Professional Documents
Culture Documents
12-Schneider Electric StruxureWare DCIM Optimization Tools v4 Belgrade 2017
12-Schneider Electric StruxureWare DCIM Optimization Tools v4 Belgrade 2017
Confidential | Page 1
•Software consultants
•Software developer team
•Software implementation & integration experts
•Our objective:
•Helping you to improve your data centre operations and lower costs through
digital transformation
Professional Services
Confidential | Page 2
Key Operational challenges
Source: Uptime Institute global survey 2017 of 1000 data centre operators
Confidential | Page 3
Confidential | Page 4
Schneider Electric online survey to establish your current DCIM maturity level
Confidential | Page 5
6
Data Center Energy Consumption
Confidential | Page 7
Objective
Cooling Optimize
•Reduce the power consumption cooling system
How?
•DCO base software +
•Cooling Optimize (HW + SW + Services)
Customer Benefit
•40% saving in cooling cost
IT Optimize & IT Power Control
Intel Data Center Manager
10
Intel Confidential | Q1 2015 | Information and plans subject to change without notice.
Copyright © 2015 , Intel Corporation. All rights reserved.
Intel® DCM
A middleware technology with web service APIs for data center power and
thermal management – easy to integrate in the Management Console
ISV
ISV Management
Management Console
Console
Energy Director Middleware (Web Service API)
MONITOR
MONITOR CONTROL
CONTROL TREND
TREND
SCALABILITY
SCALABILITY STANDARDS
STANDARDS
Hardware Protocols
Node
NodeManager
Manager iDRAC
iDRAC iLO/DCMI
iLO/DCMI IMM
IMM CMC
CMC OA
OA IMM
IMM SNMP
SNMP
IPMI
IPMI IPMI
IPMI IPMI
IPMI IPMI
IPMI HTTPS/WS-MAN
HTTPS/WS-MAN SSH/CLI
SSH/CLI SSH/CLI
SSH/CLI
Rack
Rack Servers
Servers Blade
Blade Servers
Servers PDU
PDU and
and UPS
UPS
IT Optimize
Server Level Asset Utilisation
12
The Nameplate Challenge
What is nameplate?
• Worst case power draw across the entire
IT system family
• Not considering the actual configuration of
Nameplate
the server
• Typically linked to the capabilities of the
Power Draw
server’s power supply Real max
Actual power draw
Confidential | Page 13
The Standard Performance Evaluation Dell PowerEdge R720
Corporation (SPEC) is a non‐profit Intel Xeon E5‐2670, 2.6 GHz
corporation formed to establish, maintain 16 cores, 2 chips, 8
and endorse a standardized set of relevant cores/chip
benchmarks that can be applied to the 6 x 4096 MB
newest generation of high‐performance 1 x 100GB SATA SSD
computers. 496W PSU
Confidential | Page 14
IT Optimize > Auto Discovery Process
Setup network range Run discovery on Map discovery result
and protocols traditional network to DC model
Confidential | Page 15
Confidential | Page 16
IT Optimize > user friendly interface
Confidential | Page 17
Confidential | Page 18
“Capacity costs money,” Riccardo said. “The
most efficient data center is the one you don’t
have to build. At Sky, we want to be able to
measure what capacity we have as a resource,
and understand how long it will be before we
need additional infrastructure. We want to know
which of our servers are working efficiently and
which ones are not and therefore are candidates
for decommissioning or further virtualisation. In a
sense, power usage effectiveness (PUE) is not
that useful to us – our key metrics are CPU-
utilisation and power consumption.”
IT Power Control
Rack Level Power Capping Policy
20
Introducing Power Capping
- The capability to limit the power consumption of a server, to some threshold that is less
than or equal to the system’s maximum rated power
Confidential | Page 21
Confidential | Page 22
Download the whitepaper at intel.com
Power Capping ROI
Energy cost calculation based on a 4kW IT load rack
Confidential | Page 23
Cooling Optimize
Dynamic Self Learning Cooling Control System
24
Cooling Optimize
Partnership
Confidential | Page 25
Cooling Optimize
Typical Facility
Design
Airflow is zoned
Confidential | Page 26
Cooling Optimize
Typical Facility
Confidential | Page 27
Traditional approaches to
cooling leave money on the
table.
Confidential | Page 28
Cooling Optimize
Confidential | Page 29
Cooling Optimize
Hot Spots
Excessive airflow causes turbulence and
hot spots
Short Cycling
Low return air temperatures reduce
efficiency, stability and capacity
Confidential | Page 30
Cooling Optimize
Typical Control
Confidential | Page 31
Cooling Optimize
Cooling Optimize
*Results from an actual Cooling Optimize technology deployment.
Confidential | Page 32
Cooling Optimize
Confidential | Page 33
Cooling Optimize
Cooling Optimize
*Results from an actual Cooling Optimize technology deployment.
Confidential | Page 34
Cooling Optimize
Confidential | Page 35
Cooling Optimize
Architecture
Rack Sensors
Collect temperature
every 3 to 4 racks StruxureWare for DC:
Gateways AI Engine Data Center Operation
Manage wireless Analyzes data. Issues Provides operational insight.
communication control commands. Allows for system configuration.
Confidential | Page 37
Cooling Optimize
Confidential | Page 38
Cooling Energy Savings
Benefits/ROI can be Estimated with Basic Site Data
Cooling Optimize
Example Report
¾ Provides clear energy savings reporting vs.
original baseline operating conditions
Confidential | Page 40
Cooling Optimize
Additional Benefits
Operational benefits as well as energy savings
9 Improved thermal management
Temperatures will be directly and automatically managed to preset limits, delivering increased reliability.
Confidential | Page 41
Physical space
Mobile Security
• Tenant Portal
Capacity Management Dynamic Cooling • Multi Tenant Information
Control • Key KPIs
Change Management IT Asset • Mobile Reporting 42
Confidential Property of Schneider Electric Asset Management
Utilisation • Billing
Call to action
Professional services provided by Data Center Software Solutions
Releases potential
for energy savings
Confidential | Page 43
Thank you
matthew.farnell@schneider-electric.com
uk.linkedin.com/in/matthewfarnell
44
Make the most of your energy SM
45