1 Tag Number 85- 000-FI -607

2 Service Desalt. Water Distribution


General 3 P.I.D. No. Pipe Class X-85-D-0-1000-41
Data 4 Line Size Line Number 2 In 85--000-600-UW-2"-AH001-N
5 Line Material FIBERGLASS
6 Sour Service Special Conditions
7 PED SIL
8 Fluid Phase State Water Water Single Phase
9 Fluid Quality Flowing
10 Flow Min. Flow Norm. Flow Max. Units 0 7.5 m³/h @Cond
Process
11 Pressure Norm. Temperature Norm. 4 bar-g 28 ºC
Conditions 12 Design Pressure Min Max. 9 bar-g
13 Design Temperature Min Max. 70 ºC
14 Density Min. Norm Max. Units 996.5 996.5 kg/m³
15 Molecular Mass Viscosity Norm. 0.832 cP
16 Type Local Indicator Rotameter
17 Flange Size Rating Facing 2" 150 lb ANSI RF
Range 18 From To Eng. Units 0 To 10 m3/h
19 Scale Graduation Direct scale
20 Body/ Flanges Material AISI 316 Stainless Steel
21 Connection Layout Top - Bottom
22 Calibration Tube Mat. Stainless Steel
23 Float / Extention Mat. 316L Stainless Steel
24 Indicator . Round Type
Rotameter
Details 25 Output Signal Load
26 Pneum.Output Signal
27 Elec. Conn. Pneum. Conn.
28 Cable Gland
29 Area Classification
30 Electrical Protection Class
31 Accuracy 1%
32 mA Meter mA Meter Scale
33 Air Set Regulator
34 Steam Jacket
Accessories
35 Needle Valve
36 Pressure Regulator
37
38 Manufacturer YOKOGAWA
39 Model RAMC05-A1SS-72M5
Purchase
40 Client Reference Requisition No Item 1553.02
41 Serial No.
42 Material Code

Notes:

INSTRUMENT SPECIFICATION
Rotameter

C1 AK VS FM/PV 9/19/2005 ISSUED FOR ORDER


A1 AK VS FM/PV 4/18/2005 ISSUED FOR INQUIRY Sheet 2
No. By Chk Appr Date Revision Code: 107 Dwg. No.: X-85-S-I-1553.05 Rev.: C1