Professional Documents
Culture Documents
XAORI-LCM Series Safety Light Curtain
XAORI-LCM Series Safety Light Curtain
LCM series
safety light curtain LCM series miniature safety grating is a new type of anti-
radiation product developed with foreign advanced technology.
Taking into account the economy and safety, the product has
passed the European CE certification (EN1496-1/2) safety level
four. It has strong stability and can completely replace the
corresponding imported products, such as: GL-S series, SAS
series, PJV series, C4C series, etc. It has been widely used in
assembly lines, injection molding machines, hydraulic presses,
and other automated special equipment. This grating has the
following characteristics:
安全知识
普及
11
15
6.6
4
15
24
14
LCM:Miniature grating
15
Technical parameter
安全光栅
安全光栅
LCM series miniature safety light grid (10/20/25/40 series)
Protection height 180~3240mm (can be customized according to customer requirements) Response time ≤20ms
Number of optical 4~200 (standard light points), more points can be customized Outer enclosure
protection level IP65 (IP67 is required for waterproof series, please choose outlet)
axes
Optical axis spacing
(resolution) 10mm (15mm) / 20mm (25mm) / 25mm (30mm) / 40mm (45mm) Operating temperature
-10~55°C
Infrared wavelength 940nm -20~70°C
Storage temperature
发射器
接收器
发射器
接收器
安全光栅
Common Troubleshooting of LCM Series Safety Light curtain
安全开关 receiver
LED indicator illustrate
安全门锁 №1 green light All light speed conduction
OSSD1黑
OSSD2白
OSSD1黑
OSSD2白
№2 red light There is a speed of light interruption (not on the right light)
屏蔽地
屏蔽地
屏蔽地
屏蔽地
安全模块 №3 1Hz green light flashing There is interference
开关 №5 1HZ red light flashes Output error overload short circuit, etc.
电源
电源
2Hz red and green flash Select circuit failure
№7 alternately
№8 1Hz red and green flash Primary and secondary MCU communication error
alternately
receiver
LED indicator illustrate
warn
!
● Please connect the dual output to the control safety system of the device. If the output is single, the safety level will not be met.
● Make sure that the wiring is performed with the power off.
● Make sure that the change of the power supply voltage does not exceed the rated range.
● Do not run wires together with high-voltage or power lines or in the same line, which may
Malfunction due to induction.
● Do not use it within a short time (2S) after the power is turned on.
● Avoid dust, dirt and water vapor.
● Do not put the grating in direct contact with water, oil, grease or organic solution (such as thinner).
● Do not expose the grating directly to the fluorescence of fast-start lamps or high-frequency lighting, which can affect
sound detection performance.● If possible, the grating should be installed with insulation as far as possible.
LCM series miniature safety light grid signal interface definition and application wiring diagram.
安全光栅
安全光栅
name color illustrate
launcher Brown+24VDC Supply voltage, DC 24V
blue GND Power 0V
Brown+24VDC Supply voltage, DC 24V
blue GND Power 0V
receiver Safety output 1: NPN type output or PNP type output (can directly enter PLC, safety relay)
Black OSSD1
White OSSD2 Safety output 2: NPN type output or PNP type output (can directly enter PLC, safety relay)
安全知识
普及
launcher
receiver
launcher
receiver
安全光栅
安全开关
NPN type wiring diagram PNP type wiring diagram
安全门锁
OSSD
OSSD
OSSD
OSSD
hield ground
shield ground
ground
shield
shield ground
b 安全模块
l white br b b white
brown blue br blue r
a blue o l
o
c l l w o a
blue w lo load 2
k o o n w c
n ad
a a n k 1
d d 门开关
2
1
power power
24V supply 24V supply
0V 0V
LCM safety light grid (NPN) and SCDA127R/N application wiring diagram LCM safety light grid (PNP) and SCDA127R application wiring diagram
White White
black black
Peripheral Driver 2 Peripheral Driver 2
SCDA127R/N SCDA127R
0V 0V
LCM series miniature safety light grid
20 series (optical axis spacing: 20mm, resolution: 25mm) and installation dimensions
Protection height
Number Dimensions L*W*H
of
shape Model (PNP) Model (NPN) optical (mm)
axes (mm)
5 .2
LCM0984-PD20□□ LCM0984-ND20□□ 48 980 25*28*984
6.6
5 .2
6.6
安全光栅
6
LCM1064-PD20□□ LCM1064-ND20□□ 52 1060 25*28*1064
S=N*25+26
LCM1464-PD20□□ LCM1464-ND20□□ 72 1460 25*28*1464
16
10
16
5.2 LCM1864-PD20□□ LCM1864-ND20□□ 92 1860 25*28*1864
5.2
5.2
4.4
15.8
LCM1944-PD20□□ LCM1944-ND20□□ 96 1940 25*28*1944
4.4
Front view
LCM2024-PD20□□ LCM2024-ND20□□ 100 2020 25*28*2024
15.8
2.9
25.3
10
12.6
15.8
28.4
LCM2504-PD20□□ LCM2504-ND20□□ 124 2500 25*28*2504
Note: ◎ Protective height: the effective height that can detect the test rod (diameter is the length of the spacing) = (n+1) × optical axis spacing
◎ n: number of light spots
◎ □□ The optional number is the distance, and the customer fills in according to the needs, such as 10: 1M, 30: 3M
◎The above are some specifications and models
◎ The cables need to be purchased separately. The standard length of shipment is 3M, and other lengths are 4.5M, 6M, and 10M. Remarks are required.
25 series (optical axis spacing: 25mm, resolution: 30mm) and installation dimensions
Number
of Protection Dimensions L*W*H
Model (PNP) Model (NPN)
shape optical height
axes mm
mm
5 .2
6.6
5 .2
安全光栅
6
12.6
21.5
LCM0726-PD25□□ LCM0726-ND25□□ 28 725 25*28*726
6
10
16 LCM0776-PD25□□ LCM0776-ND25□□ 30 775 25*28*776
安全开关
LCM0826-PD25□□ LCM0826-ND25□□ 32 825 25*28*826
S=N*25+26
LCM0976-PD25□□ LCM0976-ND25□□ 38 975 25*28*976
15
门开关
10
16
LCM1176-PD25□□ LCM1176-ND25□□ 46 1175 25*28*1176
5.2
5.2 LCM1226-PD25□□ LCM1226-ND25□□ 48
4.4
4.4
15.8
LCM1276-PD25□□ LCM1276-ND25□□ 50 1275 25*28*1276
Front view
LCM1326-PD25□□ LCM1326-ND25□□ 52 1325 25*28*1326
15.8
2.9 LCM1476-PD25□□ LCM1476-ND25□□ 58 1475 25*28*1476
25.3
LCM1526-PD25□□ LCM1526-ND25□□
25.3
10 60 1525 25*28*1526
12.6
LCM1576-PD25□□ LCM1576-ND25□□
12.6
15.8
62 1575 25*28*1576
Note: ◎ Protective height: the effective height that can detect the test rod (diameter is the length of the spacing) = (n+1) × optical axis spacing
◎ n: number of light spots
◎ □□ The optional number is the distance, and the customer fills in according to the needs, such as 10: 1M, 30: 3M
◎The above are some specifications and models
◎ The cables need to be purchased separately. The standard length of shipment is 3M, and other lengths are 4.5M, 6M, and 10M. Remarks are required.
LCM series miniature safety light grid
LCM series safety light grid (NPN) and relay application wiring diagram LCM series safety light grid (PNP) and relay application wiring diagram
black
relay
relay
black peripheral
peripheral driver
driver
white
peripheral driver
安全知识
普及
blue blue blue blue
5 .2
6.6
安全光栅
21.5
10
3.5
安全开关 LCM series safety light grid (NPN) and PLC application wiring diagram LCM series safety light grid (PNP) and PLC application wiring diagram
S=N*10+26
brown brown brown brown
安全门锁
launcher Receiver NPN launcher Receiver PNP PLC and SCM system
PLC and SCM system
10
12.5
white
安全模块
10
peripheral
16
black driver 1
4.4
开关
black
peripheral
white
driver2
peripheral driver
15.8
25.3
blue blue
12.6
blue blue
LCM series miniature safety grating connected to PLC (Mitsubishi) programming reference program
SET M0
OSSD1 OSSD2 Y1 Y2 grating working status
0SSD1 0SSD2 input input output output
0 0 Fault
0 1
M8002
Fault
RST M0 1 0 0 0
Note: 0SSD1/2 input refers to the output of the grating to the PLC signal;
Y1
Y1/Y2 refers to the output signal after the PLC has processed OSSD1/2;
"0" means off, "1" means on.
10 series (optical axis spacing: 10mm, resolution: 15mm) and installation dimensions
Protection heigh
Number Dimensions L*W*H
Model (PNP) Model (NPN) of
mm
shape optical mm
axes
5 .2
LCM0676-PD10□□ LCM0676-ND10□□ 65 660 25*28*676
6.6
安全光栅
6
LCM0726-PD10□□ LCM0726-ND10□□ 70 710 25*28*726
21.5
12.6
75 760
10
LCM0776-PD10□□ LCM0776-ND10□□ 25*28*776
3.5
安全开关
LCM0826-PD10□□ LCM0826-ND10□□ 80 810 25*28*826
S=N*10+26
10 LCM0876-PD10□□ LCM0876-ND10□□ 85 860 25*28*876
安全门锁
LCM0926-PD10□□ LCM0926-ND10□□ 90 910 25*28*926
10
12.5
LCM0976-PD10□□ LCM0976-ND10□□ 95 960 25*28*976
10
16
LCM1076-PD10□□ LCM1076-ND10□□ 105 1060 25*28*1076
5.2
5.2
LCM1126-PD10□□ LCM1126-ND10□□ 110 1110 25*28*1126 门开关
4.4
15.8
15. 8
2.9
LCM1326-PD10□□ LCM1326-ND10□□ 130 1310 25*28*1326
25.3
10 LCM1376-PD10□□ LCM1376-ND10□□ 135 1360 25*28*1376
12.6
LCM1426-PD10□□ LCM1426-ND10□□ 140 1410 25*28*1426
15.8
LCM1476-PD10□□ LCM1476-ND10□□ 145 1460 25*28*1476
28.4
Note: Protective height: the effective height that can detect the test rod (diameter is the length of the spacing) = (n+1) × optical axis spacing
n: number of light spots
The optional number is the distance, and the customer fills in according to the needs, such as 05: 0.5 meters, 10: 1 meters, 20: 2 meters
The cables need to be purchased separately. The standard length of shipment is 3M, and other lengths are 4.5M, 6M, and 10M. Remarks are required.
The above are some specifications and models
LCMseries miniature safety light grid
40 series (optical axis spacing: 40mm, resolution: 45mm) and installation dimensions
Protection heigh Dimensions L*W*H
Number
shape Model (PNP) Model (NPN) of
mm
optical mm
axes
6.6
21.5
10
LCM1304-PD40□□ LCM1304-ND40□□ 32 1320 25*28*1304
安全开关 32
LCM1384-PD40□□ LCM1384-ND40□□ 34 1400 25*28*1384
开关
16
15.8
LCM2104-PD40□□ LCM2104-ND40□□ 52 2120 25*28*2104
2.9
LCM2504-PD40□□ LCM2504-ND40□□ 62 2520 25*28*2504
25.3
10
LCM2584-PD40□□ LCM2584-ND40□□ 64 2600 25*28*2584
12.6
15.8
LCM2664-PD40□□ LCM2664-ND40□□ 66 2680 25*28*2664
28.4
LCM2744-PD40□□ LCM2744-ND40□□ 68 2760 25*28*2744
top view
LCM2824-PD40□□ LCM2824-ND40□□ 70 2840 25*28*2824
Note: ◎ Protective height: the effective height that can detect the test rod (diameter is the length of the spacing) = (n+1) × optical axis spacing
◎ □□ The optional number is the distance, and the customer fills in according to the needs, such as 10: 1M, 30: 3M
◎ The cables need to be purchased separately. The standard length of shipment is 3M, and other lengths are 4.5M, 6M, and 10M. Remarks are required.
◎ n: number of light spots
◎The above are some specifications and models