X3-Hybrid Series

User Manual
5.0kW - 15.0kW

EN
Copyright Declaration
The copy right of this manual belongs to Solax Power Network Technology(Zhe jiang) Co. , Ltd.
(Solax Power Co. , Ltd. ) . Any corporation or individual should not plagiarize, partially or fully
ADD: No. 288 Shizhu Road, Tonglu Economic Development Zone, copy (including software, etc. ) , and no reproduction or distribution of it in any form or by any
Tonglu City, Zhejiang Province, China. means. All rights reserved. SołaX Power Network Technology (Zhe jiang) Co. , Ltd. reserves the
right of nal interpretation. The contents are subject to change without prior notice.
Tel: + 0571- 5626 0011
E-mail: info@solaxpower.com 614.00498.02
Contents

Contents
1 Note on this Manual ................................................. 03
1.1 Scope of Validity .................................................................... 03
1.2 Target Group .......................................................................... 03
1.3 Symbols Used .......................................................................... 03
1.3.1 Important Safety Instructions............................................ 04
1.3.2ExplanationofSymbols...................................................... 09
 1.3.3 CE Directives........................................................................ 11

2 Introduction...................................................................... 12
2.1 Basic Features.........................................................................12
2.2 Electrical Block Diagram of The System.........................12
2.3 Work Modes .............................................................................. 15
2.4 Dimension................................................................................17
2.5 Terminals of Inverter .............................................................17

3 Technical Data .................................................................... 19


3.1 DC Input . ................................................................................... 19
3.2 AC Output/Input................................................................... 19
3.3 Battery ........................................................................................ 20
3.4 Efficiency, Safety and Protection ..................................... 20
3.5 EPS(Off-grid) Output ........................................................... 21
3.6 General Data ............................................................................ 21

4 Installation .............................................................................. 22
4.1 Check for Transport Damage ...................................................... 22
4.2 Packing List .................................................................................................. 22
4.3 Installation Precautions ..................................................................... 24
4.4 Tool Preparation ...................................................................................... 25
4.5 Installation Site Conditions ............................................................ 27
4.5.1 Installation Carrier Requirements ............................................. 27
4.5.2 Installation Requirements............................................................... 27
4.5.3 Installation Space Requirements................................................. 28
4.6 Mounting ...................................................................................................... 29

01
Contents Notes on this Manual

5 Electrical Connections ........................................................... 32 1 Notes on this Manual


5.1 PV Connection ......................................................................................... 32
5.2 Grid Port and EPS(Off-grid) Output Connection .......... 36 1.1 Scope of Validity
5.3 EPS(Off-grid) Block Diagram ......................................................... 37 This manual is an integral part of X3-Hybrid G4, it describes the
5.4 Battery Connection .............................................................................. 46 assembly, installation, commissioning, maintenance and failure of
5.5 Communication Connection ....................................................... 50 the product. Please read it carefully before operating.
5.5.1 Introduction to DRM Communication..................................... 50 X3-Hybrid-5.0-D X3-Hybrid-5.0-M X3-Hybrid-10.0-D X3-Hybrid-10.0-M
5.5.2 Introduction to Meter/CT Communication........................... 51
X3-Hybrid-6.0-D X3-Hybrid-6.0-M X3-Hybrid-12.0-D X3-Hybrid-12.0-M
5.5.3 COM Communication...................................................................... 54
5.5.4 Communication Connection Steps........................................... 56 X3-Hybrid-8.0-D X3-Hybrid-8.0-M X3-Hybrid-15.0-D X3-Hybrid-15.0-M
5.6 Grounding (mandatory) ....................................................................65 Note: "X3-Hybrid G4"Series refers to the energy storage inverter
5.7 Monitoring Connection .................................................................... 68 that supports photovoltaic grid-connected.
5.8 Check All Below Steps Before Starting Inverter...............................71 “5.0"means 5.0kW.
5.9 Inverter Operation ................................................................................. 71 “D" means "DC switch", "M" means externally connected.
X3-Matebox, built-in DC switch, BAT circuit breaker, AC and EPS(Off-grid)
circuit breaker, which can reduce the cost of customers on
6 Firmware upgrading...........................................................................................73 accessory. And pre-installed wiring cables and device can get rid
of the complicated wiring work.
7 Setting ......................................................................................... 77 Keep this manual available at any time.
7.1 Control Panel ............................................................................ 77 1.2 Target Group
7.2 Menu Structure ...................................................................... . 78 This manual is for quali ed electricians.The tasks described in this
7.3 LCD Operation .......................................................................................... 79 manual only can be performed by quali ed electricians.
1.3 Symbols Used
The following types of safety instructions and general information
8 Troubleshooting ............................................................ 105 appear in this document as described below:
8.1 Trouble Shooting ..................................................................105
Danger!
8.2 Routine Maintenance ......................................................... 111
“Danger" refers to a dangerous situation that, if not
avoided, will result in a high level of risk such as serious
injury or even death.
9 Decommissioning ........................................................ 112
9.1 Disassemble the Inverter ...................................................112 Warning!
9.2 Packaging ................................................................................112 "Warning" indicates a dangerous situation, which,
if not avoided, may result in serious injury or death.
9.3 Storage and Transportation ..............................................112
9.4 Waste Disposal .......................................................................................112 Caution!
“Caution” indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.

10 Disclaimer ....................................................................................... 113 Note!


“Note” provides tips that are valuable for the optimal
operation of our product.

02 03
Safety Safety

Warning!
Danger! The inverter can not be operated when it is running.

Danger to life due to high voltages in the inverter!


The personnel responsible for the installation, electrical Warning!
connection, debugging, maintenance and fault handling
Risk of electric shock!
operation of this product need to be trained, master the correct
operation method, have the corresponding electrician
qualification and safety operation knowledge.
Strictly follow relevant safety specifications for product installation
and testing. During installation, operation or maintenance, please
Caution! read carefully and follow the instructions and precautions on the
When the inverter is working, it is strictly forbidden to touch the inverter or user manual. If the operation is incorrect, it may cause
shell. The temperature of the shell is high and there is a risk of personal and property losses. Please keep the user manual properly
scalding. after use.

This inverter can only use the accessories sold and recommended by
Caution! SolaX, otherwise it may cause fire, electric shock or casualties.
Without the authorization of our company, you may not open the
Radiation may be harmful to health!
inverter cover or replace the inverter parts, otherwise the warranty
Do not stay for a long time and keep at least 20 cm away from
promise of the inverter will be invalid.
the inverter.
The use and operation of the inverter must be carried out in
Note! accordance with the instructions in this manual, otherwise this
protection will fail and the warranty of the inverter will also fail.
Ground PV system. During working, the inverter surface temperature may exceed 60 °C ,
Finish PV modules and photovoltaic system grounding in please make sure the inverter cools down before touching, and
accordance with local requirements to achieve optimal make sure children can not touch.
protection of systems and personnel.
When exposed to sunlight, photovoltaic arrays generate dangerous
high DC voltages. Please follow our instructions, otherwise it will be
Warning! life-threatening.
Ensure that the input DC voltage is below the inverter limit.
All DC and AC power sources must be disconnected from the
Excessive DC voltage and current may cause permanent
inverter for at least 5 minutes before any wiring or electrical
damage or other losses to the inverter, which is not covered by
operation is performed on the inverter to ensure complete isolation
the warranty. of the inverter and avoid electric shock.

Warning!
Before performing maintenance, cleaning or operation on the
circuit connected to the inverter, authorized maintenance
personnel must first disconnect the AC and DC power supplies
of the inverter.

04 05
Safety Safety

If the building installed with external light protection device is far


A photovoltaic module used on the inverter must have a IEC61730A away from the inverter location, in order to protect the inverter from
rating, and the total open circuit voltage of the photovoltaic string / electrical and mechanical damage, the inverter should also install an
array is lower than the maximum rated DC input voltage of the external lightning protection equipment.
inverter. Any damage caused by photovoltaic over voltage is not
covered by warranty. In order to protect DC system, two-stage surge protection equipment
is needed between DC cable of inverter and photovoltaic equipment
Installation position should be away from wet environment and
corrosive substances. module.

After the inverter and power grid cut off the PV power supply, there In order to protect the AC system, the level 2 surge protection
will be a certain amount of residual current in a short time, be equipment should be installed at the AC output, located between
cautious or it may lead to serious personal injury and even high risk
the inverter and the grid. Installation requirements must comply with
of death. Use a multimeter (impedance at least1 MΩ) to measure the
voltage between the UDC and the UDC- to ensure that the inverter IEC61643-21 standard.
port is discharged below the safe voltage before starting operation
(35 VDC). All DC cables shall be installed in a distance as short as possible, and
the positive and negative cables of the same input need to be
bundled together to avoid causing loops in the system. Minimum
distance installation and binding requirements also apply to auxiliary
Ø Surge protection devices (SPDs) for PV installation grounding and shielding grounding conductors.

Warning!
Over-voltage protection with surge arresters should be
provided when the PV power system is installed.
The grid connected inverter is fitted with SPDs in both Ø Anti-lslanding Effect
PV input side and MAINS side.
The islanding effect means that when the power grid is cut off, the
grid-connected power generation system fails to detect the power
Direct or indirect lightning strikes can cause failures. Surge is the main outage and still supplies power to the power grid. This is very dangerous
cause of lightning damage to most devices. Surge voltage may occur for the maintenance personnel and the power grid on the transmission
at photovoltaic input or AC output, especially in remote mountain line.
areas where long distance cable is supplied.
X3-Hybrid G4 series inverter’s use active frequency offset method to
prevent islanding effect.
Please consult professionals before installing SPDs.

The external lightning protection device can reduce the in uence of


direct lightning strike, and the lightning protection device can release
surge current to the earth.

06 07
Safety Safety

Ø PE Connection and Leakage Current 1.3.2 Explanation of Symbols


• All inverter’s incorporate a certified internal Residual Current Monitoring This section gives an explanation of all the symbols shown on the inverter
(RCM) in order to protect against possible electrocution and fire hazard and on the type label.
in case of a malfunction in the PV array, cables or inverter.
Symbols on the Inverter
There are 2 trip thresholds for the RCM as required for certification
(IEC 62109-2:2011).
The default value for electrocution protection is 30mA, and for slow
rising current is 300mA.

• The inverter, with built-in RCM, will exclude possibility of DC residual Operating Display
current to 6mA,thus in the system an external RCD (type A) can be used
(≥30mA).
Battery status

Warning!
High leakage Current! An error has occurred, please inform your installer immediately
Earth connection essential before connecting supply.

• A faulty ground connection can result in equipment failure, personal


and death injuries, and electromagnetic interference. Symbols on the Type Label
• Ensure correct according to grounding to IEC62109 and conductor
diameter according to STANDARD specification. Symbols
• Do not connect the grounding end of the equipment in series to
prevent multi-point grounding. CE mark.
• Electrical appliances must be installed in accordance with the wiring The inverter complies with the requirements of the
rules of each country. applicable CE guidelines.

For United Kingdom Type Approved


Safety
Regular Production
Sur veillance

TUV certified.
• The installation that connects the equipment to the supply terminals www.tuv.com
ID 1111227431

shall comply with the requirements of BS 7671.


• Electrical installation of PV system shall comply with requirements of
BS 7671 and IEC 60364-7-712. RCM remark.
• All protective devices cannot be changed.
• User shall ensure that equipment is so installed, designed and UKCA mark.
operated to maintain at all times compliance with the requirements of The inverter complies with the requirements of the
ESQCR22(1)(a). applicable UKCA guidelines.

Ø Battery Safety Instructions


UKNI mark.
SolaX X3-Hybrid G4 Series inverter should pair with high voltage battery, The inverter complies with the requirements of the
applicable UKNI guidelines.
for the speci c parameters such as battery type, nominal voltage and
nominal capacity etc., please refer to section 3.3.

Please refer to the matching battery speci cation for details.

08 09
Safety Safety

SAA certification.
This chapter describes the requirements of the European low voltage
regulations, including safety instructions and system licensing
Beware of hot surface. conditions, the user must comply with these regulations when
The inverter can become hot during operation. Avoid installing, operating, and maintaining the inverter, otherwise it will
contact during operation. cause personal injury or death, and the inverter will cause damage.

Danger of high voltages. Please read the manual carefully when operating the inverter .If you do
Danger to life due to high voltages in the inverter! not understand "danger", "warning", "caution" and the description in the
manual, please contact the manufacturer or service agent before installing
and operating the inverter.
Danger.
Risk of electric shock! Grid-connected inverter comply with low voltage directive (LVD)
2014/35/EU and Electromagnetic compatibility directive (EMC)
2014/30/EU.Detection of components is based on:
Observe enclosed documentation. EN 62109-1:2010 ;
EN 62109-2:2011;
IEC 62109-1(ed.1) ;
The inverter can not be disposed together with the IEC62109-2(ed.1) ;
household waste. Disposal information can be found in the EN 61000-6-3: 2007+A:2011;
enclosed documentation. EN 61000-6-1: 2007 ;
EN 61000-6-2: 2005 ;
Do not operate this inverter until it is isolated from battery,
mains and on-site PV generation suppliers.
For installation in photovoltaic module system, it is necessary to
Danger to life due to high voltage. There is residual voltage make sure that the whole system complies with the requirements of
existing in the inverter after powering off, which needs 5 min EC(2014/35/EU, 2014/30/EU, etc.) before starting the module (i.e. to
to discharge. Wait 5 min before you open the upper lid or start the operation).The assembly shall be installed in accordance
the DC lid. with the statutory wiring rules .Install and configure the system in
accordance with safety rules, including the use of specified wiring
methods. The installation of the system can only be done by
professional assemblers who are familiar with safety requirements
and EMC. The assembler shall ensure that the system complies with
the relevant national laws.

The individual subassembly of the system shall be interconnected by


means of the wiring methods outlined in national/international such as
the national electric code (NFPA) No. 70 or VDE regulation 0107.

10 11
Installation Introduction

2 Introduction Diagram B: N line and PE line separate wiring, M series inverter ;


(For most countries)
2.1 Basic Features
PV 1
X3-Hybrid G4 series is a high-quality inverter that can convert solar energy PV 2
into alternating current and store energy into batteries. X3-Hybrid G4
The inverter can be used to optimize self-consumption, stored in batteries CT
for future use or fed into the public grid. The way it works depends on Main Breaker/RCD
user preferences. It can provide emergency power during power outages. BAT Grid EPS(Off-grid)
N
2.2 Electrical Block Diagram of The System X3-Matebox
X3-Hybrid G4 series has two wiring schemes, one is for M series
E-BAR Grid
inverter connected to X3-Matebox, and the other is for D series
inverter.
There are different ways of wiring in different countries, one is to

Breaker
Breaker
connect N line with PE line, the other is to separate the line from the
PE line wiring, see below;
Battery Loads
EPS(Off-grid) loads

N-BAR for EPS(Off-grid) loads N-BAR for loads


Diagram A: N line and PE line separate wiring , D series inverter ;
(For most countries)
Diagram C: N line and PE line together, D series inverter;
PV 1 ( Applicable to Australia)
PV 2
X3-Hybrid G4
PV 1
CT
PV 2
Breaker Main Breaker/RCD X3-Hybrid G4
EPS(Off-grid) CT
BAT Grid
N Breaker CT 1 Main Breaker/RCD

BAT Grid EPS(Off-grid) CT 2


CT 3
N
Breaker
E-BAR Grid

RCD Breaker
E-BAR Grid
N
Breaker
Breaker

RCD

Battery
Distribution Box

Breaker
Breaker
EPS(Off-grid) loads Loads
Battery Distribution Box
N-BAR for EPS(Off-grid) loads N-BAR for loads EPS(Off-grid) loads Loads

N-BAR for EPS(Off-grid) loads N-BAR for loads

12 13
Introduction Introduction

Diagram D: N line and PE line together, M series inverter; 2.3 Work Modes
( Applicable to Australia)
X3-Hybrid G4 series, can be based on different needs, there are a variety of models.
Self Use
PV 1
The self-use mode is suitable for areas with low feed-in
PV 2
X3-Hybrid G4 subsidies and high electricity prices.
CT ① When the power of PV is sufficient
Active Charging or Discharge time period: PV will power the
CT 1 Main Breaker/RCD loads rstly, and surplus power will charge to the battery.
EPS(Off-grid)
If the battery is fully charged, then sell the surplus power to
BAT Grid
CT 2 the grid;( The inverter will limit the output if Feed-in limit or
CT 3 N
N
zero feed-in is needed )
E-BAR (PV>Load, PV →Load→Battery → Grid)

X3-Matebox E-BAR ③
② When the power of PV is insufficient
Grid ② Active Charging time period: PV will power the loads rstly ,
the remaining power will be taken from the grid , the battery
will not discharge at this time.
(PV<Load, PV + Grid → Load)

Breaker
Breaker

Active Discharge time period: PV+BAT will power the loads


together. If the power is still not enough, the remaining
power will be taken from the grid.
Battery EPS(Off-grid) loads Loads (PV<Load, PV + Battery + Grid → Load)
③ Without PV power
N-BAR for EPS(Off-grid) loads N-BAR for loads
Active Charging time period: The grid supplies the loads
and also can charge the battery;
(PV=0, Grid → Load + Battery)
Active Discharge time period: The battery will power the

home loads rstly. If the battery power is not enough ,the
remaining power will be taken from the grid. The inverter

will enter into the standby state.
(PV=0, Battery+Grid → Load )
Note! Battery min SOC can be set: 10%-100%;
The RCD on the gure represents a leakage protection Charge battery to min SOC can be set:10%-100%
device with a circuit breaker function.
Feed-in priority
The Feed-in priority mode is suitable for areas with high
• When power cuts suddenly, the inverter connects the N
feed-in subsidies, but has feed-in power limitation.
line of EPS(Off-grid) load with the ground through relay, ①When the power of PV is sufficient
providing a xed zero potential for EPS(Off-grid) load and Active Charging time period: First, PV supply power to the
ensuring the safety of electricity use by users. load, then charge the battery to the set capacity, and then
sell the power to the grid. If the local grid company limits

• Please control the inverter load and make sure it is the grid-connected power of the inverter, the excess energy
continues to charge the battery.
"output value" in "within " EPS(Off-grid) mode, otherwise (PV>Load, PV → Load → Battery→ Grid → Battery)

the inverter will stop and alarm overload fault". ②
Active Discharge time period: PV will power the loads rstly,
and surplus power will feed-in to the grid.
• Please confirm with the grid operator whether there are (PV>Load, PV → Load → Grid )
special regulations for grid connection. ②When the power of PV is insufficient
Active Charging time period: PV will power the loads rstly,
the remaining power will be taken from the grid. The battery
will not discharge.
(PV<Load, PV + Grid → Load)
Discharge time period: PV+BAT will power the loads together.
If the power is still not enough, the remaining power will be
taken from the grid.
14 (PV<Load , PV + Battery + Grid → Load) 15
Introduction Introduction

③Without PV power 2.4 Dimension


Active Charging time period: The grid will power
the home loads and also charge the battery;
(PV=0 , Grid → Load + Battery)
Active Discharge time period: The battery will 503mm 199mm
② power the home loads rstly. If the battery power

is not enough, the remaining power will be taken
from the grid. The inverter will enter into the
standby state.
(PV=0 , Battery+Grid → Load)
Battery min SOC can be set: 10%-100%;

503mm
Charge battery to min SOC can be set:10%-100%.

Backup mode
The back-up mode is suitable for areas with
frequent power outages.
Same working logic with “Self-use” mode. This
① mode will maintain the battery capacity at a

relatively high level. (Users' setting) to ensure

that the emergency loads can be used when
the grid is off. Customers no need to worry
about the battery capacity.
Battery min SOC can be set:30%-100%.
Charge battery to min SOC can be set:
30%-100%.


2.5 Terminals of Inverter

B C D E F G H
EPS(Off-grid) mode A
The EPS(Off-grid) is used when the power grid is off.
System will provides emergency power
through PV and batteries to supply power to the
household loads.
(Battery must be installed for this mode)
SHUT
①When the power of PV is sufficient
PV will power the loads rstly, and surplus power

will charge to the battery.

(PV>Load, PV → Load → Battery) EPS(Off-grid)

② ②When the power of PV is insufficient


The remaining power will be taken from the battery.
(PV<Load, PV → Load → Battery)
③ Without PV power
The battery will power the emergency loads until
the battery reached the min SOC, then the inverter I
K L M
will enter into the idle mode. J
A
(PV=0, Battery → Load)
EPS(off-grid) SOC-min condition is adjustable within
the range of 10%-25%.

Note: in the case of grid connection, all working modes work normally when the battery
SOC >5%. When the battery charge rate is below 5%, the PV or Grid will first charge the
battery SOC11%, and then return to the working mode selected by the user.
16 17
Introduction Technical Data

Object Description 3 Technical Data


A DC switch
3.1 DC Input
B PV connection port
X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
C Battery connection port Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M
D USB port for upgrading Max. recommended DC power [W] A:4000/B:4000 A:5000/B:5000 A:7000/B:5000 A:9000/B:6000 A:11000/B:7000 A:11000/B:7000
E Ethernet port Max. DC voltage [V] 1000 1000 1000 1000 1000 1000

Battery communication Nominal DC operating voltage [V] 640 640 640 640 640 640
F
Operating voltage typical [V] 180-950 180-950 180-950 180-950 180-950 180-950
G Meter/CT Port
Max. input current [A] 14/14 14/14 26/14 26/14 26/14 26/14
H Grid connection port Max. short circuit current [A] 16/16 16/16 30/16 30/16 30/16 30/16

I Ground connection port Start output voltage [V] 200 200 200 200 200 200
No. of MPP trackers 2 2 2 2 2 2
J Fans(only for X3-Hybrid-12.0-D/M and X3-Hybrid-15.0-D/M )
Strings per MPP tracker A:1/B:1 A:1/B:1 A:2/B:1 A:2/B:1 A:2/B:1 A:2/B:1
K External monitoring connection port
CAN are reserved ports / SHUT is a reserved port/
L
DRM Port(only for Australia)
M EPS(Off-grid) Output(main load connection port)

3.2 AC Output/Input
Warning !
X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
Qualified electrician required for the installation. Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M

AC Output

Nominal AC power[ W ] 5000 6000 8000 10000 12000 15000(PEA 14000)


Max. apparent AC power [ VA] 5500 6600 8800 11000 13200 15000
Rated AC voltage [V] 415/240; 400/230; 380/220
Rated grid frequency [Hz] 50/60
Max. AC current [A] 8.1 9.7 12.9 16.1 19.3 24.1
Displacement power factor 1 (0.8 leading...0.8 lagging)
Total harmonic distortion(THDi) < 3%

AC Input
Rated AC power [W] 10000 12000 16000 20000 20000 20000
Rated grid voltage(range) [V] 415/240; 400/230; 380/220
Rated grid frequency [Hz] 50/60

Max. AC current [A] 16.1 19.3 25.8 32.0 32.0 32.0

18 19
Technical Data Technical Data

3.3 Battery 3.5 EPS(Off-grid) Output


X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
Model Model
Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M

Battery type Lithium batteries EPS(Off-grid) rated power[VA] 5000 6000 8000 10000 12000 15000
Battery Full Voltage [V] 180-650 EPS(Off-grid) rated voltage [V] 400V/230VAC
Maximum charge/discharge flow [A] 30A Frequency[ Hz] 50/60

Communication interface CAN/RS485 EPS(Off-grid) rated current [A] 7.2 8.7 11.6 14.5 17.5 21.8
Reverse connection protection Yes EPS(Off-grid) Peak Power [VA] 7500,60s 9000, 60S 12000,60S 15000, 60S 15000, 60S 16500, 60S
Switching time [s] <10ms
Total harmonic distortion (THDv) <3 %

3.4 Efficiency, Safety and Protection 3.6 Generic Data


X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
Model X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M
MPPT efficiency 99.9% 99.9% 99.9% 99.9% 99.9% 99.9% Dimensions (W/H/D)[mm] 503*503*199
European efficiency 97.7% 97.7% 97.7% 97.7% 97.7% 97.7% Dimensions of Packing (W/H/D)[mm] 560*625*322
Maximum efficiency 98.2% 98.2% 98.2% 98.2% 98.2% 98.2% 30 30 30 30 30 30
Net weight [kg]
Max. battery charge efficiency Gross weight [kg] 34 34 34 34 34 34
(PV to BAT )(@ full load) 98.5% 98.5% 98.5% 98.5% 98.5% 98.5%
Heat dissipation treatment Natural Cooling Smart Cooling
Max. battery discharge efficiency
97.5% 97.5% 97.5% 97.5% 97.5% 97.5% Noise emission(typical) [dB] <40 <45
(BAT to AC)(@ full load)
Storage temperature range [°C] -40~+70
Security & Protection
Operating temperature range[°C] -35~+60 (derating at 45)
DC SPD Protection Integrated(TypeIII)
Humidity [%] 0%~100%
AC SPD Protection Integrated(TypeIII)
Altitude [m] <3000
Over/under voltage protection YES
Ingress Protection IP65
Grid protection YES
Protective Class I
DC injection monitoring YES
Cold standby consumption <5W
Back feed current monitoring YES
Over voltage category III(MAINS),II(PV, Battery)
Residual current detection YES
Pollution Degree III
Anti-islanding protection YES
Installation mode Wall mounted
Over load protection YES
Inverter Topology Non-isolated
Over heat protection YES
Communication interface Meter/ CT, external control RS485, Pocket series (optional), DRM, USB
Array insulation resistance detection YES

20 21
Installation Installation

4 Installation
Number Quantity Description
A 1 X3-Hybrid G4 series inverter.
4.1 Check for Transport Damage
B 1 Bracket
Ensure that the inverter is in good condition via transportation. If there
C☆ 1 Waterproof connector
is any visible damage such as cracks, please contact the dealer ☆
immediately. D 6 PV terminal (positive*3 , negative*3 )
E☆ 6 PV pin angle(positive*3 , negative*3 )

4.2 Packing List F☆ 12 10AWG European terminals


G☆ 1 OT terminal(inverter grounding)
Open the package and check the materials and accessories
H 5 (Expansion bolt, Gasket, Self-tapping bolt)
according to the following list.
I 1 M5 inner hexagon bolt
J 3 Communication line adapter (COM/Meter/BMS)
K 2 Battery connection terminals(positive*1, negative*1 )
L 5 RJ 45 terminals
A B C D M* 1 Manual
N 1 Quick Installation Guide
O 1 Warranty Card
P ▲ 1 Pocket WiFi (optional)
E F G H Q 1 Meter ( optional )
R 1 CT ( optional )

Note: The M series inverter in the accessory package does not include the “ C” \“ D” \“ E” \“ F”
and ”G“ accessories. The M series inverter must be used with X3-Matebox.
“L ” The inverter in Australia needs to be connected to DRM, which is 1 more
I J K communication line adapter than that in other countries.
L

X3-Hybrid Series
User Manual
5.0kW - 15.0kW

X3-Hybrid Series 5.0KW-15.0KW

EN

M N O P

Q R

22 23
Installation Installation

4.3 Installation Precautions 4.4 Tool preparation


The protection level of X3-Hybrid G4 series inverter is IP 65, so that the
inverter can be installed outdoors. Tool equipment
Check the installation environment and pay attention to the following
conditions when installing: Type Name Image Name Image
• Do not expose to strong light. Bit Φ10 DC Voltage
• Do not touch flammable building materials. Range ≥1100 V DC
• Do not approach flammable and explosive gases or liquids (e.g. where Hammer Multimeter
chemicals are stored). drill
• Do not touch cold air directly.
• Do not approach TV antenna or cable.
• Do not place in areas above 3000 meters above sea level. Crosshead M5
Socket
• Do not install in precipitation or high humidity, which may cause Torque wrench set
corrosion or damage Internal devices. screwdriver (Hexagon)
• Keep the system out of reach of children.
If the inverter is installed in a narrow area, be sure to reserve appropriate 0.5mm²~6mm²
Diagonal

Machine Installation Tools


space for heat dissipation. OT
The ambient temperature of the installation site is -35°C~60°C. terminals poliers
The maximum angle range of wall tilt ±5°. press clamp
Avoid direct sunlight, rain and snow weather.
Multifunction
Utility knife terminal
crimping
tool (RJ45)

wire stripper Marker


No direct sunlight No Rain Exposure No snow Lay up

Rubber Tape
hammer measure

Hexagon
Crimping
Stay away from Stay away from keys
combustibles
Direct Sunlight Rain Exposure Snow Lay up
antenna cables Tool

Euro
terminal
crimping Spirit level
tool
Individual
Protection Dustproof Protective
Tools Cover glasses

24 25
Installation Installation

4.5 Installation Site Conditions

Tool equipment 4.5.1 Installation Carrier Requirements


Do not install the inverter near flammable materials.
Type Name Image Name Image
Please install the inverter on a solid object that can withstand the weight
requirements of the inverter and energy storage system.
Individual Please be careful not to install the inverter in the plasterboard wall or
Safety Safety
Protection
Tool
gloves shoes similar to the residential places with poor sound insulation, so as not to
work with noise and interfere with the residents' life in the morning.

Type Name Image Requirement 4.5.2 Installation Requirements


Install the inverter at a maximum back tilt of 5 degrees, the inverter can
Equipment Breaker not be tilted forward, inverted, excessive back tilted or side tilted.
Grid port and EPS(Off-grid) port wiring
Preparation section (4.5.2)

Dedicated PV wire, line number


#12 AWG withstand voltage 1000V,
PV end
wire temperature resistance 105℃ fire
resistance grade VW-1

EPS
(Off-grid) Five-core cable
end wire ≤5°

Cable
Preparation
Grid end
Five-core cable
wire

Communi- Twisted pair with shield


cation lines

Battery
Conventional wire
Cable

PE Cable Conventional wire

26 27
Installation Installation

4.5.3 Installation Space Requirements 4.6 Mounting


Reserve enough space when installing inverter (at least 300mm) for heat
dissipation. Ø Preparation

Please prepare the following tools before installation.


≥300mm Reserved space dimensions of
installation

Position Min Distance


≥300mm ≥300mm Left 300mm
Right 300mm
Up 300mm Installation tools: screwdriver, wrench, Φ10 drill, rubber hammer, socket
Down 500mm wrench set and Hexagon keys.

≥300mm Ø Step 1: Fix the wall bracket to the wall

First find the expansion screw and the wall bracket in the accessory bag,
as shown below:
For multi-inverter installation scenarios, the inline installation method is
recommended; when the space is insufficient, the recommended method of It consists of four parts
installation in the form of "products"; it is not recommended to install multiple
inverters in stacks. If you choose stack installation, please refer to the installation
separation distance below.

Expansion bolts, Tapping screws, nut, Gasket Gasket Bracket


≥300mm ≥300mm

a) Use a marker to mark drilling holes of the bracket on the wall.


≥300mm ≥300mm ≥300mm b) Drill holes at marked spots with depth of 65mm.

≥1000mm ≥1000mm

≥300mm ≥300mm ≥300mm

≥500mm ≥500mm

28 29
Installation Installation

Ø Step 3: Tighten the inverter and bracket


m
80.00 m e) Hang the buckle on the inverter to the corresponding position of the
backplane;
f ) Use the inner hexagonal wrench to tighten the inner hexagonal screw
on the right side of the inverter.

Φ10 Drill
(Depth: 80 mm)
b)
Ø Step 2: hang the inverter on the bracket
c) Insert expansion bolt into the hole, use rubber hammer to knock the
expansion screw bolt into the wall;
d) The bracket is aligned with the screw uses the inner hexagonal wrench to
e)
screw the tapping screw until the expansion bolt "bang" is heard.

Expansion bolts, Tapping screws,

Hammer
c)

f)

Inner hexagonal wrench


nut, Gasket, (Torque:1.2±0.1 N· m)

d)

30 31
Electrical Connections Electrical Connections

5 Electrical Connections Ø Connection step


The PV port wiring of X3-Hybrid G4 M series inverter has been
5.1 PV Connection completed. For speci c installation details, please refer to the X3-
X3-Hybrid G4 series inverter have two PV inputs. Please select Matebox Quick Installation Guide, the D series needs to be wired
photovoltaic modules with good performance and quality assurance. according to the following steps.
The open circuit voltage of the module array should be less than the
maximum PV input voltage specified by the inverter, and the working Step 1. Turn off the DC switch, connect the PV module, prepare a 12AWG
voltage should be within the MPPT voltage range. PV cable, and find the PV (+) terminal and PV (-) terminal in the package.
Table 1: Maximum input voltage limit
X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M
Positive PV pin
Max. DC input voltage 1000V
Negative PV pin
Positive terminal
Warning!
PV cable PV pin Negative terminal
The voltage of photovoltaic modules is very high, and is
dangerous voltage. When wiring, please follow the safe
electricity regulations. Step 2. Use a wire stripper to strip the 7mm insulation layer of the wire end.

Note!
Please do not make PV positive or negative ground!

mm
7.0
Note! Wire stripper
The following PV module requirements need to be applied to
each input range: Step 3. Tighten the cable with the insulation layer stripped and insert it into
1. Same model the metal terminal (see Figure 1), make sure all wires are inserted Into the
2. Same quantity metal terminal (see Figure 2).
3. The same queue
4. The same angle

Note!

x
X3-Hybrid G4 series inverters do not support the following PV
module connection modes.
+ + +
- PV1
- Positive PV pin
Negative PV pin
+ + PV2 Figure 1
- - -
PV Inverter


X3-Hybrid G4 series inverter support the following PV module
connection modes. Positive metal terminal
+ + + Negative metal terminal
- - PV1
Figure 2
+
+- PV2
-
PV Inverter
32 33
Electrical Connections Electrical Connections

Step 4. Tighten the PV pin needle and the wiring harness to make the The following is the location of the inverter's positive and negative
connection tight without looseness. (PV-/PV+) ports.
Note: Before inserting the PV terminal, please turn on the switch of
the PV module and use a multimeter to measure the positive and
negative poles of the PV terminal port to prevent reverse
connection.

Crimping Tool

Multimeter
DC Voltage
Range ≥1100 V DC

Step 5. The PV joint is divided into 2 parts - the plug and the fastening head.
Insert the cable through the fastening head and the opposite plug.
Note that the red and black lines correspond to differentof plugs. Finally,
force the cable pair into the plug, will a "click" sound,which indicates that
the connection is complete. PV1+
PV1+
PV 2+
Positive terminal
PV1-
PV1-
PV 2-

Schematic diagram of the inverter PV connected.

Negative terminal

Step 6. Tighten the fastening head and into insert the corresponding
positive and negative (PV-/PV+) ports of the inverter.

PV+

Positive

PV-

Negative

34 35
Electrical Connections Electrical Connections

5.2 Grid Port and EPS(Off-grid) Output Connection 5.3 EPS(Off-grid) Block Diagram
X3-Hybrid G4 series inverter has an EPS(Off-grid) function. When the
X3-Hybrid G4 series inverter are three-phase inverter. Suitable for rated grid is connected, the inverter outputs go through the Grid port, and
voltage 380/400/415V, frequency 50/60Hz. Other technical requests should when the grid is disconnected, the inverter outputs go through the
comply with the requirement of the local public grid. EPS(Off-grid) port.
The EPS(Off-grid) function can be connected to part of the load, Please
refer to the following diagram for the wiring.
Ø Grid port connection If you want to save installation time, you will need an accessory. If you
need a solution, please contact our sales staff.
Grid Cable and Micro-breaker recommended
X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
Model Ø EPS(Off-grid) wiring
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M
Cable (copper) 4~6mm² 4~6mm² 4~6mm² 5~6mm² 5~6mm² 5~6mm²
For to different local wiring rules, please refer to the diagram below
Micro-Breaker
Please select the appropriate wiring method according to local wiring
20A 20A 32A 40A 40A 40A
rules.

EPS(Off-grid) Cable and Micro-breaker recommended Diagram A: N line and PE line separate wiring , D series inverters ;
(For most countries)
X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D
Model
Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M

Cable (copper) 4~6mm² 4~6mm² 4~6mm² 4~6mm² 4~6mm² 4~6mm² PV 1


Micro-Breaker 16A 16A 20A 25A 32A 40A PV 2
X3-Hybrid G4
CT
Breaker Main Breaker/RCD

The load should not be directly connected to the inverter. BAT Grid EPS(Off-grid)
N

Breaker
E-BAR Grid

RCD

Breaker
Breaker
Battery
Distribution Box
EPS(Off-grid) loads Loads

N-BAR for EPS(Off-grid) loads N-BAR for loads


Figure: Wrong connection of load and inverter

36 37
Electrical Connections Electrical Connections

Diagram B: N line and PE line separate wiring, M series inverters ; Diagram D: N line and PE line together, all load connection EPS(Off-grid)
(For most countries) scheme; ( Applicable to Australia)

PV 1
PV 2 PV 1
X3-Hybrid G4
PV 2
CT
X3-Hybrid G4
Main Breaker/RCD CT

BAT Grid EPS(Off-grid) Main Breaker/RCD


CT 1
N
BAT Grid EPS(Off-grid)
CT 2
X3-Matebox CT 3 N
N
E-BAR Grid E-BAR
E-BAR
X3-Matebox Grid

Breaker
Breaker

Breaker
Breaker
Battery Loads
EPS(Off-grid) loads
Battery EPS(Off-grid) loads Loads

N-BAR for EPS(Off-grid) loads N-BAR for loads


N-BAR for EPS(Off-grid) loads N-BAR for loads

Diagram C: N line and PE line together, D series inverters;


( Applicable to Australia)

PV 1
X3-Matebox is a convenient wiring accessory. Please refer to 
PV 2
X3-Hybrid G4 X3-Matebox for details. If you need to purchase X3-Matebox, please
CT contact us.
Breaker CT 1 Main Breaker/RCD

BAT Grid EPS(Off-grid) CT 2 The RCD on the gure represents a leakage protection
CT 3
N
device with a circuit breaker function.
To use X3-Matebox's Diagram B and Diagram D, you
need to set "X3-Matebox" to "Enable" in "Settings";
E-BAR Grid
Breaker
N
The Australian customer must shorten the N lines of the
Grid and the EPS(Off-grid) in the X3-Matebox.
RCD If your local wiring method does not follow the above
operation guide, especially the neutral wire, ground wire,
RCD wire, please contact our company before operation.
Breaker
Breaker

Battery Distribution Box


EPS(Off-grid) loads Loads

N-BAR for EPS(Off-grid) loads N-BAR for loads

38 39
Electrical Connections Electrical Connections

Ø EPS(Off-grid) load requirements Ø Grid and EPS(Off-grid) connection steps

Warning! Connection requirements


Ensure that the EPS(Off-grid) load rated power is within the
Note: Check the grid voltage and compare the voltage range
EPS(Off-grid) rated output power range, otherwise, the
(see technical data).
inverter will report an "overload" warning.
Disconnect the circuit board from all power sources to prevent electric
shock.
When “overload” occurs, adjust the load power to make sure it
is within the EPS(Off-grid) rated output power range, and the
The Grid and the EPS(Off-grid) ports of X3-Hybrid G4 M series inverter
inverter will automatically return to normal.
have been connected, for specific installation details, please refer to the
X3-Matebox Quick Installation Guide. And the D series needs to be
For non-linear loads, ensure that the inrush current power is
wired according to the following steps.
within the EPS(Off-grid) rated output power range.
When the configuration current is less than the maximum DC
input current, the capacity and voltage of lithium and lead
Step 1. Prepare a Grid cable (five-core wire) and an EPS(Off-grid) cable
acid will decrease linearly.
(four-core wire), and then find the European terminal and waterproof
The following table shows some common loads for your reference. cover in the accessory bag.
m
2m 2m
m
L=1 L=1
Note: Please check with the manufacturer for high-power inductive loads. L L

Power Instance
Common 10AWG Grid(Five-Core Cable) 10AWG EPS(Off-grid)(Four-Core Cable)
Content
equipment Equipment
Start Rated Start Rated

100W 100VA 100VA


Resistive load X1 X1 (W) (W)
Incandescent Incandescent
lamp lamp

10AWG Euro Terminal*10 Waterproof cover

Inductive load X 3~5 X2 450-750VA 300VA


150W (W) (W)
Fan Fridge Fridge

40 41
Electrical Connection Electrical Connection

Step 2. First remove the waterproof housing plug, and then the Grid and Step 3. Remove the 12mm insulation layer at the end of the wire. Insert
EPS(Off-grid) cables through the waterproof housing corresponding to the European-style terminals respectively, and make sure that the stripped
the Grid and EPS(Off-grid) ports. ends are inserted into the European-style terminal, and finally use
crimping pliers to press tightly.

Diagonal pliers

L L= 12 m m

m
2m
L L=1

Crimping Tool

※Note: Please press European


terminal into a 3.3.*3.3mm square.

Grid

EPS(Off-grid) Grid

d)
EPS(Off-gri

42 43
Electrical Connection Electrical Connection

Step 4. Find the location of the AC interface on the inverter, insert the Step 6. Tighten the waterproof fastening head.
crimped terminals into the UW10 terminals L1, L2,L3,N, and PE according
to the wire sequence, and use a flat-blade screwdriver to tighten the
screws. (Torque: 0.2±0.1N·m)

Torque screwdriver
( Torque: 1.5±0.1N·m)

Step 5. Install the AC waterproof cover, and tighten the screws on the four
sides of the waterproof cover with an Allen wrench.

Hexagon keys
( Torque: 0.8±0.1N·m)

44 45
Electrical Connection Electrical Connection

5.4 Battery Connection Ø Battery connection steps


Ø Connection requirements
Batter y por t connec tion line of the X3-H ybrid G4 M series
X3-Hybrid G4 series inverter charge and discharge system can be inverter is on the X3-Matebox,for specific installation details, please
equipped with high voltage lithium battery . refer to the X3-Matebox Quick Installation Guide It is necessary to
Please note that the maximum voltage of the battery should not wire the D series according to the following steps.
exceed 650 V, battery communication should be compatible with the
X3-Hybrid G4 inverter. Step 1. Prepare 8 AWG battery power line, find the DC plug (+), DC plug (-)
in the accessory bag.

Ø Battery Breaker 8 AWG


Before connecting the battery, a non-polar DC MCB must be installed to
ensure safety.
Before maintenance, the inverter need to be safely disconnected.

X3-Hybrid-5.0-D X3-Hybrid-6.0-D X3-Hybrid-8.0-D X3-Hybrid-10.0-D X3-Hybrid-12.0-D X3-Hybrid-15.0-D Power line BAT plug (+) BAT plug (-)
Model
X3-Hybrid-5.0-M X3-Hybrid-6.0-M X3-Hybrid-8.0-M X3-Hybrid-10.0-M X3-Hybrid-12.0-M X3-Hybrid-15.0-M

Voltage
Nominal voltage of DC breaker should be larger than maximum Step 2. Strip the insulation layer (length: 15mm) at one end of the power line.
voltage of battery.
Current[A] 32A

m
Ø Battery connection diagram 0m
15.
Diagonal pliers
com

Step 3. Insert the stripped cables into the DC plug (-) and DC Plug (+)
EPS(Off-grid)
respectively.

Non-polar
DC MCB
Communication line connection

Power line connection


CAN/RS485
- +

DC plug (-) DC plug (+)

... ...

Spring

High voltage lithium battery


Note: Cavity
When using SolaX battery, it is recommended to use the number of
battery control (T-BAT-5.8) is 1, the number of battery modules
(HV11550) is 1-4; the number of battery control (Mc0600) is 1, the
number of battery modules (HV10230) is 2-4.
The cable must pass through here
46 47
Electrical Connection Electrical Connection

Step 4. Press down on the spring by hand, you can hear a click sound, Ø Communication connection
then push the ends together, and tighten the screw joints.
BMS port definition
The communication interface between the inverter and the battery uses
the waterproof connector with RJ 45.
Spring
Spring
1) White with orange stripes
2) Orange
1 2 3 4 5 6 7 8
3) White with green stripes
4) Blue
5) White with blue stripes
Click ! 6) Green
7) White with brown stripes
8) Brown

1 2 3 4 5 6 7 8

X X X BMS_CANH BMS_CANL x BMS_485A BMS_485B

Note!
After the BMS communication between the battery
and the inverter is finished, the battery will work
Step 5. Insert the battery power lines into the corresponding BAT port (+), (-) normally.
of the inverter.

Note: BAT port, not PV port!


Note: The positive and negative
wires of the battery are not
allowed to be reversed!

48 49
Electrical Connection Electrical Connection

5.5 Communication Connection 5.5.2 Introduction to meter/CT Communication

5.5.1 Introduction to DRM communication (AS4777 regulatory requirements) X3-Hybrid G4 inverter should work with an electric meter or current
sensor (CT for short) to monitor household electricity usage. The electricity
meter or CT can transmit the relevant electricity data to the inverter or
DRM requirements: platform, which is convenient for users to read at anytime.
Mode Requirement
Users can choose to use electric meters or CTs according to their needs.
DRM0 Operation disconnect device
Please note that the meter/CT brand required by SolaX must be used.
DRM1 Do not consume power
DRM2 Do not consume more than 50% of rated power
Note!
Do not consume more than 75% of rated power AND The meter or CT must be connected to the inverter, otherwise
DRM3 the inverter will shut down and alarm Solax "meter failure"alarm.
Source reactive power if capable
Smart meters must be authorized by Solax, third party or
Increase power consumption other companies, Unauthorized meter may be incompatible
DRM4 (subject to constraints from other active DRMs) with the inverter.

DRM5 Do not generate power Solax will not be responsible for the impact caused by the use
of other appliances.
DRM6 Do not generate more than 50% of rated power

Do not generate more than 75% of rated power AND Ø Electric meter connection diagram
DRM7
Sink reactive power if capable
com

Increase power generation


DRM8 (subject to constraints from other active DRMs)
EPS(Off-grid)

1 1 2 3 4 5 6 7 8
DRM4/8 Load
8 DRM1/5 DRM2/6 DRM3/7 +3.3V DRM0 GND GND
in out

L1
L2
L3
Remarks: N
PE
Currently only PIN6 (DRM0) and PIN1 (DRM1/5) are functional, other Household Meter
Meter1
PIN functions are under development. Grid (three-phase meter)
in out
If the user has other power generation
equipment (such as inverter) at home and
wants to monitor both, X3-Hybrid G4 inverter
provides Meter2 communication function to Other power
Meter2
monitor the power generation equipment. (three-phase meter) generation equipment
For more information, please contact SolaX.

Note: If you want to connect the meter, please ground the GND terminal of the Meter1.

50 51
Electrical Connection Electrical Connection

Ø CT Connection Note for CT connection:

The current sensor measures the current on the live wire between the Note!
inverter and the public grid. • Do not place the CT on the N wire or ground wire.
• Do not put CT on the N line and L line at the same time.
• Do not place the CT on the side where the arrow points to
CT connection diagram the inverter.
• Do not place the CT on non-insulated wires.
• The cable length between CT and inverter should not
com exceed 100 meters.
• After CT is connected, prevent the CT clip from falling off.
It is recommended to wrap the CT clip around in circles with
insulating tape.

Grid Loads
1 2 3 4 5 6 7 8

L1 CT1-1 CT1-2 CT1-3


L2 1 1 2 3 4 5 6 7 8
L3
N

Household Meter 8 CT1-1 CT2-1 CT3-1 485A 485B CT3-2 CT2-2 CT1-2

Note:The arrow on the CT Meter/CT port is at the


must point at the public bottom of the inverter.
grid.

Public Grid L Line


electricity
CT
Note!
Meter/CT
Only one of the Meter and CT connections can be selected.
Meter cable goes to pin terminal 4 and 5; CT1 cable to PIN
Terminal 4 and 5; CT2 cable to PIN Terminal 1 and 8; CT3 cable is
connected to terminals 3 and 6.

LCD settings
To select CT, you need to enter Use setting, then enter CT/Meter
Setting.

CT/Meter Setting
>Select
CT

52 53
Electrical Connection Electrical Connection

5.5.3 COM Communication Inverter communication control external equipment:

COM communication interface is mainly provided for customization


the second step of development use.The inverter supports the control
of external equipment or external equipment control through
communication.

For example, the inverter adjusts the working mode


of the heat pump and so on.

Ø Application occasion
COM is a standard communication interface, through which the
monitoring data of the inverter can be directly obtained. Also, external Adapter
Box
communication devices can be connected to carry out the secondary
development of the inverter. For specific technical docking, please
contact SolaX.

External communication equipment controls the inverter:

Ø COM PIN Definition

1 1 2 3 4 5 6 7 8

Date Read 8 Drycontact_A(in) Drycontact_B(in) +13V 485A 485B GND Drycontact_A(out) Drycontact_B(out)

Note!
Customers can communicate or control the inverter and external devices
through the COM interface. Professional users can use pins 4 and 5 to realize data
acquisition and external control functions. The communication protocol is
Date Read Modbus RTU. For details, please contact SolaX. If the user wants to use the inverter
dry contact to control external equipment (such as a heat pump), it can be used
Date Write
with SolaX's Adapter Box. For details, please refer to the Quick Installation Manual
Smart control device
of the Adapter Box.
(developing)

54 55
Electrical Connection Electrical Connection

5.5.4 Communication Connection Steps


Step 1. Prepare a communication cable, and then find the communication
adapter in the accessory bag. Diagonal pliers

m
Communication cable Waterproof connector with RJ 45 RJ 45 terminal 0m
.0
CAN 15
Step 2 . The inverter CAN/DRM/SHUT port communication line connection, CAN
need to remove the inverter cover plate. DRM
Shut down

Step 4. Insert the prepared communication cables into the RJ45 terminals
in sequence, and then use network cable crimping pliers to
press them tightly.

Torque screwdriver
( Torque: 1.2±0.1N·m)

com
Grid Multifunction terminal
CAN CAN LCD DRM
crimping tool (RJ45)

EPS(Off-grid)

1) White with orange stripes


2) Orange
1 2 3 4 5 6 7 8
3) White with green stripes
4) Blue
5) White with blue stripes
Step 3. Insert the communication cable through the communication
adapter, and peel off the outer insulation layer of 15 mm. 6) Green
7) White with brown stripes
8) Brown

Diagonal pliers

m
Meter/CT/BMS/COM 00m
15.

56 57
Electrical Connection Electrical Connection

Ø DRM communication cable


The DRM pin is defined as follows:

1 2 3 4 5 6 7 8

1 1 2 3 4 5 6 7 8

8 DRM1/5 DRM2/6 DRM3/7 DRM4/8 +3.3V DRM0 GND GND

Ø BMS communication cable

The BMS pin is defined as follows:

1 2 3 4 5 6 7 8

1 1 2 3 4 5 6 7 8

8 X X X BMS_CANH BMS_CANL x BMS_485A BMS_485B

Note!
The communication port on the lithium battery must be consistent with the
definition of pins 4, 5, 7, and 8 above;

58 59
Electrical Connection Electrical Connection

Ø METER/CT communication cable 2) One side of the finished cable, Waterproof connector with RJ45 is
inserted into the inverter, and one side of the RJ45 terminal is inserted
METER/CT pin is defined as follow: into the CT connection.

1 2 3 4 5 6 7 8

1 1 2 3 4 5 6 7 8

8 CT1-1 CT2-1 CT3-1 485A 485B CT3-2 CT2-2 CT1-2 EPS(Off-grid)

Note!
Only one of the Meter and CT connections can be selected.
Meter cable goes to pin terminal 4 and 5; CT1 cable to PIN
Terminal 4 and 5; CT2 cable to PIN Terminal 1 and 8; CT3 cable is
connected to terminals 3 and 6.

1) Users can customize the length of the CT communication cable. The


accessory package provides 1*RJ45 and 1*waterproof connector with Distribution box
RJ45 terminals.
When the CT cable is completed, connect the A terminal to the
"CT/METER" port of the inverter and tighten the waterproof screw, and
connect the B terminal to the RJ45 coupler.

Note!
When installing, pay attention to water resistance. All the
connected parts of CT must be put into the distribution cabinet.
A
B

60 61
Electrical Connection Electrical Connection

Step 5. Connect the DRM / CAN / SHUT communication cable, and Step 6. Lock the cover plate and tighten the fastening head.
insert the cable into the corresponding port.

Dongle

EPS(Off-grid)

CAN CAN DRM SHUT

Torque screwdriver
( Torque: 1.2±0.1N·m)

CAN CAN DRM SHUT

CAN CAN DRM SHUT CAN CAN DRM SHUT

62 63
Electrical Connection Electrical Connection

Step 7: Finally, find the corresponding COM, BMS, Meter, CT, CAN, DRM, 5.6 Grounding Connection (mandatory)
SHUT poets on the inverter and insert the communication cable into the
corresponding ports. The user must make two ground connections: one shell grounding,
and one equipotential grounding. This prevents electric shock.

COM
Note: If the PV end of the inverter is not connected with earth, the
inverter will turn on a red light Inspect and report ISO Fault. This
inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm
monitoring.

Ground wire port of X3-Hybrid G4 M series inverter has been


connected, and the D series needs to be wired according to the
following steps.

Ø Ground connection steps


EPS(Off-grid)

Step 1. Prepare a one-core cable (12AWG), and then find the ground
terminal in the accessories.
12AWG

One-core cable (12 AWG) OT terminal Hexagon socket screws

CAN CAN DRM SHUT

Step 2. Strip the grounding cable insulation(length”L2), insert the


striped cable into the ring terminal, and then clamp it.

L1
m
3m
L 1+
L2=
Diagonal plier

64 65
Electrical Connection Electrical Connection

C Step 4. Find the ground connection port on the inverter, and screw the
Step 3. Insert the striped cable into OT terminal and tighten the terminal ground wire on the inverter with an M5 Allen key.
with a terminal crimping tool.

Grid

CAN CAN LCD DRM

EPS(Off-grid)

Leaking cable

Crimping Tool

Hexagon keys
Torque: 0.8±0.2N·m

66 67
Electrical Connection Electrical Connection

5.7 Monitoring Connection (Accessories) Step 2. Plug the Pocket WiFi Plus into the DONGLE port, use the screws
in the Pocket WiFi Plus accessory to tighten it.
The inverter provides a DONGLE port, which can transmit data of the
inverter to the monitoring website via Pocket WiFi Plus, Pocket 4G, Pocket
GPRS, and Pocket LAN. (If necessary, purchase products from SolaX)
Dongle
Ø DONGLE connection diagram

Solax Cloud

Router

Ø Wireless monitoring accessories connection steps


DONGLE port connection line of the X3-Hybrid G4 M series inverter is on
the X3-Matebox, for specific installation details, please refer to the
X3-Matebox Quick Installation Guide It is necessary to wire the D
series according to the following steps.
Step 1. Of the DONGLE port of the inverter needs to unscrew the screw
and take off the cover.

NGLE

Dongle
Dongle Phillips screwdriver
Torque: 1.0±0.2N·m
Cover
Phillips screwdriver
Torque: 1.0±0.2N·m

68 69
Electrical Connection Electrical Connection

5.8 Check All Below Steps Before Starting Inverter 5.9 Inverter Operation
Ø Before operation, check the inverter according to the following steps
Ø After the inverter is checked, the conduct the following a) Check that the inverter is well xed on the wall.
steps b) Ensure that all ground wires are well tightened.
Make sure that the inverter is fixed on the wall. c) Ensure that all DC and AC circuit breakers are disconnected.
d) Ensure that all ground wires are well tightened.
Ensure that all ground wires are grounded.
e) The AC output terminal is correctly connected to the mains.
Confirm that all DC lines and AC lines are connected. f ) Ensure that all photovoltaic panels and inverters are properly
Make sure the CT are connected. connected. Unused DC connectors should be blocked with caps.
Make sure the battery is well connected.
Turn on the Load switch and EPS(Off-grid) switch.
Ø Start the inverter
Turn on the battery switch.
Long press the “Enter “key for 5 seconds to exit the Off mode. Steps to start the inverter
(The mode is factory defaulted as Off Mode) - Turn on the AC switch between the X3-Hybrid G4 and the power grid.
- (Optional) Remove the locking screw from the DC switch.
- Turn on the DC switch between the PV string and the X3-Hybrid G4 if
there is any.
- Turn on the DC switch at the bottom of the X3-Hybrid G4 .
When the photovoltaic panel generates enough power, the inverter
will start automatically.
PV 1
- If the battery port of the X3-Hybrid G4 is connected to a battery, turn
PV 2
X3-Hybrid G4 on the auxiliary power switch of the battery and then the battery
CT switch.
Breaker Main Breaker/RCD
Check the status of the LED and LCD screen, the LED is blue, and the
LCD displays the main interface.
BAT Grid EPS(Off-grid) If the LED is not blue, please check the following:
N
- All connections are correct.
- All external disconnect switches are closed.
- The DC switch of the inverter is set to the "ON" position.
Breaker
E-BAR Grid

RCD The following are 3 different states of inverter operation, which


means that the inverter starts successfully.
Breaker
Breaker

Battery Distribution Box Waiting: When the DC output voltage of the photovoltaic panel is higher
than 100V (lowest starting voltage) and lower than 150V (lowest working
EPS(Off-grid) loads Loads
voltage), the inverter waits for checking.

N-BAR for EPS(Off-grid) loads


N-BAR for loads
Checking: The inverter will automatically detect the DC input. When the
DC input voltage of the photovoltaic panel is higher than 200V and the
Note: The RCD on the gure represents a leakage protection device with photovoltaic panel has enough energy to start the inverter, the inverter
a circuit breaker function. will enter the checking state.

70 71
Electrical Connection Firmware Upgrading

Normal: When the inverter is working normally, the green light is always on. 6 Firmware Upgrade
At the same time, the power is fed back to the grid, and the LCD displays
the output power. Ø Upgrade notes
Please read the following precautions before upgrading.

Warning!
If it is the rst time to boot, please follow the prompts to enter the setting
- In order to upgrade the firmware smoothly, if the DSP and
interface.
ARM firmware need to be upgraded, please note that ARM
firmware must be upgraded first, then DSP firmware!
- Please make sure that the category format is correct, do
not modify the firmware file name, Otherwise, the inverter
Warning!
may not work!
The input terminal of the inverter can be opened only when all
the installation work of the inverter has been completed. All
electrical connections must be performed by professionals in Warning!
accordance with local regulations. - For X3-Hybrid G4, ensure that the PV input voltage is
greater than 180V (upgrade on sunny days). please ensure
that the battery SOC is greater than 20% or the battery
input voltage is greater than 180V. Otherwise, it may cause
Note! serious failure during the upgrade process!
If it is the first time to operate the inverter, the system will
automatically display setup guide. Please follow the setup guide
to complete the basic inverter settings. Caution!
- If the ARM firmware upgrade fails or stops, please do not
unplug the U disk power off the inverter and restart it. Then
repeat the upgrade steps.

Caution!
- If the DSP firmware upgrade fails or stops, please check
whether the power is off. If it is normal, plug in the U disk
again and repeat the upgrade.

Ø Upgrade preparation

1) Please check the inverter version and prepare a U disk (USB 2.0/3.0) and
personal computer before upgrading.

Caution!
- Please make sure that the size of the U disk is smaller than
32G, and the format is FAT 16 or FAT 32.

72 73
Firmware Upgrading Firmware Upgrading

2) Please contact our service support through service@solaxpower.com to


obtain the firmware, and store the firmware in the U disk according to the
following path.

Update:
For ARM le: “update \ARM\618.00406.00_HYB_3P_ARM_V1.01.0710_usb”;
For DSP le: “update\DSP\618.00405.00_HYB_3P_DSP_V1.01.0710_usb”; U Disk

Ø Upgrade steps
Step 1. Please save the "Upgrade" firmware in your U disk first, and press
the "Enter" button on the inverter screen for 5 seconds to enter the OFF
mode.

Step 3. LCD operation, enter the upgrade interface "update", as shown


Long press for 5
below(a): Please press the up and down keys to select ARM, then press
seconds
down to set "OK", press the enter key to enter the
software version interface;
Step 2. Find the "update" port of the inverter, use a flat-blade screwdriver
or coin with the same width to remove the waterproof cover, and insert
Upgrade Selection Upgrade(ARM)
the U disk.
>ARM Cancel
DSP >OK

(a) (b)
Step 4. Please confirm the new firmware version again and select the
Flat-blade screwdriver or coin
Waterproof cover firmware to upgrade. The upgrade takes about 20 seconds.
(Port size: 12±2mm; (d) When it is completed, the LCD screen returns to the "Update" page.
Torque: 1.5±0.2N·m)
Update(ARM) Update(ARM) Update
>618.00406.00_Hybrid_ Upgrading---------25% >ARM
X3G4_ARM_V1.01 DSP
0710.usb

(c) (d) (e)

74 75
Firmware Upgrading Setting

Step 5. For DSP: Please wait for 10 seconds. When "Update" page shown 7 Setting
as below, press down to select "DSP" and then press Enter. Please confirm
the firmware version again and press Enter to upgrade. The upgrade
takes about 2 minutes.

Update Update(DSP) Update(DSP)


7.1 Control Panel
ARM >618.00360.00_Hybrid_ connect
>DSP X3G4_DSP_V1.01_07
10.usb

( f) (g) (h)

Update(DSP) Update(DSP)

DSP Erasing--------- Upgrading---------25%

(i) (j)

Step 6. After the upgrade is completed, the LCD screen displays" Upgrade
Successful" .
Upgrade(DSP)

Upgrade Successful Name Description


LCD Display inverter information on the LCD display.
(k) Screen
Blue light: The inverter is in normal state or EPS(Off-grid) mode.
Step 7. Plug off the U disk, press "Esc" to return to the main interface, and Blue ashing: The inverter is in the waiting, checking state
long press the enter key to exit the mode. or the system switch is off.
Off: The inverter is in a fault state.
LED Green: The battery communication is normal but the battery
Caution! Indicator MCB is disconnected, and the battery communication is
light normal and working normally.
- Please strictly follow each step from step 1-6, don't Green ashing: The battery communication is normal and
miss it. in an idle state.
- Please confirm the ARM/DSP firmware version on the Off: The battery does not communicate with the inverter.
USB flash drive. Red light on: The inverter is in a fault state.
Off: The inverter has no error.
ESC button: Return from the current interface or function.
Tip: If the display screen is stuck on "X3-Hybrid G4" after the upgrade,
Up button: Move the cursor to the upper part or increase the
please turn off the photovoltaic power supply and restart, and the inverter Key value.
will restart and return to normal. If not, Function
Down button: Move the cursor down or decrease the value.
please contact our service @solaxpower. com for help.
Enter button: Con rm selection.

76 77
Setting Setting

7.2 Screen Menu Structure 7.3 LCD Operation


1
System ON/OFF The main inter face is the default inter face, the inver ter will
automatically return to this interface when the system started up
successfully or not operated for a period of time.
Self Use
The information of the interface is as below. “Power” means the
Work Mode

2 Feed-in priority
instant output power; “ Today” means the power generated within
Backup mode Date&Time
Forced discharge the day. “Battery” means the left capacity of battery energy.
Manual Language
Forced charge
EPS(Off-grid) mode
Stopcharge&discharge
Self-use mode Power 0W
PV1 Feed-in Priority Today 0.0KWh
Battery 80%
System Status

PV2
Backup mode
3 Battery User settings Normal
Chrg & dischrg period
On-grid
Dry Contact
EPS(Off-grid)
User Password
Meter/CT
Safety Code

On-grid
Grid Parameters
Export Control
History Data

EPS(Off-grid)
Meter/CT Settings
4
Meter/CT-1
Self Test
Ø Menu interface
Meter/CT-2 Shadow Fix The menu interface is another interface for users to change settings
Error Logs Modbus or obtain information.
Matebox Setting
- When the LCD displays the main interface, click "OK" to enter this
interface.
Power Factor
- The user can select up and down the menu, and press the "OK" key
Pu Function to con rm.
settings

5
Advanced settings FVRT Function

Power limit

DRM Function Menu


Main Breaker Limit >System ON/OFF
Battery Heating Work Mode
System Status
Inverter EPS(Off-grid) Setting
6
About

Battery PhasePowerBalance

Internal Code Reset


Advance Password

COM Port Select


Manufactory settings
RlyEPSN Setting

Note:"  "This part of the content cannot be set by the end user.
Please contact the installer or Solax if necessary.

78 79
Setting Setting

Ø Menu main Ø Mode Selection


System ON/OFF
Self Use

Mode Select
Work Mode Feed-in priority

System Status Backup mode

History Data Manual

Settings
Mode selection, there are 4 working modes to choose from.
About Name Description
The self-use mode is suitable for areas with low feed-in subsidies
and high electricity prices.
① When the power of PV is sufficient
Active Charging or Discharge time period: PV will power the loads
rstly, and surplus power will charge to the battery .If the battery
is fully charged, then sell the surplus power to the grid;
( The inverter will limit the output if Feed-in limit or zero feed-in is
needed )
(PV>Load, PV →Load→Battery → Grid)
② When the power of PV is insufficient
Ø System ON/OFF Active Charging time period: PV will power the loads rstly ,the
remaining power will be taken from the grid , the battery will not
discharge at this time.
Self Use
(PV<Load , PV + Grid → Load)
“ON" means the inverter is in working state, and the inverter is in Active Discharge time period: PV+BAT will power the loads
the default state. together. If the power is still not enough, the remaining power
will be taken from the grid.
"OFF" means that the inverter stops running and only the LCD (PV<Load, PV + Battery + Grid → Load)
screen is on. ③ Without PV power
Active Charging time period: The grid supplies the loads and also
can charge the battery;
(PV=0, Grid → Load + Battery)
Active Discharge time period: The battery will power the home
loads rstly. If the battery power is not enough ,the remaining
System
power will be taken from the grid. The inverter will enter into the
Switch idle mode.
(PV=0, Battery+Grid → Load )
>OFF< Battery min SOC can be set:10%-100%;
Charge battery to min SOC can be set:10%-100%.

The Feed-in priority mode is suitable for areas with high feed-in
subsidies, but has feed-in power limitation.
①When the power of PV is sufficient
Active Charging time period: First, PV supply power to the load,
Feed-in then charge the battery to the set capacity, and then sell the
priority power to the grid. If the local grid company limits the
grid-connected power of the inverter, the excess energy
continues to charge the battery
(PV>Load, PV → Load → Battery→ Grid → Battery)
Active Discharge time period: PV will power the loads rstly, and
surplus power will feed-in to the grid.
(PV<Load, PV → Load → Grid )
80 81
Setting Setting

②When the power of PV is insufficient Ø System Status


Active Charging time period: PV will power the loads rstly, the
remaining power will be taken from the grid. The battery will not
discharge. PV1 a)
(PV<Load, PV + Grid → Load)
Discharge time period: PV+BAT will power the loads together. If the PV2 b)

System Status
power is still not enough, the remaining power will be taken from the
grid. Battery c)
Feed-in (PV<Load, PV + Battery + Grid → Load)
priority ③Without PV power On-grid d)
Active Charging time period: The grid will power the home loads and
EPS e)
also charge the battery;
(PV=0, Grid → Load + Battery) Meter/CT f)
Active Discharge time period: The battery will power the home loads
rstly. If the battery power is not enough, the remaining power will be
taken from the grid. The inverter will enter into the idle mode. System status contains six content:PV1/PV2/Battery/On-grid
(PV=0, Battery+Grid → Load)
(energy feed into or buy from the grid)and EPS and so on.
Battery min SOC can be set:10%-100%.;
Charge battery to min SOC can be set:10%-100%. Press up and down to select, press "Enter" to con rm the selection,
and press "ESC" to return to the menu.
The Back-up mode is suitable for areas with frequent power outages.
Same working logic with “Self-use” mode. This mode will maintain the
battery capacity at a relatively high level. (Users' setting) to ensure that a/b) PV1, PV2
Backup the emergency loads can be used when the grid is off. Customers no Here you can see the voltage, current and power of the pv1 and Pv2.
mode need to worry about the battery capacity. Photovoltaic panels respectively;
Battery min SOC can be set:30%-100%.
Charge battery to min SOC can be set:30%-100%.
The EPS(Off-grid) mode is used when the power grid is off. System will
provides emergency power through PV and batteries to supply power PV1 PV2
to the household loads. (Battery is necessary) >U 0.0V >U 0.0V
①When the power of PV is sufficient I 0.0A I 0.0A
PV will power the loads rstly, and surplus power will charge to the
EPS battery.(PV>Load , PV → Load → Battery)
(Off-grid) ②When the power of PV is insufficient
The remaining power will be taken from the battery.
(PV<Load , PV+ Battery → Load → Battery)
③Without PV power
c) Battery
The battery will power the emergency loads until the battery reached This status shows the battery condition of the system. Including
the min SOC, then the inverter will enter into the idle mode. battery voltage and battery current, Battery power, battery
(PV=0 , Battery → Load) capacity, battery temperature, BMS connection status. The
EPS(off-grid) SOC-min condition is adjustable within the range of meaning of the sign of battery current and power: "+" means
1 0%-25%;
charging; "-" means discharging.
Note: in the case of grid connection, all working modes work normally when the
battery SOC >5%. When the battery charge rate is below 5%, the PV or Grid will first
charge the battery SOC11%, and then return to the working mode selected by the Battery
Manual mode (manual mode), there are three options to choose from: forced U 400.0V
charging, forced discharge, stop charging and discharging (grid-connected 0 I -1.0A
power). P -400W

Work Select Work Select Work Select


>Manual >Manual >Manual
Forced Charge Forced Discharge Stop Cha&Discha

82 83
Setting Setting

d) On-grid Ø History Data


Here you can see the voltage, current, frequency, and power of the
On-grid a)
grid.

History Data
EPS b)

On-grid Meter/CT-1 c)
U 0.0V
I 0.0A Meter/CT-2 d)
P 0.0W
Error Logs e)

The history data contains five pieces of information: on-grid power of


the inverter, EPS power generation, power of the meter /CT and error
e) EPS Error logs.
Here you can see the inverter of voltage, current, frequency and
power when EPS,
Press up and down to select, press Enter to confirm selection, and press
ESC to return to the menu.

EPS
U a) On-grid
I Here is a record of the power capacity of the inverter connected to the
P grid today and the total.

On-grid
Output Today
f ) Meter/CT Output Total
Here you can see the data showing the meter or the CT. Input Today

Meter/CT b) EPS
>Meter/CT1-A 0000Kw Here you can see the EPS output of the inverter today and the total
Meter/CT1-B 0000Kw output.

EPS
Today
Total
00.0KWh

84 85
Setting Setting

c) Meter /CT-1 Ø User Settings


Here you can see the inverter's electricity sold, total electricity sold,
electricity bought from the grid and total electricity bought on that Date&Time a)
day.
Language b)
Meter CT-1
>FeedInToday: EPS mode c)
00.0KWh d)
Self-use mode

User settings
Feed-in Priority mode e)

Backup mode f)

d) Meter /CT-2 Chrg & dischrg period g)


Here you can see the total power output of the inverter for the day.
Dry Contact h)
Meter CT-2
>Output Today: User Password I)

00.0KWh
Here you can set the inverter time, language, working modeSOC,
charging and discharging time period and user password.

User Setting
Date Time
Language
e) Error Logs EPS mode
Here you can see the most recent six error messages.

Error logs a) Date time


This interface is for users to set the system date and time.
>No error

Date time

>2019 - 11 - 15
10 : 19

b) Language
This inverter provides multiple languages for customers to choose.

Language
>Select:
English

86 87
Setting Setting

c ) EPS Mute e)Feed-in Priority mode


Here you can choose whether the buzzer is turned on when the inverter In this mode, you can set the power reserve percentage of the minimum
is running in EPS mode. Select Yes, the buzzer mutes, select NO, EPS battery state, set whether the power can be taken from the mains side to
mode, the buzzer will sound once every 4s when the battery is fully charge the battery, and set the amount of power to charge the battery.
charged, the closer the battery is to the empty state, the higher the For example: set the reserved minimum SOC of the battery capacity to "10%",
buzzer will sound, to remind users to avoid battery loss . which means that when the battery has been discharged to 10% of the
battery capacity, the battery is not allowed to continue to discharge;

EPS Mute Charge battery to is set to 90%, indicating that the mains is allowed to
> Mute:
charge the battery at 90%.
Yes
Feed-in Priority mode Feed-in Priorty mode
>Min SOC: >Charge battery to
d) Self-use mode
In this mode, you can set the power reserve percentage of the minimum 90%
10%
battery state, set whether the power can be taken from the mains side to
charge the battery, and set the amount of power to charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"10%", which means that when the battery has been discharged to 10% of f ) Backup mode
the battery capacity, the battery is not allowed to continue to discharge; In this mode, you can set the power reserve percentage of the
When Charge from grid is set to "Enable", the utility power is allowed to minimum battery state, set whether the power can be taken from the
charge the battery; when set to “Disable”, the utility power is not allowed to mains side to charge the battery, and set the amount of power to
charge the battery; charge the battery.
Charge battery to is set to 90%, indicating that the mains is allowed to For example: set the reserved minimum SOC of the battery capacity to
charge the battery at 90%. "10%", which means that when the battery has been discharged to 10%
of the battery capacity, the battery is not allowed to continue to
discharge;

Self-use Mode Self-use Mode Charge battery to is set to 90%, indicating that the mains is allowed to
>Min SOC: >Charge from grid charge the battery at 90%.

10% Disable
Backup mode Backup mode
>Min SOC: >Charge battery to
Self-use Mode
>Charge battery to 10% 90%

90%

88 89
Setting Setting

g) Charge and discharge time Ø Advance settings


Here you can set the charge and discharge time period.
If two charging and discharging periods are needed, turn on the charging
and discharging period 2 and set the period. Safety Code a)
FVRT Function l)
Chrg&Dischrg Period Charge Period Grid Parameters b)
Power limit m)
>Charge Period >Charge Period Charge c)
DRM Function n)

Advanced settings
Start Time End Time Export Control d)
Main Breaker Limit o)

Advanced settings
Meter/CT Settings e) Battery Heating p)
Allowed Disc Period Allowed Disc Period
Self Test f) EPS(Off-grid) Setting q)
> Start Time > End Time
00:00 00:00 Shadow Fix g) PhasePowerBalance r)
Modbus h) Reset s)
Chrg&Dischrg Period2 Matebox Setting i) Advance Password t)
> Function j)
Power Factor
Enable Disable Pu Function k)

h) Dry Contact
When the user uses the inverter communication control external device All advanced settings can be set here, such as battery, grid, EPS, etc..
function, you can enter here to set the parameters of the external "Advanced" setting is generally customization and resetting for battery
response control. For the setting method, please refer to the user manual and grid. Each part has lower level parts.
of the compatible external device. Please contact your installer or factory and enter the installer password.
If the user uses the inverter dry contacts to control external devices (such
as heat pumps) through the Adapter box, please refer to the Adapter box
Advanced
quick installation manual to set the parameters here.
Safety Code
> Grid Parameters
Load Management
> Mode Select

Disable
* Please note that when the inverter DSP communication fails, all
I) User Password advanced settings will be hidden.
The default password for the end user is "0000", where you can reset the
new password and press the up/down key to increase or decrease the
value. Press "Enter" to confirm the value and jump to the next digit. When Advanced Charger
all passwords have been entered and confirmed, press "OK" to set the
DSP-COMM failed >Battery Awaken
password successfully. >Battery NO
User Password

0 0 0 0

90 91
Setting Setting

a) Safety Code Grid Grid


Users can set safety standards according to different countries. There are >OverFreq_L1 >UnderFreq_L1
now 1 standards to choose from. (There may be changes in the future,
please refer to the screen display) 0.0Hz 0.0Hz

Item Standard Country Grid Grid


1 ARN 4105 German
>Vac 10min Avg >OverVoltage_L2

0.0V 0.0V
OverVoltage_L1 Tovp_L2
c) Charger
UnderVoltage_L1 Tuvp_L2 Here the user can set the parameters of charger on this page, the
OverFreq_L1 inverter is compatible with both lithium battery. Users can set the
Tofp_L2
charge & discharge parameters.
UnderFreq_L1
Tufp_Fast For the detailed parameters, please refer to below table.
Vac 10min Avg
Grid Parameters

Reconnection Time
OverVoltage_L2
Grid Parameters
Checking Time Charger Charger
UnderVoltage_L2 W(Gra) Charge Max Discharge Max
OverFreq_L2 Current 25A Current 25A
OFPL_StartPoint
UnderFreq_L2 OFPL_SetRate
OverFreq_L2
OFPL_DelayTime
UnderFreq_L2 d) Export Control
UFPL_StartPoint
This feature allows the inverter to control the amount of electricity
Tovp_L1 UFPL_SetRate output to the grid.
Tuvp_L1 The factory value is the default and can be changed by the user.The
UFPL_DelayTime
user value set by setup must be less than the maximum.If the user
Tofp_L1 does not want to supply power to the grid, set it to 0.

Export Control
b) Grid Parameters
Here you can set the protection value of grid voltage and frequency. User value:
The default value is the specified value under the current safety 0W
regulations, and the user cannot change it.
e) Meter/CT Settings
The display content will be displayed according to the requirements The user needs to select the CT or electricity meter to connect the
of local laws and regulations, which are constantly increasing. Please inverter here. Select the address of the meter. CT does not need to select
refer to the contents displayed on the inverter screen. the address.

Grid Grid CT/Meter Setting CT/Meter Setting


>OverVoltage_L1 >UnderVoltage_L1 >Select >Meter 1Addr:
xxxxxxxx
0.0V 0.0V Meter

92 93
Setting Setting

f ) Self Test (only for CEI 0-21) g) Shadow Fix


The self test function allows users to test the following items. "Full test", Here, you can set the shadow tracking with four options, which are off,
"Ovp(59.S2) test"27. "Uvp (s1) test", "Uvp (27. s2) test", "Ofp (81> .S1) test", low, medium, and high.
"Ufp (81 <.S1) test", "Ufp (81> .S2) test", "Ufp (81 <.S2) test",
"Ovp10 (59. s1) test".
In the self-test interface, the user can select "all tests" or a single test item
for testing. Shadow Fix
Before testing, make sure that the inverter is connected to the grid. >Func Select
All tests take about 6 minutes. And it will display "Success" and then "Delivery".
For a single test item, it takes about a few seconds or minutes. >OFF<
Click "Test Report" to view the test results of all items.

h ) Modbus
ALL Test Here you select the baud rate of the external communication protocol,
Test report the default location of 19200 and 485 addresses.
Uvp(27.S1) test

>Ofp2(81>.S2)result >Ovp2(59.S2)result Modbus RTU/485 Modbus RTU/485


Ft: 51.50Hz Tt:1000ms Vt: 264.5V Tt: 300ms Baud Rate: RS485 Addr:
Fs: 0.00Hz To: 998ms Vs: 0.0V To: 200ms 115200
F0: 0.00Hz pass V0: 0.0V pass 1

>Ofp2(27.S2)result >Uvp2(27.S1)result
Vt: 92.0V Tt: 200ms Vt: 195.5V Tt: 400ms
Vs: 0.0V To: 196ms Vs: 0.0V To: 200ms
V0: 0.2V pass V0: 0.0V pass I ) Matebox Setting
If you want Matebox installed, you need to turn this feature on here.
>Ofp2(81>S1)result >Ufp2(81<.S1)result
Ft: 50.50Hz Tt: 100ms Ft: 49.50Hz Tt: 100ms
Fs: 0.00Hz To: 96ms Fs: 0.00Hz To: 98ms
F0: 0.2Hz pass F0: 0.02Hz pass Matebox Setting
>Select
>Ufp2(81<.S2)result >Ovp10(59.S1)result
Disable Enable
Ft: 47.50Hz Tt: 400ms Vt: 253.0V Tt: 600ms
Fs: 0.00Hz To: 3999ms Vs: 0.0V To: 598ms
F0: 0.02Hz pass V0: 0.0V pass

94 95
Setting Setting

j) Power Factor (applicable to specific countries, please refer to local grid k ) PU Function (applicable to specific countries, please refer to local
requirements) grid requirements)
Power Factor Power Factor
The PU function is a volt-watt response mode required by certain
Mode Select Mode Select
national standards such as AS4777.2. This function can control the
> Off < > < active power of the inverter according to the grid voltage.
Over-Excited
Selecting "Enable" means that this function is turned on and is the
default value.
Power Factor Power Factor
Select "Disable" to deactivate the function.
Mode Select Mode Select

> Under-Excited < > Curve <
PU Function PU Function
Power Factor >PuFunction Response V2
Mode Select
Enable 220.0V
> Q(u) <
PU Function PU Function
Response V3 Response V4

Mode Comment 250.0V 265.0V


Off -
Over-Excited PF value PU Function
Under-Excited PF value 3Tau
P1_PF (EU50549 only)
P2_PF (EU50549 only) 6~180S
P3_PF (EU50549 only)
P4_PF (EU50549 only)
Power 1
Curve Power 2 l ) FVRT Function(apply to50549)
Power 3 Here you can set the high and low enable or disable.
Power 4
PFLockInPoint (EU50549 only)
PFLockOutPoint (EU50549 only)
FVRT Function
3Tau Function Control
VoltRATIO 1 ( AS4777.2 only) Disable Enable
Q( u ) VoltRATIO 4 ( AS4777.2 only)
QURESPONSEV1 (EU50549 only)
m) Power limit
QURESPONSEV2 (EU50549 only)
Power limit function, the maximum power of the AC port can be set
QURESPONSEV3 ( (EU50549 only)
Q( u ) by percentage.
QURESPONSEV4 (EU50549 only)
K Value (CEI 0-21 only)
3Tau
Power Limit
QuDelayTimer >Proportion
Fixed Q Power Q Power 1.00

96 97
Setting Setting

● Reactive power control, reactive power standard curve cos φ = f(P) n) DRM function (applied to NZS4777.2)
The DRM function is a demand response method required by the
For VDE ARN 4105, the curve cos = f(P) should refer to curve B. The set
NZS4777.2 standard and is only applicable to NZS4777.2.
default value is shown in curve B.
The default value is "enable". Select "Disable" to disable this function.
For e8001, the curve cos = f(P) should be curve A. The set default value is
shown in curve A. DRM Function
>Function Control
For CEI 0-21, the default value of PFLockInPoint is 1.05. When Vac> 1.05Vn,
Pac> 0.2 Pn, curve cos cp = f(P) corresponds to curve B. Enable
cos φ
leading
0.9/0.95*
over-excited

o) Main Breaker Limit


Here you can set an open minimum current here.
1
0.2 0.5 1.0
under-excited

p/pEmax Main Breaker Limit


>Current
40A
0.9/0.95*
lagging
curve A

p) Battery Heating
Upper limit cosφ If the user needs the battery heating function, you can set it to turn on here,
0.9 0.95 and set the time period that needs to be heated, and the two time periods
inductive
inductive

can be set. (Only for batteries with heating function)


Power Upper
0.7 0.8 0.2 0.5 1.0 Battery Heating Battery Heating
0.2 0.3
capacitive

f (P)
capacitive

Power Lower f (P) >Func Select: >Heating Period 1


Start Time
Enable Disable 00:00
0.9 0.95
Lower limit
curve A curve B Battery Heating Battery Heating
>Heating Period 1 >Heating Period 2
End Time Start Time
● Reactive power control, reactive power standard curve Q= f(V) 00:00 00:00

Q V2s=1.10Vn
Battery Heating
Qmax V1s=1.08Vn=QuVlowRate
>Heating Period 2
V2i=0.90Vn
End Time
V2i=0.92Vn=QuVlowRate
V1s V2s 00:00
V2i V1i V

-Qmax

98 99
Setting Setting

q )EPS Setting Ø Manufactory Setting


User can set the frequency selection in the EPS mode here, and set the
minimum capacity reserved for battery discharge.

Manufactory settings
RlyEPSN Setting a)
EPS Setting EPS Setting EPS Setting
> Frequency >Frequency > Min SoC

50Hz 60Hz 10%

COM Port Select b)


r ) Phase Power Balance
This function controls the distribution of AC output power.
“Enable” means each phase will be divided according to the loads connected with
each phase. “Disable” means each phase power will be divided equally and “disable”
is the default setting value.
a) RlyEPSN Setting
three phase three phase The user needs to set whether the inverter is installed in Australia or
inverter inverter
load1
3KW
load2
4KW
load3
5KW
load1
3KW
load2
4KW
load3
5KW
Europe. When the inverter is off the grid, the N line and PE line of the
Phase Power Balance 3kw 4kw 5kw 4kw 4kw 4kw
circuit in Australia need to be connected; the N line and PE line of the
Function Control meter European circuit need to be separated .
meter
>Disable<
If 12kw AC power can be exported, each phase power will If 12kw AC power can be exported, each phase power will
be divided as above according to different loads connected
with each phase.
be divided equally as above and it is unrelated with the
loads connected with each phase.
RlyEPSN Setting RlyEPSN Setting
enable mode disable mode >function Control >function Control
Europe Australia
s ) Reset
Users can reset the reset error log, meter power ,inverter power, and
restore factory settings here.

Reset Error Log Reset Meter/CT_1 Reset Meter/CT_2


b) COM Port Select
>Reset >Reset >Reset
Here external communication protocol or external indoor screen of
Yes Yes Yes
the inverter can be set. When it is used for external communication
protocol, it can choose RS485 or MOBUS.
Reset INV Energy Factory Reset

>Reset >Reset RS485/MOBUS


Yes Yes
>RS485
MOBUS
t )Advance Password
Here you can reset the advanced password. "Set OK!" is displayed on
success, and “Setup Failed!” Will also displayed on failure.

Advance Password Advance Password


Set OK! Setup failed

100 101
Setting Setting

Ø About a) About
Here you can see some basic information of the inverter and battery.
such as the inverter and battery SN number, software version number,
and system run time.

About

Inverter SN >Inverter
Battery
Register SN
DSP
Inverter
ARM
On-grid Run Time
About
EPS Run Time
Bat_PS1 SN

Bat_PS2 SN
Battery Inverter
Bat_PS4 SN
Inverter Inverter
BatteryM Version
>Inverter SN >Register
01234560123456 01234560123456
BatteryS Version

Inverter code
Internal Code Inverter Inverter
BMS Code >DSP >ARM
2.07 1.03

Inverter Inverter
> EPS Runtime >On-grid runtime
Register1 SN: Represents the serial number of external monitoring 20.0H 45.9H
equipment, such as Pocket WiFi, Pocket LAN and Pocket GPRS.

102 103
Setting Troubleshooting

Battery
8 Troubleshooting
Battery Battery
> BatBrand:BAK > Bat-M SN 8.1 Troubleshooting
6S012345012345
This section contains information and procedures for
resolving possible problems with X3-Hybird G4, and
Battery Battery provides you with troubleshooting tips to identify and
> Bat-PS1 SN > Bat-PS2 SN solve most problems that may occur in X3-Hybrid G4. This
6S012345012345 6S012345012345
section will help you narrow down the source of any
problems you may encounter. Please read the
Battery Battery troubleshooting steps below.
> Bat-PS3 SN > Bat-PS4 SN Check the warning or fault information on the system
6S012345012345 6S012345012345 control panel or the fault code on the inverter information
panel. If a message is displayed, log it before doing
Battery Battery anything further.
Try the solutions indicated in the table below.
> BatteryM Version > BatteryM Version
2.01 2.01
Number
Overcurrent fault.
• Wait for a while to check if you're back to normal.
IE 001 TZ Protect Fault • Disconnect PV+ PV- and batteries, reconnect.
• Or ask for help from the installer if itcan not return to normal.

Internal Code • Check battery input voltage if it's within normal range
IE 002 Grid Lost Fult
• Or ask the installer for help.
Internal Code Internal Code Power grid voltage overrun
• Wait a moment, if the utility returns to normal, the system will reconnect.
> Inverter code > BMS code IE 003 Grid Volt Fault • Please check if the grid voltage is within normal range.
01 00 01 xx • Or ask the installer for help.

Electricity frequency beyond range


IE 004 Grid Freq Fault • If the utility returns to normal, the system reconnects.
Internal Code Internal Code • Or ask the installer for help.

> BAT-M > BAT-S1 PV voltage out of range


2.01 1.01 50 IE 005 PV Volt Fault • Check the output voltage of the PV panel
• Or ask the installer for help.
• press the “ESC" key to restart the inverter.
IE 006 Bus Volt Fault • Check that the PV input open circuit voltage is in the normal range.
Internal Code Internal Code
> BAT-S2
1.01 50
... > BAT-S8
1.01 50 IE 007 Bat Volt Fault
• Or ask the installer for help.
Battery voltage fault
• Check battery input voltage if it's within normal range
• Or ask the installer for help.
• The grid voltage was out of range in the last 10 minutes.
IE 008 AC10M Volt Fault • The system will return to normal if the grid returns to normal.
• Or ask the installer for help.

104 105
Troubleshooting Troubleshooting

Number Number
DCI overcurrent protection fault.
ARM software version mismatch Fault
IE 009 DCI OCP Fault • Wait for a while to check if it's back to normal.
IE 022 ARM Unmatched • update the software and press the ESC" key to restart the inverter.
• Or ask the installer for help.
• Or ask for help from the installer if itcan not return to normal .
DCV EPS overvoltage protection failure.
IE 010 DCV OVP Fault • Wait for a while to check if it's back to normal.
• Or ask the installer for help. Other device Fault
IE 023 Other Device Fault • update the software and press the ESC" key to restart the inverter.
Software Detection of Overcurrent Fault. • Or ask for help from the installer if itcan not return to normal .
• Wait for a while to check if it's back to normal.
IE 011 SW OCP Fault Mgr InterCom Fault
• Shut down photovoltaic, battery and grid connections
IE 025 InterComms Error • Shut down photovoltaic, battery and grid, reconnect.
• Or ask the installer for help.
• Or ask for help from the installer if itcan not return to normal .
Overcurrent protection fault.
• Check the impedance of DC input and AC output. • Internal communication errors
IE 012 RC OCP Fault • Wait for a while to check if it's back to normal.
IE 025 InterComms Error • Shut down photovoltaic, battery and grid connections.
• Or ask the installer for help. • Or ask for help from the installer if itcan not return to normal.
Insulation Fault
IE 013 Isolation Fault • Please check the wire insulation for damage.
Inverter EEPROM Fault.
• Wait for a while to check if it’s back to normal. • Shut down photovoltaic, battery and grid, reconnect.
• Or ask the installer for help. IE 026 Inv EEPROM Fault
• Or ask for help from the installer if it can not return to normal.
Temperature beyond limit
IE 014 Temp Over Fault • Check if ambient temperature exceeds the limit. Fault of Residual Current Device
• Or ask the installer for help. • Check the impedance of DC input and AC output.
IE 027 RCD Fault • Disconnect PV + PV - and batteries, reconnect.
EPSmode current is too strong. • Or ask for help from the installer if itcan not return to normal.
• Ensure that the load power is within the EPSpower range.
IE 015 Bat Con Dir Fault • Check for any non-linear load connections on the EPS. Electrical relay failure
• Move this load to check for recovery. IE 028 Grid Relay Fault • Disconnect PV+ PV- grid and batteries and reconnect.
• Or ask for help from the installer if itcan not return to normal. • Or ask for help from the installer if itcan not return to normal.

EPS over load fault.


• Shutdown the high-power device and press the “ESC" key to EPSrelay failure
IE 016 EPS Overload Fault IE 029 EPS Relay Fault • Disconnect PV+ ,PV-, grid and batteries and reconnect.
restart the inverter.
•Or ask for help from the installer if it can not return to normal. • Or ask for help from the installer if itcan not return to normal.

On-grid mode overload PVdirectionfault


• Shutdownthehigh-power device and press the" ESC" key to IE 030 PV ConnDirFault • Check if the PV input lines are connected in the opposite direction.
IE 017 OverLoad Fault restart the inverter. • Or ask for help from the installer if itcannotreturntonormal.
•Or ask for help from the installer if it can not return to normal.
Charge relay fault
•Close the high-power device and press the "ESC" key to restart the
IE 031 ChargerRelayFault • Press the ESC" key to restart the inverter. .
inverter.
IE 018 BatPowerLow • Or ask for help from the installer if itcannotreturntonormal.
•Please charge the battery to a level higher than the protection
capacity or protection voltage
EPS earth relay fault
Battery communication loss IE 032 EarthRaleyFault • Press the ESC" key to restart the inverter. .
• Check that the communication lines between the battery and • Or ask for help from the installer if itcannotreturntonormal.
IE 019 BMS Lost the inverter are properly connected.
• Or ask for help from the installer if it can not return to normal. Power type fault
IE 101 PowerTypeFault • Upgrade the software and press the ESC" key to restart the inverter.
Fan Fault • Or ask for help from the installer if itcannotreturntonormal.
• Check for any foreign matter that may have caused the fan not to
IE 020 Fan Fault function properly. EPS port over current fault
• Or ask for help from the installer if it can not return to normal. • Check that the EPS load does not exceed the system requirements,
IE 102 Port OC Warning and press the ESC" key to restart the inverter. .
Low temperature fault. • Or ask for help from the installer if itcannotreturntonormal.
IE 021 Low Temp • Check if the ambient temperature is too low.
• Or ask for help from the installer if it can not return to normal.

106 107
Troubleshooting Troubleshooting

Number Number

Manager EEEPROM Fault. Battery Unbalanced Failure


BE 009 BMS_CellImblance • Please contact the battery supplier.
.• Shut down photovoltaic ,battery and grid ,reconnect.
IE 103 Mgr EEPROM Fault
• Or seek help from the installer if it can not return to normal.
Battery hardware protection failure
BE 010 BMS_Hardware Protect • Please contact the battery supplier.
DSP version error.
IE 104 DSPunmatched • Check that the DSP1 version matches Battery circuit failure
• Or seek help from the installer if it can not return to normal. BE 011 BMS_Circuit_Fault • Restart the battery .
• Please contact the battery supplier.
NTC invalid
• Make sure the NTC is properly connected and the NTC is in good Battery insulation failure
IE 105 NTC Sample Invalid condition. BE 012 BMS_ISO_Fault • Check that the battery is properly grounded and restart the battery.
• Please confirm that the installation environment is normal • Please contact the battery supplier.
• Or ask for help from the installer, if itcannotreturnto normal.
Battery voltage sensor fault
Batterytemplow BE 013 BMS_VolSen_Fault • Please contact the battery supplier.
• Check the battery installation environment to ensure good heat
IE 106 Bat Temp Low dissipation. Temperature sensor failure
• Or ask for help from the installer, if itcannotreturnto normal. BE 014 BMS_TemppSen_Fault • Restart the battery .
• Please contact the battery supplier.
Batterytemphigh
• Check the battery installation environment to ensure good heat Battery current sensor fault
IE 107 Bat Temp High dissipation. BE 015 BMS_CurSensor Fault • Please contact the battery supplier.
• Or ask for help from the installer, if itcannotreturnto normal.
Battery relay failure
Meter error BE 016 BMS_Relay Fault • Please contact the battery supplier.
IE 109 Meter Fault •Please check that the instrument is working properly
• Or seek help from the installer if it can not return to normal. Battery type failure
BE 017 BMS_Type_Unmatch • Upgrade the battery BMS software.
Bypass relay fault • Please contact the battery supplier.
IE 110 BypassRaleyFault • Press the ESC" key to restart the inverter. .
• Or ask for help from the installer if itcannotreturntonormal. Battery version mismatch failure
BE 018 BMS_Ver_ Unmatch • Upgrade the battery BMS software.
Battery Error - External Communication Fault • Please contact the battery supplier.
BE 001 BMS_External_Err • Please contact the battery supplier.
Batterymanufacturer did not match the fault
BE 019 BMS_MFR_ Unmatch • Upgrade the battery BMS software.
Battery Error - Internal Communication Fault • Please contact the battery supplier.
BE 002 BMS_Internal_Err • Please contact the battery supplier.
Battery hardware and software mismatch failure
Over voltage in battery system BE 020 BMS_SW_ Unmatch • Upgrade the battery BMS software.
BE 003 BMS_OverVoltage • Please contact the battery supplier. • Please contact the battery supplier.

Low voltage in battery system Battery master slave control mismatches


BE 004 BMS_LowerVoltage • Please contact the battery supplier. BE 021 BMS_M&S_ Unmatch • Upgrade the battery BMS software.
• Please contact the battery supplier.
Battery fault - over charge fault
BE 005 BMS_ChargeOCP Battery charging request does not respond to a fault
• Please contact the battery supplier.
BE 022 BMS_CR_ NORespond • Upgrade the battery BMS software.
• Please contact the battery supplier.
Battery fault-discharge over current fault
BE 006 BMS_DischargeOCP • Please contact the battery supplier. Battery slave software protection failure
BE 023 BMS_SW_ Protect • Upgrade the battery BMS software.
Over temperature in battery system • Please contact the battery supplier.
BE 007 BMS_TemHigh • Please contact the battery supplier.
Battery fault-discharge over current fault
BE 024 BMS_536_Fault • Please contact the battery supplier.
Battery temperature sensor malfunction
BE 008 BMS_TempSensor Fault • Please contact the battery supplier.
Over temperature in battery system
BE 025 BMS_SelfcheckErr • Please contact the battery supplier.

108 109
Troubleshooting Troubleshooting

Number 8.2 Routine Maintenance


Battery temperature sensor malfunction
BE 026 BMS_TempdiffErr • Please contact the battery supplier.
Inverter do not require any maintenance or correction in most cases, but
if the inverter often loses power due to overheating, this can be
Battery Unbalanced Failure attributed to the following reason:
BE 027 BMS_BreakFault • Please contact the battery supplier.

Battery hardware protection failure


heat sink behind the inverter is covered with dirt.
BE 028 BMS_Flash_Fault • Please contact the battery supplier. If necessary, clean the cooling heat sink with a soft dry cloth or brush.
Only trained and authorized professionals familiar with safety
Battery precharge failure
BE 029 BMS_Precharge_Fault • Please contact the battery supplier. requirements can perform maintenance and maintenance work.

Battery air switch failure


BE 030 BMS_AirSwitch_Fault • Check that the battery breaker is off.
• Please contact the battery supplier. Ø Safety inspections

If the information panel of your inverter does not show the fault light, check
the following list to ensure the current installation status, correct operation. Safety checks should be conducted at least every 12 months, please
contact the manufacturer to arrange for appropriate training, expertise,
------Is the inverter located in a clean, dry and well-ventilated place? and practical experience in performing these tests. (Please note that this
------Is the DC input circuit breaker open? action is not covered by warranty). These data should be recorded in the
------Is the specification and length of the cable adequate? device log. If the equipment is not running properly or any test fails, the
------Are the input and output connections and wiring in good condition? equipment must be repaired for details of safety inspections, refer to
------Is the configuration set correct for your particular installation? section 2 of this manual for safety instructions and europe commission
instructions.
Please contact SolaX customer service for further assistance. Please be prepared to describe
the details of your system installation and provide the inverter serial number.

Ø Regular maintenance

In the process of using frequency converter, the manager should check and
maintain the machine regularly. The specific operation is as follows.

1.check whether the heat sink is covered with dirt, clean the machine and
absorb dust if necessary. This work should be performed from time to time.

2.check whether the frequency converter indicator is normal, check whether


the frequency converter button is normal, check whether the frequency
converter display is normal. This inspection should be conducted at least
every 6 months.

3.check the input and output lines for damage or aging. This inspection
should be conducted at least every 6 months.

4.Cleaning and safety inspection of PV modules shouldbe carried out at least


once every 6 months.

110 111
Dismantling Disclaimer

9 Decommissioning 10 Disclaimer
The X3-Hybrid G4 series hybrid inverters are transported, used and
9.1 Disassemble the Inverter operated under limited condition, such as environmental, electrical etc.
SolaX shall not be liable to provide the service, technical support or
Remove DC input line and AC output line of inverter. compensation under conditions listed below, including but not limited
Wait for at least 5 minutes to power off. to:
Remove all cable connections from the inverter.
Remove inverter from finger support the bracket. Inverter is damaged or broken by force majeure (such as earthquake,
Remove the bracket if necessary. flooding, thunderstorm, lighting, fire hazard, volcanic eruption etc).
Inverter's warranty is expired and doesn't buy extended warranty.
Can't provide the inverter's SN, warranty card or invoice.
Inverter is damaged by man-made cause.Inverter is used or operated
against any items in local policy.
9.2 Packing
Inverter's installation, configuration, commissioning doesn't follow the
Load the inverter into the original package if possible. requirements mentioned in this manual.
Inverter is installed, refitted or operated in improper ways mentioned
in this manual without authority from SolaX.
If the original package can not be found, you can also use the
Inverter is installed, operated under improper environment or
following requirements of the carton packaging:
electrical condition mentioned in this manual without authority from
Bearing capacity of more than 30 kg.
SolaX.
Easy to carry.
Inverter is changed, updated or disassembled on hardware or
Can completely seal the cover.
software without authority from SolaX.
Obtain the communication protocol from other illegal channels.
Build monitoring, control system without authority from SolaX.
9.3 Storage and Transportation
Connect to other brands batteries without authority from SolaX.
Store the inverter in a dry, temperature -40°C~70°C environment. SolaX will keep right to explain all the contents in this user manual.
Pay attention to less than four machines on each stack board
during storage and transportation.

9.4 Waste Disposal