Professional Documents
Culture Documents
#009 Hotwork-Welding On Pump Room - 01-03-10
#009 Hotwork-Welding On Pump Room - 01-03-10
TYPE OF ACTIVITY: ROUTINE / NON- DESCRIPTION OF ACTIVITY : HOT WORK (ELECTRIC ARC WELDING ) - PUMP ROOM
ROUTINE
RISK ASSESSMENT GUIDE : RISK MUST BE REDUCED TO AS LOW AS REASONABLY PRACTICABLE (ALARP)
STEP 1 : CONSIDER SEVERITY OF HARM (S) STEP 2 : CONSIDER LIKELIHOOD (L) STEP 3:CALCULATE RISK
1: NEGLIGIBLE: Near Miss or Simple First Aid/ Simple Repairs by ship staff/ Spill within spill trays 1: IMPROBABLE-Event not expected to occur RISK RATING RR = S x L
2: MINOR : Injury require Medical Treatment; MTC/ Repair need external assistance / Spill on deck < 1 m3 2 : RARE: Expected to occur in exceptional situations RR RISK CATEGORY
MODERATE: Serious injury or multiple minor injuries; LTI / Repairs affecting seaworthiness of ship leading to CoC / Spill on
3: 3: POSSIBLE: May occur at some time / occurred in the past
deck > 1 m3 1- 5 L - LOW
CRITICAL : Single fatality, Serious injuries, permanent disability / Requires lay up repairs or extensive drydockings, 3rd
4: 4: LIKELY : Possibility of occurrence of isolated incidents
party claims/ Spill overboard < 100L 6 - 10 M - MEDIUM
CATASTROPHIC : Mutiple Fatalaities or Long Term disabilities/ Total Loss of ship or immediate layup/dry-docking for major
5: 5: CERTAIN: Is expected to occur in most situations
repairs / Major overboard spill > 100 L 11 - 25 H - HIGH
NO HAZARD DESCRIPTION RISK EXISTING CONTROLS RISK RATING RISK ADDITIONAL CONTROLS RESIDUAL RISK RESI-
(WITH CONTROLS IN CATEG (IF NOT REQUIRED, WRITE "N". RATING DUAL
PLACE)
L/M/H IF REQUIRED, LIST OUT THE ADDITIONAL (WITH ADDIT'L RISK
CONTROLS ) CONTROLS)
CAT.
( S x L= RR) (S x L = RR) L/M/H
S L RR S L RR
1. Presence of toxic and combustible 1. Breathing 1. Work team to be inside the pump room only after 4 2 8 M 1. All personnel should evacuate 4 1 4 L
gases, and oxygen deficiency in the difficulty, the Risk Assessment for Enclosed Space entry is the PR if there is a problem with
pump room unconsciousness, completed, control measures for the same in place ventilation.
fatalities and "Enclosed Space Entry Permit" is issued.
2. Continuously and thoroughly ventilate the space 2. Provide adequate breaktime for
prior to entry and thereafter thoughout the period it is prolonged work
occupied
3. Periodic atmospheric checks for oxygen, toxic 3. Regularly check for any leakages
gaes and hydrocarbons to be carried out as the work in pipes or valves inside the
progresses pumproom
4. Maintain effective communication methods 4. Raise alarm and arrange for
between personnel within the pumproom and those emergency rescue if there is no
outside. Make communication checks at pre-agreed response from pumproom during
intervals. communication checks
6. Damage caused to the deck fitting 1. Property 1. Welding area, including machinery around 1.5 1 2 2 L N
machinery close to the work site due to damage sqm to be completely covered by welding sheet.
hot welding sparks
7. Metal slips, slag particles flying around 1. Eye injuries 1. Ensure the use of PPE like face shield or welding 2 2 4 L N
screens during chipping and cleaning of work piece
8. Ultra vilotet and harmful light and 1. Eye injuries 1. Ensure the use of PPE like welding goggles and 2 2 4 L N
radiation given off during welding face shield or welding screens
9. Contact of Filler Rod / Tungston Rod 1. Burns 1. Ensure the use of PPE like long sleeved 2 2 4 L N
with body parts, Exposure to heat, coveralls, aprons, leather gloves, helmets, safety
Sparks contacting body shoes etc.
10. Insulation failure of welding generator 1. Electrocution 1. The earthing connection shall be adjacent to the 4 2 8 M 1. Only competent persons shall be 4 1 4 L
work site and the earth return cable shall lead allowed to set and use the welding
directly back to the welding machine. Do not use the equipment. Post clear instructions
ship's structure as the earth return. for the usage of welding equipment
at work site
11. Damage of welding cables by 1. Electrocution 1. Ensure the welding cables of good quality and 3 1 3 L N
overheating double insulated. Welding cables should not be
placed under heavy objects. Ensure that welding
cables are conncetd by using proper connectors
12. Welding Operator's body contact with 1. Electrocution 1. Ensure the welding opertor is wearing non- 3 2 6 M 3 1 3 L
electricity by any means conducting safety footwear in addition to the PPE. 1. An assistant should be in
Clothing and gloves should be dry. continuous attendance who should
be ready to cut off power instantly,
raise the alarm and apply artificial
respiration without delay.
Final Asesssment : Provided no deviations from the recommended control measures, the residual risk assessed is As Low As Resonably Practicable (ALARP).
Supplementary measures include correct use of PPE & Tool Box talks that ensure all workers are fully aware of the control measures.
Residual risk - HIGH : If RR is "High" category, written instructions for conducting the job and approval shall be obtained from the shore office to commence the operation.
Residual risk - MEDIUM: If RR is "Medium" , a constant monitoring of events shall be maintained and ensure all identified preventative and mitigating measures are always in place.
PREPARED BY: TECH. DEPT , S & Q DEPT. APPROVED BY: S & Q MANAGER
01 03 2010