Accueil > Unclassified > Communication between a Siemens S7-1200 / 1500 and Movicon 11.5 PLC with the S7 TIA Symbolic driver

UNCLASSIFIED

COMMUNICATION BETWEEN A SIEMENS S7-1200 /

1500 AND MOVICON 11.5 PLC WITH THE S7 TIA


SYMBOLIC DRIVER
 Lab4Sys  22 March 2020  5312  0

L’attribut alt de cette image est vide, son nom de fichier est S7TIASymbolic-01.png.
S7 TIA Symbolic

The S7 TIA symbolic driver has been specially designed to access SIMATIC S7-1200 and S7-1500 controllers

with symbolic addressing and access to optimized data blocks.

This driver needs the ACCON-AGLink software library (from DELTA LOGIC Automatisierungstechnik GmbH) to

communicate with the server equipment.

https://lab4sys.com/en/communication-between-a-siemens-s7-1200-1500-and-movicon-11-5-plc-with-the-s7-tia-symbolic-driver/?cn-reloaded=1 1/5
9/23/22, 10:33 PM Communication between a S7-1200 / 1500 and Movicon 11.5 PLC

The file for this library is called “AGLink40.DLL”. From Movicon version “11.4.1.12”, the driver requires version
“5.3.1.0” or higher of the DELTA LOGIC library.

The first step in using this driver is to import the information on the variables of a “TIA_Portal” project or

directly from the PLC.

For more details on this operation, refer to the section Importing variables, see the different articles below:

The requirements
PLCs that can communicate

Siemens S7-1200 and Siemens S7-1500 PLCs

Supported protocol

S7-TCP/IP TIA.

Driver limits

A maximum of 256 stations can be defined.

Hardware and software used to test the driver

The driver has been tested with ACCON-AGLink library (AGLink40.DLL) version 5.3.1.0 and a Siemens S7 1200

PLC, CPU 1212C version FW 4.1 supplied with an Ethernet port.

Driver installation

A basic communication test has been implemented for this driver to verify if the cables have been properly

connected and if the primary communication parameter has been set correctly. For details, see the test /

comm cable user manual.

For this pilot, the communication test was performed by reading the MLFB number of the PLC.

Communication cable

The cable should be a standard Ethernet cable, used in any LAN network.

Two different versions can be chosen, depending on the type of connection.

A “Straight Through” cable, for a Hub connection, or a “Crossover” cable, for a peer-to-peer connection.

It may interest you


Telemecanic programmable logic controllers
Best site for healthy recipes, cooking and beauty for women
Download Vijeo Citect Version 7.5 software
Download proteus software version 8
Download the student version of the EPLAN Electric software

     
Share Tweet Share Share Share Mail

 Previous Article Next Article 

industrial laptop 3D vision sensors for palletizing and depalletizing

https://lab4sys.com/en/communication-between-a-siemens-s7-1200-1500-and-movicon-11-5-plc-with-the-s7-tia-symbolic-driver/?cn-reloaded=1 2/5
9/23/22, 10:33 PM Communication between a S7-1200 / 1500 and Movicon 11.5 PLC

LAB4SYS

LEAVE A REPLY

Your email address will not be published. Required fields are marked *

Name *

Email *

Website

Solve : *

9 × 21 =

Comment *

Post Comment

ARTICLES SIMILAIRES

UNCLASSIFIED
UNCLASSIFIED
SoMachine schneider electric FULL IP65 and FULL INOX industrial screens
 Lab4Sys  7 March 2020  Lab4Sys  14 March 2020
UNCLASSIFIED

Software configuration of ARDUINO hardware


 Lab4Sys  18 April 2019

Search

https://lab4sys.com/en/communication-between-a-siemens-s7-1200-1500-and-movicon-11-5-plc-with-the-s7-tia-symbolic-driver/?cn-reloaded=1 3/5
9/23/22, 10:33 PM Communication between a S7-1200 / 1500 and Movicon 11.5 PLC

OMOUMA.NET

It may interest you

Popular Posts

Best site for healthy recipes, cooking and beauty for women
 Lab4Sys  10 September 2021

What is a PC?
 Lab4Sys  27 January 2021

https://lab4sys.com/en/communication-between-a-siemens-s7-1200-1500-and-movicon-11-5-plc-with-the-s7-tia-symbolic-driver/?cn-reloaded=1 4/5
9/23/22, 10:33 PM Communication between a S7-1200 / 1500 and Movicon 11.5 PLC
What is Industry 4.0? Super easy explanation for everyone
 Lab4Sys  2 July 2020

Stay connected

Latest Article

 Telemecanic programmable logic controllers


 Best site for healthy recipes, cooking and beauty for women
 Download Vijeo Citect Version 7.5 software
 Download proteus software version 8
 Download the student version of the EPLAN Electric software
 Download SUCOSOFT S40 V5.0 software

2020 Lab4Sys
Who are we privacy policy Contact us Download Make a donation

https://lab4sys.com/en/communication-between-a-siemens-s7-1200-1500-and-movicon-11-5-plc-with-the-s7-tia-symbolic-driver/?cn-reloaded=1 5/5

You might also like