Flow diagram
Air dryer
Reference Name
AI Air inlet
AO Air outlet
1 Air/air heat exchanger
2 Air/refrigerant heat exchanger/evaporator
3 Condensate separator
4 Condensate outlet
5 Refrigerant compressor
2920 1634 04 23
Instruction book
Reference Name
6 Refrigerant condenser
7 Liquid refrigerant dryer/filter
8 Thermostatic expansion valve
9 Hot gas by-pass valve
10 Condenser cooling fan
11 Pressure switch, fan control
Refrigerant circuit
Compressor (5) delivers hot, high-pressure refrigerant gas which flows through condenser (6) where most of
the refrigerant condenses.
The liquid flows through liquid refrigerant dryer/filter (7) to capillary tube (8). The refrigerant leaves the
capillary tube at evaporating pressure.
The refrigerant enters evaporator (2) where it withdraws heat from the compressed air by further evaporation
at constant pressure. The heated refrigerant leaves the evaporator and is sucked in by the compressor (5).
By-pass valve (9) regulates the refrigerant flow. Fan (10) is switched on or off by switch (11) depending on
the loading degree of the refrigerant circuit.
24 2920 1634 04
Instruction book
3 Elektronikon II regulator
Control panel
General
The Elektronikon regulator controls the compressor:
• By matching the compressor output to the air consumption
• By stopping the compressor whenever necessary
• By restarting the compressor when required
In general, the Elektronikon regulator has following functions:
• Controlling the compressor
• Protecting the compressor
• Monitoring components subject to service
• Automatic restart after voltage failure (made inactive)
2920 1634 04 25
Instruction book
Shut-down warning
A shut-down warning level is a programmable level below the shut-down level.
If the compressor element outlet temperature exceeds the programmed shut-down warning level, a message
will appear on display (1) and general alarm LED (2) will light up to warn the operator that the shut-down
warning level is exceeded.
The message disappears as soon as the warning condition disappears.
Service warning
A number of service operations are grouped (called Service plans A, B, C, ...). Each Service plan has a
programmed time interval. If a time interval is exceeded, a message will appear on display (1) to warn the
operator to carry out the service actions belonging to that plan.
Warning
A warning message also appears if:
• On water-cooled compressors, the cooling water outlet temperature exceeds the warning level.
• On Full-Feature compressors, the dewpoint temperature exceeds the warning level.
If activated, and provided the regulator was in the automatic operation mode, the
compressor will automatically restart if the supply voltage to the module is restored within
a programmed time period.
The power recovery time (the period within which the voltage must be restored to have an
automatic restart) can be set between 10 and 3600 seconds or to ‘Infinite’. If the power
recovery time is set to ‘Infinite’, the compressor will always restart after a voltage failure,
no matter how long it takes to restore the voltage. A restart delay can also be programmed,
allowing e.g. two compressors to be restarted one after the other.
26 2920 1634 04
Instruction book
Elektronikon regulator