Leyenda
Leyenda
LABELS
a S Model m. ATTENTION! 10. air ---air heat exchanger
S Serial No. Never pass compressed air through the dryer when it is stopped. 12. PV fan pressure switch
S Low/High side refrigeration 14. QS main switch
circuit design pressure Always start the dryer 5 minutes before slowly opening the air
15. HP high pressure switch
S Max air pressure inlet valve. If the airflow is to bestopped only switch the dryer
S Max compressed air inlet off after closing the air inlet. 16. ST high temperature thermostat
S Min. ambient n. SETTING (hot gas valve) 17. low pressure manometer
Max ambient Evaporating pressure in 0_C, with precision manometer con- 18. compressor valve
S Power supply nected at evaporator outlet. 25. thermometer sensor pocket
Electrical diagram no.
S Oil o. ATTENTION: SCROLL three---phase compressors. 27. gas charge point
If the compressor is noisy and the pressure on the (LP) gauge 28. water pressostatic valve
S Min. circuit ampacity
does not decrease you should immediately invert two phases.
S Max protective device rating 29. high pressure tap
Please refer to the service manual for more details.
S Compressor 30. QF1 compressor motor automatic switch
S Fan 1 p. ATTENTION: Hot and moving parts enclosed, disconnect the
mains supply before removing this cover. 30a QF2 fan motor automatic switch
S Fan 2 31. KM2 fan motor contactor
S Max cooling water pressure q. ATTENTION
1 Fully drain the piping before connecting this unit to the exter- 32. KM1 compressor motor contactor
S Min. cooling water pressure
S Refrigerant nal water piping (cold water, make up water, ect.). 33. TC1 auxiliary transformer
S Weight 2 Fitting of a standard strainer is also strongly recommended 35. power cable inlet
on the inlet water piping.
b QUALITY CHECKED INSPECTOR N. 302 36. remote control cable entry point
r. WARNING:
37. control panel
c. See Chapter 2 Risk of electric shock can cause injury or death.
Disconnect all remote electric power supplies before servicing. 38. temperature sensor NTC
d. Air inlet
s. BSPP pipe threads 40. liquid separator
e. Air outlet
use supplied adapters T0. dew point temperature sensor
d1. Water inlet
FU1-- 2 transformer fuse TC1
e1. Water outlet
DRAWINGS FU3-- 4 auxiliary fuse 230V
f. ATTENTION: components under power. A. TIMED SOLENOID DRAIN FU5 control panel fuse
g. ATTENTION: SCHRADER VALVE 1. MC compressor PI compressor internal protection
1 This unit is equipped with refrigerant as for quantity and kind clearly shown 2. refrigerant condenser KA1 high pressure alarm relay
in operating manual and with identification label.
2 Any ordinary test and / or refrigerant recharge by means of connections can 3. EV-- 1-- 2 fan motor KA2 general alarm relay
take place only after refrigerant evacuation. The evacuation must be pro- 4. evaporator C1 compressor start capacitor
portional to dimensions and length of the connections used. The use of the 5. separator
valve can be justified only when the dryer is not in working order. C2 fan run capacitor
3 During the unit guarantee period, the Schrader valve can be used by autho- 6. insulation QF residual current circuit---breaker
rized staff only, otherwise any damage caused by a wrong refrigerant 7. expansion capillary (by installer)
recharge will not be under warranty. (A) remove bridge if “remote on---off”
8. refrigerant filter
l. Condensate drain connection is installed
9. hot gas valve