Nuclear Line Card FINAL

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Equipment

Bag In/Bag Out (BIBO) Walk-in Filter House


The AAF Bag In/Bag Out side access filter system is a For systems up to 30,000 CFM.
safe, simple, reliable method for removing contaminated AAF International®, a world leader in clean air
particulate filters and/or gases in hazardous solutions, was there with the right products when
environments. All housings are built and tested per the nuclear industry first began – and continues to
ASME N509 and ASME AG-1 Section HA. provide products to help you meet the continuing
demand for qualified and dependable solutions to
With this system, maintenance personnel are protected
support operating license renewals, power
from direct contact with the interior of the housing and
uprates and new construction.
hazardous contaminants during filter change-out.

• Bag In/Bag Out • Retrofit HVAC Solutions


• Walk-In Housings • Chillers
• Side Access TSC • Replacement Parts
• Cooling Coils • Filter Media
Nuclear Cooling Coils • HEPA Filters • Electric and
AAF’s nuclear coils are custom designed to meet any • Carbon Filters Steam Heaters
application. Built and tested to ASME “N” • Commercial Grade
• ASHRAE Filters
stamp requirements. Dedication
• Fans/Dampers
• Air Handling Units

Side Access TSC


Designed for smaller systems and confined spaces.
The AAF TSC housing is in use in over 90% of the
nuclear power plants in the US today.

NUCLEAR
BETTER AIR IS OUR BUSINESS® E N V I R O N M E N TA L
SYSTEMS
Filtration
Adsorber Filters HEPA Filters ASHRAE Filters
Type II | Designed, manufactured AAF VariCel®
Reuseable Type and tested under a For nuclear use. Up to 90-95%
304 trays. Meets Nuclear Quality ASHRAE 52.1 efficiency.
the requirements Assurance Program, UL 900, ASHRAE 52.2
of ASME AG-1 Section FD and N509. Filled with meeting all requirements MERV 11-14.
impregnated carbon that adsorb radioactive Iodides and of ASME NQA-1 | Available in Type 304 or 409
other gases. Each Type II tray is rated for 333 CFM. Section FC and Stainless Steel Cell Sides.
10CFR50 App. B.
Type III | Meets the requirements of
| Meets the requirements
A flexible system in which the carbon ASME AG-1 Section FB.
of ASME N509. Stainless Steel Casing
can be replaced without removing
Qualified to ASME AG-1
the tray or filter. Suitable for systems VariCel® V
Section FC (Formerly
2,000-30,000 CFM. Meets the High capacity, extended surface
MIL-F-51068) and to
requirements of ASME mini-pleat filters. Efficiencies of
UL 586. Capacity of up
AG-1 Section FE. 70, 80 and 95% are available.
to 1500 CFM in a variety
UL 900, ASHRAE 52.2
Type IV of sizes.
MERV 12-15.
This carbon filter is
| Neoprene gasket or
a BIBO type rated VariCel® II
gel seals.
for 1,000-1,250 Extended surface mini-pleat
CFM. Meets the | Available in Type 304 slim line design. Available up
requirements of ASME AG-1 Section FH. or 409 Stainless Steel to 95% efficiencies. UL 900,
Cell Sides. ASHRAE 52.2 MERV 11-15.
Fire-Retardant Plywood Casing

Adsorbent Test Canisters


Used to determine remaining operating
life in a given bed of adsorbent. Since it
is not practical to take samples from an
adsorbent bed, small canisters are piped
up in parallel to the main beds to pass a proportional
amount of air flow. Canisters are periodically removed AAF has a policy of continuous product research and
from the system for analysis of remaining life. improvement and reserves the right to change design
and specifications without notice.

ISO Certified Firm ©2014 AAF International


NES-1-705D 06/14 NQA-1
9920 Corporate Campus Drive, Suite 2200, Louisville, KY 40223-5690 10 CFR 50 App. B
1.800.477.1214 nuclear@aafintl.com | www.aafintl.com 10 CFR Part 21

You might also like