HEADING

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

COVERED AREA STATEMENT

SL COVERED AREA COVERED AREA COVERED AREA TOTAL COVERED


BLOCK HEIGHT
MODIFIED G+12 STORIED RESIDENTIAL BUILDING PLAN OF NO OF GROUND FLOOR 1ST TO 8TH FLOOR 9TH TO 12TH FLOOR AREA

REALTECH NIRMAN PVT. LTD. SITUATED AT 1 1 442.78 SQ. MTR 3551.92 SQ. MTR 1134.56 SQ. MTR
5129.26
SQ. MTR
39.95 MTR

MOUZA:MAHAMMADPUR, JL NO: 32, R.S / L.R DAG NOS: 1581, SL COVERED AREA COVERED AREA TOTAL COVERED AREA
(1ST TO 8TH
FLOOR-27.75
BLOCK MTR.)
NO
1582, 1583, 1584, 1586, 1587,1492 & 1493 UNDER L.R KHATIAN OF GROUND FLOOR 1ST TO 12TH FLOOR

2 2 353.82 SQ. MTR 4182.48 SQ. MTR 4536.30 SQ. MTR 39.95 MTR
NOS: 7/1, 297/1, 1258/1, 1283/1, 1312/1, 1330/1, 8134, 8135,8136,
3 3 445.02 SQ. MTR 5125.08 SQ. MTR 5570.10 SQ. MTR 39.95 MTR
8137, 8138, 8139, 8184, 8185, 8186, DISTRICT:
4 4 445.02 SQ. MTR 5125.08 SQ. MTR 5570.10 SQ. MTR 39.95 MTR
NORTH 24 PARGANAS , P.S: RAJARHAT UNDER RAJARHAT
5 5 445.02 SQ. MTR 5125.08 SQ. MTR 5570.10 SQ. MTR 39.95 MTR
BISHNUPUR 2 NO GRAM PANCHAYET.
6 6 406.65 SQ. MTR 4874.52 SQ. MTR 5281.17 SQ. MTR 39.95 MTR

7 CLUB-1 181.44 SQ. MTR 181.44 SQ. MTR 3.35 MTR

8 CLUB-2 181.44 SQ. MTR 181.44 SQ. MTR 3.35 MTR

NAME OF DEVELOPER:
REALTECH NIRMAN PVT. LTD.
AREA STATEMENT: (T-68, TEGHORIA MAIN ROAD, KOL-59)

1) AREA OF LAND: 180K-3CH-43 SFT (12056.67 SQM)


2) PERMISSIBLE F.A.R.: 2.25
3) PROPOSED F.A.R.: 2.241
4) PERMISSIBLE GROUND COVERAGE: 45%
5) PERMISSIBLE GROUND COVERAGE AS PER RULES: 5425.50 SQM SK. NASIR (DIRECTOR)
6) PROPOSED GROUND COVERAGE: SIGNATURE OF DEVELOPER
6/1) BLOCK:1= 442.78 SQM, (6/2) BLOCK:2= 353.82 SQM, (6/3) BLOCK:3,4 & 5=
CERTIFICATE OF ARCHITECT:
(445.02 X 3) = 1335.06 SQM, BLOCK:6= 406.65 SQM,
I CERTIFY THAT ALL THE ARCHITECTURAL DRAWINGS OF THE PROJECTAT DAG NOS: 1581,
(6/4): GYM,SAUNA,COMMUNITY HALL , GAMES ROOM & CAFETERIA= 362.89 SQM 1582,1583,1584,1586,1587,1492 & 1493, KHATIAN NOS: 7/1, 297/1, 1258/1, 1283/1, 1312/1, 1330/1
7) TOTAL GROUND COVERAGE: 2901.20 SQM (24.06%) , 8134, 8135,8137, 8138, 8139, 8184, 8185, 8186, OF MOUZA: MAHAMMADPUR, JL NO: 32,
HAVE BEEN PREPARED BY ME COMPLYING WITH THE NEW TOWN KOLKATA PLANNING AREA
8) LEFT OPEN SPACE: 9155.47 SQM (BUILDING) RULES, 2014. I ALSO CERTIFY THAT THE PLANS AND DRAWINGS PREPARED BY
9) COVERED AREA OF 1ST TO 12TH FLOOR: 29118.72 SQM ME COMPLYING WITH ALL THE PROVISIONS REGARDING THE FIRE PROTECTION AS PER THE
PREVAILING NATIONAL BUILDING CODE OF INDIA. I SHALL BE HELD RESPONSIBLE IF ANY
BLOCK-1= {(443.99X8)+(283.64x4)= 4686.48}+ INCORRECT INFORMATION IS FURNISHED BY ME OR ANY VIOLATION OF PROVISIONS OF
{(BLOCK-2= 348.54 SQM)X12= 4182.48}+ THESE RULES OR PREVAILING NATIONAL BUILDING CODE IS FOUND IN ANY OF THE
{(BLOCK-3,4& 5= 1281.27 SQM)X12=15375.24}, DRAWINGS AND DOCUMENTS, SIGNED BY ME ANDSUBMITTED TO THE SANCTIONING
AUTHORITY FOR OBTAINING SANCTION.
{(BLOCK-6= 406.21 SQM.)X12= 4874.52 SQM}
9) TENEMENT AREA:
BLOCK-1: A) 61.72 SQM, B) 55.57 SQM, C) 62.38 SQM, D) 54.91 SQM, E) 54.91 SQM,
F) 54.81 SQM.
BLOCK-2: A) 85.70 SQM, B) 85.70 SQM, C) 54.02 SQM, D) 54.02 SQM,
BLOCK-3: A) 56.95 SQM, B) 58.41 SQM, C) 57.03 SQM, D) 79.11 SQM, E) 79.11 SQM
BLOCK-4: A) 56.95 SQM, B) 58.41 SQM, C) 57.03 SQM, D) 79.11 SQM, E) 79.11 SQM TAPAS KR. ROY
BLOCK-5: A) 56.95 SQM, B) 58.41 SQM, C) 57.03 SQM, D) 79.11 SQM, E) 79.11 SQM ENROLLMENT NO: ACHR/NKDA/10/00296, EXP. DATE: 04/02/2019
BLOCK-6: A) 101.43 SQM, B) 84.89 SQM, C) 54.77 SQM, D) 64.33 SQM,
SIGNATURE OF ARCHITECT
10) NO OF CAR PARKING SPACE = 310 NOS
CERTIFICATE OF STRUCTURAL ENGINEER:

F.A.R CALCULATION CERTIFIED THAT THE STRUCTURAL DRAWING AND DESIGN OF BOTH THE FOUNDATION &
SUPERSTRUCTURE OF THE BUILDINGS HAS BEEN MADE CONSIDERING THE SOIL TEST
REPORT, AS PER THE RULES AND REGULATIONS MADE UNDER THE ACT AND ALSO
TOTAL LAND AREA = 12056.67 SQM (E) CONSIDERING ALL POSSIBLE LOADS, SEISMIC LOAD AND THE MOMENTS GENERATED BY THE
PROPOSED STRUCTURE AS PER THE BUREAU OF INDIAN STANDARD AND NATIONAL
A) COVERED AREA OF GROUND FLOOR= 2901.20 SQM (A) BUILDING CODE OF INDIA AND CERTIFIED THAT IT IS SAFE AND STABLE IN ALL RESPECT
AND THESE PROVISIONS SHALL BE ADHERED TO DURING CONSTRUCTION.
B) COVERED AREA OF TYPICAL FLOOR= 29118.72 SQM(B)
C) TOTAL BUILT UP AREA= (A+B)= 32019.92 SQM (C)

D) EXEMPTION AREA FROM TOTAL BUILT UP AREA: 4994.61 SQM (D)


D/1) TOTAL STAIR AREA WITH L0BBY OF ALL BLOCK ALL FLOOR= 2011.54 SQM

D/2) TOTAL LIFT AREA OF ALL BLOCK ALL FLOOR= 559.68 SQM
DIPESH MAJUMDAR
ENROLLMENT NO: STER/NKDA/10/00101, EXP. DATE: 04/02/2019
D/3) TOTAL LIFT LOBBY AREA OF ALL BLOCK ALL FLOOR= 468.00 SQM
CERTIFICATE OF GEO TECHNICAL ENGINEER: DWG NO: RNPL/H/01/16/17
(AS PER RULES UP TO 10 PASSENGER =3 SQM PER LIFT PER FLOOR) DATE:
AS THIS BUILDING IS 15 METER AND /OR MORE IN HEIGHT AND/OR PLOT AREA MORE THAN
1500 SQM, AND/OR HAVING DEEP FOUNDATION/PILLING AND/OR BASEMENT I HEREBY SUBJECT: GROUND FLOOR
APPOINT SRI SANTOSH KUMAR CHAKRABORTY AS GEO TECHNICAL ENGINEER PLAN, UGR DETAILS, KEY
D/4) TOTAL PUMP ROOM & ELECTRICAL ROOM= 176.90 SQM PLAN, GATE DETAILS,
BOUNDARY DETAILS,
GYM & GAMES ROOM SECTION
D/5) PARKING AREA WITH CIRCULATION SPACE (COVERED PARKING)= 1778.49 SQM & ELEVATION ETC.
(AS PER RULES 25 SQM FOR EACH PARKING IN GROUND FLOOR) NAME OF GEOTECHNICAL ENGINEER: SANTOSH KR CHAKRABORTY SCALE: 1:100, 1:1000, 1:50
ENROLLMENT NO: GTER/NKDA/10/00006, EXP. DATE: 29/09/2016 1:25
PROPOSED F.A.R= (C-D) E = {(32019.92 - 4994.61) 12056.67} = 2.241 NAME OF ELECTRICAL ENGINEER: UTPAL SAHA SHEET NO: 1
ENROLLMENT NO: ELER/NKDA/10/00010, EXP. DATE: 24/03/2018
DRAWN BY: S.GHOSH
12) REQUIRED GREEN OPEN SPACE= 5.0685% OF PLOT AREA = 611.09 SQM
NAME OF PHE ENGINEER: BASUDEB DAS CKD BY: T.ROY
13) PROVIDED GREEN OPEN SPACE= 5.1 SQM (14.8307%)
ENROLLMENT NO: PHER/NKDA/10/00004, EXP. DATE: 25/05/2019