A
Figure 2 - Assembly Cross Section
Tightening Sequence A,B,C,D,etc. If a bolt head does not shear, the installer should verify that the
appropriate torque was met (see Table 1). If a minimum cover
CENTER must be maintained, the bolt head can be cut off after the proper
STOP PIN torque has been applied.
Figure 3 - Detail A
Solid contact between bar and stop pin as shown.
WARNING:
1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at www.nVent.com and from your
nVent customer service representative.
2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.
4. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily
injury and/or death, and void your warranty.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are registered trademarks
of nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reservers the right to change
specifications without prior notice.
TECHNICAL SUPPORT:
www.nVent.com IP8515_B 1 of 2 © 2017-2018 nVent All Rights
Reserved
INSTRUCTION SHEET
A
Table 2 - Maximum Shear Lip
Equipment Specifications
To reach the specified torques in Table 1, a 1" square drive pneumatic impact wrench and air compressor are required
for coupler sizes 25 and larger. The air compressor should have a minimum of 185CFM at an operating air presure of
100 psi. This required air flow is to be delivered to the driver through a 3/4" to 1" air hose. An impact wrench must
have a minimum torque capacity of 250 ft-lb for coupler sizes 16-22, 500 ft-lbs for coupler size 25, and 1000 ft-lbs for
coupler sizes 28 and greater. Other tools such as electric impact wrenches, nut-runners or hand wrenches may be used
as long as the appropriate torque is attained and validated.