ø ELBOW

WASTE WATER &


SOIL STACK PIPE
PIPE CLAMP

3
4 " Ø B.I. PIPE HANDLE

PIPE SLEEVE

3
16 '' X 1'' ANGLE BAR PIPE HANGER
200

4'' THICK R.C. SLAB

WC BLACK WASTE WATER FITTINGS


LAV GRAY WASTE WATER FITTING
50
32.5 100

P FIXT. FITTINGS P FIXT. FITTINGS


10mm REBARS
16 A SCALE NTS
16B SCALE NTS
400

3'' Ø ROOF LEADER


COMMON 2'' Ø PVC VENT PIPE

4'' Ø PVC STORM PIPE 3''Ø ELBOW 2'' X 3'' TEE


1
2 '' Ø BUSHING
PVC VENT STACK PIPE

3''Ø P-TRAP
3'' Ø WYE

1
2'' Ø ELBOW
100

1
2'' Ø TEE
SWAY BRACE

E
PIP
ER
400 AT
TEW
WAS 1
AY 2'' Ø COLD WATER SUPPLY PIPE
GR
H
A NC
BR
C
PV
Ø
3''

FDN GRAY WASTE WATER FITTINGS WC WATER SUPPLY FITTINGS

P FIXT. FITTINGS P FIXT. FITTINGS


16 C SCALE NTS
16D SCALE NTS
200
550

LAV WATER SUPPLY FITTINGS 1


2''Ø END CAP
SHOWER WATER SUPPLY FITTINGS
1
2''Ø BUSHING
4'' Ø PVC STORM PIPE
TO SEPTIC VAULT
1
2'' Ø BUSHING

1
2'' Ø ELBOW
4'' CHB

1
2 '' Ø TEE
1
2 '' Ø TEE 1/2 '' Ø TEE
SOIL PIPE & STORM LAYOUT
1
2'' Ø COLD WATER SUPPLY PIPE 1
2'' ELBOW 1
2'' ELBOW

P CATCH BASIN P MSWV PIPE S. VALVE

1
2'' Ø TEE

1412 1512
SCALE AS SHOWN SCALE NTS

P PLUMBING DETAILS P FIXT. FITTINGS P FIXT. FITTINGS


1612 SCALE AS SHOWN
16E SCALE NTS
16F SCALE NTS

SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3


CURTAIN ROD FACIAL MIRROR

TOWEL BAR TOWEL BAR

LAVATORY

TISSUE PAPER HOLDER

SUPPLY PIPE

WATER CLOSET BATHTUB

WATER CLOSET & B.TUB LAVATORY, TOWEL &MIRROR

SHOWER HEAD

CURTAIN ROD

MIXING VALVE

SOAP HOLDER

FOOT FAUCET

SHOWER

P MOUNTING HEIGHTS
SCALE AS SHOWN
1713
SUBJECT STUDENT PLATE TITLE

AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED

AR. ERWIN P. GERARDO BS ARCHITECTURE 3