A124-9550-00E_0918.

fm 1 ページ 2008年10月8日 水曜日 午後9時55分

DF-620 Reverse Automatic Document Feeder


INSTALLATION MANUAL
Applied Machine: 362/282/222
MFP: 36 ppm/28 ppm/22 ppm
Product Code: A11U/A11V/A11W

I. Accessory parts II. Installation procedures


No. Name Figure Q’ty 1. Remove the protective tape and shipping preser-
vatives and remove the protective plastic bag of
1. Reverse the hookup cord.
Automatic Doc-
ument Feeder 1

A124IXC044MA

2. Shoulder
Screw 2
A124IXC001MA

3. Decorative
Screw 2
A124IXC002MA

4. Document Pad

1 A124IXC005MA

A124IXC003MA

5. Test chart

A124IXC004MA

6. Installation
Manual
1
set
A124IXC006MA

4980IXC019DA
2. Turn off the machine and unplug the power cord
from the machine.
3. Install the two shoulder screws furnished with the
reverse automatic document feeder to the hinge
mounting portion.
After unpacking, be sure to get rid of the
packaging materials and keep them out of Note:
the reach of children. Use the outer threaded holes to install the shoul-
der screws.
Putting your head in the wrapper involves
danger of suffocation.

A124IXC007MA

E-1 A124-9550-00
A124-9550-00E_0918.fm 2 ページ 2008年10月8日 水曜日 午後9時55分

4. Place the reverse automatic document feeder on 7. Fit the hookup harness into the hook on the
the machine, and fix it with two decorative screws machine.
provided.

A124IXC008MA
A124IXC012MA

III. Adjusting the Height


1. Place the document pad, with its side to which
sponges are affixed facing up, onto the original
glass.
2. Loosen the nut on the upper side of the left hinge
as viewed from the control panel side (by turning
it in the direction of B).
A124IXC009MA

5. Remove the cover of the reverse automatic docu- Nut


ment feeder connector.

A124IXC013MA

A124IXC010MA

6. Connect the hookup harness connector of the


reverse automatic document feeder to the mating
connector on the machine side.

A124IXC014MA

A124IXC011MA

E-2
A124-9550-00E_0918.fm 3 ページ 2008年10月8日 水曜日 午後9時55分

3. Prepare a strip of paper using copy paper, place it * As guidelines for the force to pull out the strip of
at the location shown in the illustration, and gen- paper, it is equivalent to that exerted when lifting
tly lower the reverse automatic document feeder. the inner guide plate with a finger.
* Prepare the strip of paper as follows:
Size: 20 mm × 210 mm
Paper weight: 60 to 80 g/m2

A124IXC019MA

5. After the reverse automatic document feeder has


been adjusted for height, tighten the nut which
has been loosened in step 2.
A124IXC015MA
6. Check the clearance between the document
scanning glass surface and the protrusion on the
reverse automatic document feeder side.
210 mm * There must be no clearance between the protru-
sion on the reverse automatic document feeder
and the document scanning glass surface.
* If there is any clearance, loosen the nut on the
right hinge as viewed from the control panel side
20 mm
A124IXC016MA and turn the height adjusting screw as necessary
to adjust the height.
4. Turn the screw on the left hinge as necessary so * If there is any clearance, turn the screw clock-
that you feel resistance when pulling out the strip wise.
of paper.
* If you feel a strong resistance, turn the screw
clockwise.
If you feel a feeble resistance, turn the screw
counterclockwise.

A124IXC017MA

Height adjusting screw

A124IXC020MA

7. After the adjustment has been made, positively


tighten the nut on the right hinge.
A124IXC018MA

E-3
A124-9550-00E_0918.fm 4 ページ 2008年10月8日 水曜日 午後9時55分

IV. Checking for Skew Feed V. Adjusting Skew Feed


1. Set that A3 or 11 × 17 is loaded in the 1st 1. Loosen the decorative screw on the right hinge
paper drawer. viewed from the front.
2. Plug the power cord into the power outlet and 2. Loosen the nut on the back of the hinge and
turn ON the machine. adjust the position of the reverse automatic docu-
ment feeder as detailed below.

20 mm

Decorative
screw Nut

A124IXC021MA

A124IXC024MA
3. Load the test chart in the reverse automatic docu-
ment feeder and make one 1-sided copy five con- 3. If there is a deviation as shown on the illustration,
secutive times. turn the screw counterclockwise to adjust it.

4688U001AB

A124IXC022MA

4. Fold each of the sample copies as illustrated and A124IXC025MA

check for any deviation.


4. If there is a deviation as shown on the illustration,
Specifications: 0 ± 3.0 mm
turn the screw clockwise to adjust it.
* If the deviation does not fall within the specified
range, perform the following adjustment proce-
dure.

4688U002AB

A124IXC026MA

A124IXC023MA
5. After the adjustment procedure has been com-
pleted, tighten with a screwdriver the decorative
screw which has been loosened in step 1.
6. Tighten the nut which has been loosened in step
2.

E-4
A124-9550-00E_0918.fm 5 ページ 2008年10月8日 水曜日 午後9時55分

VI. Affixing the Document Pad VII. Checking the Reference Zoom Ratio
1. Raise the reverse automatic document feeder. 1. Load the test chart in the reverse automatic docu-
2. Remove the document pad from the reverse ment feeder and make a full-size copy.
automatic document feeder.
Note:
When removing the document pad, pull apart the
hook and loop fastener one by one. Pulling them
all at once may damage the sponge.
3. With the rear edge of the document pad pressed
up against the original length scale, place it on
the original glass so that its left edge is 0.5 to 1.0
mm away from the original width scale.

A124IXC022MA

2. Check that the lengths of the reference lines


0 mm
reproduced on the copy, A (CD) and B (FD), meet
the following specifications.
0.5 to 1.0 mm Reference line registration specifications:
A (CD): 250 ± 2.5 mm (± 1.0 %)
B (FD): 400 ± 6.0 mm (± 1.5 %)

A124IXC027MA

4. Gently lower the reverse automatic document


feeder.
250 mm (A)

Note:
When lowering the reverse automatic document
feeder, use utmost care to prevent the document
pad from deviating from its correct position.
5. Gently raise the reverse automatic document
feeder and press the document pad up against
the reverse automatic document feeder by hand 400 mm (B)
so that it is affixed in position. A124IXC028MA

* If the length of the line reproduced on the copy


falls outside the specified range, make the
“Adjusting the Reference Zoom Ratio.”
* If the length of the line reproduced on the copy
falls within the specified range, go to “Checking
for Registration.”

E-5
A124-9550-00E_0918.fm 6 ページ 2008年10月8日 水曜日 午後9時55分

VIII. Adjusting the Reference Zoom Ratio IX. Checking for Registration
Step Step
1. Call the Tech. Rep. Mode to the screen. 1. Load the test chart in the reverse automatic
(For details of how to call the Tech. Rep. document feeder and make a full-size copy.
Mode screen, see the Service Manual.)
2. Touch “Tech. Rep. Choice.”
3. Touch “Sheet-through-ADF.”
4. Touch “Zoom.”
5. Touch the “Copy” of “CD” or “FD.”
6. Make the zoom adjustment.
A (CD) / B (FD)
* If the line is longer than the specifications,
adjust toward the reduction side.
* If the line is shorter than the specifications, A124IXC022MA

adjust toward the enlargement side.


2. Make a full-size copy using the 2-side origi-
Adjustment procedure nal/2-side copy mode. (Face down the test
1. Press the Clear key. shart.)
2. Enter the value from the 10-Key pad.
Adjustment Range: ×1.010 to ×0.990 (CD)
×1.020 to ×0.980 (FD)
3. Load the test chart in the reverse automatic
document feeder and touch “Test Print.”
4. Check for correct zoom again.
5. Touch “END.”
6. Press the Reset key and touch “Exit.”

A124IXC035MA

3. Check that the margins reproduced on the


copy meet the following specifications.
* In full size copy mode
Margin registration specifications:
Width A: 20 ± 3.0 mm
A124IXC033MA A124IXC034MA
Width B: 20 ± 2.0 mm
* In 2-side original mode
Margin registration specifications:
Width A: 20 ± 3.5 mm
20 mm (A)

20 mm (B)

A124IXC036MA

* If the margins reproduced on the copy fall


outside the specified range, make the
“Adjusting Registration.”

E-6
A124-9550-00E_0918.fm 7 ページ 2008年10月8日 水曜日 午後9時55分

X. Adjusting Registration XI. Changing the Stopper Position


1. Remove the stopper from the hinge of the
Step reverse automatic document feeder.
1. Call the Tech. Rep. Mode to the screen. 2. Change the set position of the stopper to the
(For details of how to call the Tech. Rep. upper side and secure it in position.
Mode screen, see the Service Manual.)
2. Touch “Tech. Rep. Choice.”
3. Touch “Sheet-through-ADF.”
4. Touch “Feed (CD)” or “Feed (FD).”
* Feed (CD)
Enter the value obtained by dividing the
correction amount by 0.04.
* Feed (FD)
Adjustment range:
Max: +4.0 mm (F), +4.0 mm (B)
Min.: -4.0 mm (F), -4.0 mm (B)
A124IXC043MA
5. Study the illustration below and adjust regis-
tration.
Registration (FD)

- direction + direction
Registration (CD)

- direction
B

+ direction

A
A124IXC042MA

Adjustment procedure
1. Press the Clear key.
2. Press the key to change the sign to
select either + or -.
3. Enter the numeric value from the 10-Key
pad.
4. Load the test chart in the reverse automatic
document feeder and touch “Test Print.”
5. Check for correct registration again.
6. Touch “END.”
7. Press the Reset key and touch “Exit.”