For the shown fig. an existing concrete beam in upper roof slab at axis 2. its required
to hold an additional elevator load with 8 ton in the middle span. Check the safty of
this beam only and take the nessary engineering action for this beam ( the clear height
of floor under beam not less than 2.20 m).
Examiners Signature
Dr. Ghada Diaa , Prof. Dr. Ahmed Ali and Prof. Dr. Hany Abdalla Page 6 of 20
Question (6): (40 Marks)
A old factory consists of one story as shown in the next figure with 8.0 m spans.
The slab th. was 28 cm with 42 cm drop panel. The client wants to add 4 new
floors and also increase L.L of the exisiting floor from 500 kg/m2 to be 1000
kg/m2. It is required to check the marked elements on plan of the factory to
carry the added loads from this modification as follows:
n Check the status of the two columns mentioned in plan to carry the new
floors ( safe or not) (4Marks)
n Check the status of the footings mentioned in plan to carry the new loads
( safe or not) (4Marks)
n Advise the client about your recommendation to modify the factory for
the clouded columns and footings show all available alternatives to solve
this issue. ( we need only sketches)
ﻣﻄﻠﻮب ﻛﺎﻓﮫ اﻟﺤﻠﻮل اﻟﻤﻤﻜﻨﮫ – اذﻛﺮ ﻣﻊ اﻟﺮﺳﻢ ﻓﻘﻂ (8Marks)
n For the existing roof and due to increase of L.L the marked locations show
in slab was subjected to an increase of 26.5% for positive moment location
from the original moments. Its required to take an actions for this issue
( need calculation and sketch ) (8 Marks)
Using Data:
- Fcu = 300 kg/cm2 and Fy= 4000 kg/cm2
- Soil bearing capacity = 1.75 kg/cm2.
- L.L= 1000 kg/m2, flooring 250 kg/m2 and no internal wall
- H floor = 3.25 m b wall = 25 cm wall density = 1.8 t/m3
- Column type C1 --- 30*60 cm has 10T16 vertical reinforcement with 6R8/m
stirrups
- Column type C5 --- 70*70 cm has 32T16 vertical reinforcement with 8R8/m
stirrups
Examiners Signature
Dr. Ghada Diaa , Prof. Dr. Ahmed Ali and Prof. Dr. Hany Abdalla Page 9 of 20
- Isolated type F1 -- 275*245*30 cm plain concrete and 215*185*50 cm
reinforced concrete with 6T16/m in two directions.
- Isolated type F5 -- 415*415*30 cm plain concrete and 355*355*60 cm
reinforced concrete with 8T18/m in two directions.
Roof plan
Examiners Signature
Dr. Ghada Diaa , Prof. Dr. Ahmed Ali and Prof. Dr. Hany Abdalla Page 10 of 20
Footing plan
Columns plan
Examiners Signature
Dr. Ghada Diaa , Prof. Dr. Ahmed Ali and Prof. Dr. Hany Abdalla Page 11 of 20
fcu & fy in N/mm2 for all Equations
d=c1Ö(Mu / fcu b) , As =Mu /fy j d ,
Examiners Signature