Water Chillers

CH 50 - CH 900 Series

English

The CH 50 – CH 900 series Water Chillers are amongst the most compact ones in the
market and guarantee maximum energy efficiency and application flexibility, with capacities
from 6.6 kW to 108 kW.

Customers. The core of our innovation


Wa t e r C h i l l e r s
CH 50 – CH 900 Series
The CH Series, a range of compact and energy efficient Water Chillers, with
cooling capacities from 6.6 to 108 kW (5,700 to 93,300 kcal/h) covers all
requirements and provides cooling water for all applications. Both R407C
“green refrigerant” and traditional R22 are available (the latter only where
allowed).

CH Series

Standard features
> Scroll compressors
> R407C refrigerant
> Polyester painted galvanised frame
> High and low pressure switches
> High and low pressure gauges
> Thermostatic expansion valve
> Finned copper tube condenser
> Washable metal filters to protect the air-cooled condensers
> Brazed plate type evaporator (CH 50 - CH 480)
> Shell and tube evaporator (CH 700 - CH 900)
> Castors (CH 50 and CH 90 only)
> Antifreeze temperature switch
> Internal hot-deep galvanised water tanks
> High performance stainless steel water pumps
> Water pressure safety switch CH 380 - CH 480
> Water by-pass valve
> Microprocessor control
> Alarm output and remote control facility
> Automatic fill, backup and air relief kit
Wa t e r C h i l l e r s C H 5 0 - C H 9 0 0 S e r i e s

The CH chillers are ideal for cooling moulds, hydraulic oil of injection and
blow moulding machines, extruders, thermoforming machines, moulds,
calanders and rolls, etc. They are also suitable for use with machine tools
and for many other applications where accurate cooling is required. The
CH chillers are reliable and versatile, easy to install and ready for use.

CH 50 - CH 90

All units have built-in water tanks and high performance circulating
pumps and can operate in ambient conditions up to 40°C (CH 50 -
CH 480) or up to 45°C (CH 700 and CH 900). Versions for temperature
up to 50°C are available on request. Start-up is possible at 40°C ambient
temperature.

CH 50 - CH 90: water tank

Performance and reliability


The CH Series is characterised by extremely compact dimensions. The Scroll compressors, used as standard
on all models, allow very low energy consumption. These compressors have low noise levels and eliminate the risk
of liquid refrigerant damaging the compressors.

CH 180 - CH 280 Condenser


fans
Safety at its best

The CH chiller Series boasts the following safety features:


> high and low pressure switches
> antifreeze sensor
> flow switch (CH 700 and CH 900) to protect against insufficient water flow
> differential pressure switch (CH 50 – CH 480) to protect against insufficient water flow
> high and low pressure gauges
> washable metal filters to protect the air-cooled condensers

CH 380 - CH 480 CH 380 - CH 480: internal view

The electronic microprocessor controller ensures accurate temperature control. The controller is user-friendly
and displays the set-point and the actual cooling water temperature, and all alarm conditions.

CH 50 - CH 480 control panel CH 700 - CH 900 control panel


Wa t e r C h i l l e r s C H 5 0 - C H 9 0 0 S e r i e s

Optional features

> Outdoor installation versions


> R22 refrigerant gas
> High pressure stainless steel pump
> Automatic glycol make-up system (ambient or water temperatures below 0°C)
> Automatic water by-pass valve
> Hot gas by-pass for extremely precise water temperature
> Mechanical water filter

CH 700 - CH 900: internal view

Simple to install
> Pre-set to operate
> Base frame for forklift handling
> Reduced weight and footprint dimensions
> Easy start-up with high water temperatures
> Possible air exhaust ducting for heat recovery

> All models can be installed outdoors:


- installation underneath a protective shed
(CH 50 – CH 480)
- installation with no protection (CH 700 and CH 900)
- condenser fans with automatic speed regulation device

Air ducting
Te c h n i c a l d a t a

-50
R407c
40
(R22) -80
60 50
CHFIC2 40 30
-60 30
R134a 40 30
20 20
20
C 10
-1
+30 0
0
C bar 10
+50 EN 2
12 837-1 10
10

C 4
10
+30
6 0
8 20
40
30 0
10
20
20

10

R407c-50
40
(R22) 60 50
CHFIC2-80 40 30
-60 30
R134a 40 30
20 20 20
C 10
-1
+30 0
0
C bar 10
+50 EN 2
12 837-1 10
10

C 4
10
+30
6 0
H
8 20
40
30 0
10
20
20

10
H

R407c-50
40
(R22) -80
60 50
CHFIC2 40 30
-60 30
R134a 40 30
20 20 20
C 10
-1
+30 0
0
C bar 10
+50 EN 2
12 837-1 10
10
C 4
10
+30
6 0
8 20
40
30 0
10
20
20

10

R407c-50
40
(R22) -80
60 50
CHFIC2 40 30
-60 30
R134a 40 30
20 20 20
C 10
+30 -1
0
0
C bar 10
+50 EN 2
12 837-1
10 10

C 4
10
+30
6 0
8 20
40
30 0
10
20
20

10

L
W
W
L

CH 50 - CH 280 CH 380 - CH 900


Single-fan models Dual-fan models

CHILLERS CH 50 CH 90 CH 180 CH 280


Cooling capacity kW 6.6 10.2 22.0 37.6
kcal/h 5,700 8,800 18,900 32,300
Nominal compressor absorbed power kW 1.3 2.2 4.2 8.0
Standard pump m3/h 1.2 / 4.8 1.2 / 4.8 1.2 / 4.8 3.6 / 6.0
bar 3.0 / 2.2 3.0 / 2.2 4.5 / 2.8 3.6 / 3.0
kW 0.55 Water 0.55 0.90 1.10
High pressure pump m3/h 1.2 / 8.4 1.2 / 8.4 1.2 / 8.4 1.2 / 12.0
bar 6.0 / 4.1 6.0 / 4.1 6.0 / 4.1 6.1 / 4.6
kW 1,85 1.85 1.85 3.00
Condenser fans m3/h 6,100 5,600 7,800 8,300
kW 0.61 0.61 0.72 0.72
Total installed power (standard pump) kW 3.3 4.4 8.8 14.5
Total installed power (high pressure pump) kW 5.1 6.2 10.1 17.3
Tank capacity dm3 70 70 100 100
Weight kg 230 240 295 370
Dimensions WxLxH mm 677x1007x1500 677x1007x1500 885x1220x1670 885x1220x1670

The data refer to the following conditions: R407C refrigerant; 15°C outlet water temperature; 25°C ambient air temperature; 400V/3/50Hz.
Water-condensed chillers are available on request.
Wa t e r C h i l l e r s C H 5 0 - C H 9 0 0 S e r i e s

CHILLERS CH 380 CH 480 CH 700 CH 900


Cooling capacity kW 47.4 57.0 88.8 108.5
kcal/h 40,800 49,000 76,400 93,300
Nominal compressor absorbed power kW 9.9 11.9 2 x 9.0 2 x 11.9
Standard pump m3/h 3.6 / 7.2 4.8 / 9.6 6.0 / 24.0 6.0 / 30.0
bar 4.6 / 3.7 4.0 / 3.3 4.3 / 2.4 5.2 / 2.6
kW 1.50 1.85 3.00 4,00
High pressure pump m3/h 1.2 / 12.0 1.2 / 12.0 15.0 / 48.0 15.0 / 48.0
bar 6.1 / 4.6 6.1 / 4.6 5.5 / 3.6 5.5 / 3.6
kW 3.00 3.00 7.50 7.50
Condenser fans m3/h 2 x 7,500 2 x 7,200 2 x 9,400 2 x 19,000
kW 2 x 0.82 2 x 0.82 2 x 0.72 2 x 1.45
Total installed power (standard pump) kW 18.8 22.7 31.8 43.8
Total installed power (high pressure pump) kW 21.1 24.5 36.3 47.3
Tank capacity dm3 150 150 300 300
Weight kg 460 500 990 1085
Dimensions WxLxH mm 886x1409x2010 886x1409x2010 1210x2225x2200 1210x2225x2200

The data refer to the following conditions: R407C refrigerant; 15°C outlet water temperature; 25°C ambient air temperature; 400V/3/50Hz.
Water-condensed chillers are available on request.
Cooling capacity kcal/h
Cooling capacity Kw

Cooling capacity kcal/h


Cooling capacity Kw

Ambient air Ambient air


temperature 25°C temperature 25°C
R407C - 50 Hz R407C - 50 Hz

Outlet water temperature °C Outlet water temperature °C


0506 - 9910675 - R1 - Modification Reserved - Piovan Spa
w w w. p i o v a n . c o m

EUROPE AMERICA ASIA

PIOVAN S.p.A. PIOVAN CANADA LTD. PIOVAN ASIA Pte Ltd


Tel. +39 041 57.99.111 Tel. +1 905 629.88.22 Tel. +65 6 87.45.930
Fax +39 041 48.74.37 Fax +1 905 629.88.27 Fax +65 6 87.45.901
sales@piovan.com info@piovancanada.com sales@piovan.com.sg

PIOVAN GmbH PIOVAN do BRASIL


Tel. +49 89 32.94.57.0 Tel. +55 11 3693.9500
Fax +49 89 32.94.57.11 Fax +55 11 3693.9515
info@piovan.de piovan@piovan.com.br

You might also like