Ml IRCONINTERNATIONALLTD 52-7 (A Govt. of India Undertaking) ‘An Integrated Engineering & Construction Company No, IRCON/ELECT/5021/USBRL/TSS/4 J /9 2 Date: 12/11/2020 M/s KEI Industries Ltd, D-0, Okhla Industrial Area, Phase-I, New Delhi - 110020. pproval of GTP/Design/Drawings/Test Plan etc. for 132 kV Double Pole CB (Make ABB) in connection with “Design, Supply, Installation, Testing & Commissioning of 132/25 kV, 21.6/30.24 MVA, ONAN/ONAF (Double Transformer) Traction Sub-Station complete in all respect in Banihal-Qazigund-Baramulla Section of USBRL Project of Northern Railway”. Ref: a) HQ/NR's letter no. 230/Elect/TRD/26 Dated 03/06/20 b) M/s KEI’s proposal submitted vide letter No. _KEI-EPC/IRCON/TSS/2019- 20/8QB/DESIGN/019 on 05/06/20 and subsequent revised GA drawing submitted on 10/07/20, ©) RDSO’s approval received vide file no. RDSO-TIOLKO(PSI)/25/2020-O/o PED/TI/RDSO dated 11/11/20. Reference above, In Principle Approval towards the proposal for 132 kV Double Pole CB (Make: ABB; Type: LTB145D1/B with FSA1 mechanism) submitted vide letter under ref. (b) above, is hereby accorded subject to compliance of followings for further necessary action at your end: i) Since the required Dielectric test for high altitude has not been witnessed by RDSO, RDSO has advised to submit either third party test report of the Dielectric test from Government approved laboratory or conduct the Dielectric test for proposed ‘guaranteed dielectric values at ABB's works in the presence of Purchaser (IRCON/NR) representative, It is advised to submit Type Test Plan so that Purchaser representative may be nominated accordingly. ii) In addition, M/s ABB may also submit a declaration that the design of the CB tested for High Altitude is same which has been Type Tested by RDSO for the altitude 1000 Mtr as per RDSO specification no. TI/SPC/PSI/HVCB/0120(06/14) Rev.0 with A&C slip no. 01 & 02. ili) Since, there is no change in the design of the equipment which has been approved by RDSO, hence, with the successful type test report of the Dielectric Tests, the equipment can be used at present site condition. However, Insulation Level in Name Plate of the CB may be amended as proposed. Approved GA drawing with revised clearances in line with the NR’s approval under ref. (a) above Is attached. The approval does not absolve the contractor of his contractual obligations regarding correctness of design as per contract agreement. This issues with the approval of CGM (Elect)/CO. Thanking You, For & On behalf of Treon International Ltd 4 any (Abu monsur Ali) JGM (Elect) ‘USBRL-Jammu (Electrical): Subordinate Complex, Northern Railway Project Office, Behind Railway Yard Jammu - 180 012, INDIA, Tel: 0191-2473051, email: ircon.5021@ircon.org, Registered Office: C-4, District Centre, Saket, New Delhi-110017, INDIA Tel: +91-11-29565666, Fax: +91-11-26854000, 26522000 e-mail: info@ircon.org, Web : CIN ~145203DL1976GO1008171 2 | 3 4 EE | MASS IN KG a 1. CABLE INLET, REAKER POLES” | STRUCTURE, POLE BEAM ETC, | OPERATING MECHANISM [SF5 GAS” [TOTAL WASS I 300K2 E 550 arse G6 [7325 APPROX. | 2 TERMINAL OF ALUNINIDML 3. TERWINAL LOAD MAX4500 N STATIC / 3000 N DYNAMIC IN an OIRECTION. 4, HOLES FOR EARTHING|CLAMP. | L A 474 3500) COMPUTERORIGINAL DYNAMIC FORCE DURING OPE2ATION. —| ge 6 POLE BEAM. 7. ARC CHAMBER INSU! a 8, ‘OR. SUPPORT INSULATO! OPEN/CLOSE INDICAT 10. DENSITY MONITOR. 11. OPERATING MECHANIS| L 12 PLATFORM WITH LADDER | 13, FOUNDATION BOLT FOR STRUCTURE. | 14, FOUNDATION DETAIL FOR STRUCTURE. c CHARGING POINT |___1324_| ges = | Det4(15x) | 2 -SS-3 1464 3083 3385 2096, Detail-10 (Density mont : THTek 7 5 WRAVEL- | 2 t+ 1000N a“ 1O00N (HORIZONTAL) = 1 TS 12000N (VERTICAL) Foundation bolt artes D=32 for bolt M24 UU 420s 2520 Foundation plan [GENERAL ARRANGEMENT FOR (HB) ~Semr I ———~oesresae | 145 kV SFG CIRCUIT BREAKER nl ee TYPE LTB14501/B WITH FSAI ABB India ENGINEER |2\_ n\ve o PROOF CHECKER TSS DESIGN Depth |For foundation bolt “Sa” 59.750 ee ABB THYB907792-0001"" ae ee ; 4 3 a

You might also like