22 VVX Series 82 Wireless Remote Controllers
TR 0.50 0.63 0.80 1.03 1.29 1.57 2.03 2.29 2.57 2.86 3.20 3.60 4.00 4.57 5.00 5.71 7.14 8.00 8.50 11.00 12.00 12.90 16.00
One-way
cassette
Two-way
cassette
Cassette
Compact
four-way
cassette
Four-way
cassette
Medium static
pressure
Duct
High static
pressure
Fresh air
processing unit
Wall mounted
Floor standing
Heat Recovery
Ventilation Unit
10 11
VVC Series Cooling Only
52
53
Model VDVS-252(8)W/DRN1 VDVS-280(10)W/DRN1 VDVS-335(12)W/DRN1
Power supply V/Ph/Hz 380~415/3/50 380~415/3/50 380~415/3/50
Cooling kW/HP 25.2/8 28.0/10 33.5/12
Capacity
Heating kW 27.0 31.5 37.5
Indoor unit connectable capacity range % 50-130 50-130 50-130
Maximum connectable indoor units nos. 13 16 20
Compressor Type Scroll Scroll Scroll
(DC Inverter) Quantity 01 01 01
Sound pressure level dB(A) 51 52 52
Net (W x H x D) mm 780×1000×550 780×1000×550 780×1000×550
Unit Dimension
Gross (W x H x D) mm 845×1170×600 845×1170×600 845×1170×600
Weight Net / Gross kg 146/155 146/155 146/155
Refrigerant Type R410A R410A R410A
Liquid mm Ø12.7 Ø12.7 Ø15.9
Refrigerant Line Gas mm Ø25.4 Ø25.4 Ø31.8
Oil balance mm Ø6.35 Ø6.35 Ø6.35
Water side connection pipe mm DN32 inner groove DN32 inner groove DN32 inner groove
Drainage pipe outside diameter mm Ø10.0 Ø10.0 Ø10.0
Rated water flow m³/h 5.4 6.0 7.2
Condensor Water in temperature °C 7-45 7-45 7-45
Max. Pressure drop kPa 35 40 48
Indoor Units
For single unit, the footprint is small and maximum capacity is up to 32HP. For combined units, maximum three 32HP
VRF indoor units
units can be combined with capacity up to 96HP.
Ventilation
Heat recovery ventilator (HRV)
Control Systems
Smart control systems
-5°C 55°C
Wide Operation Range
Triple Configurations
for small to large
Longest piping length-actual (equivalent): 175m (200m)
Level difference
Level difference between IDUs and ODU-ODU above (below): 90m (110m)
90m
Precise Oil Control Technology Level difference between IDUs: 30m
Multi Silent Modes *The longest length after 1st branch is 40m as standard but can be extended up to 90m
Duty Cycling under certain conditons. Please contact your local Voltas dealer for further information.
Backup Operation
Refrigerant Cooling PCB Oil Balance pipe not required
Dust-clean Function With the new oil management system, there is no need of oil balance pipe.
45
VRF VVC Series - Cooling Only VRF VVC Series - Cooling Only
HP 8 10 12 14 HP 24 26 28
Model name VVC-224WV2GN1-IN VVC-280WV2GN1-IN VVC-335WV2GN1-IN VVC-400WV2GN1-IN Model name VVC-670WV2GN1-IN VVC-730WV2GN1-IN VVC-785WV2GN1-IN
Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz
kW 22.4 28.0 33.5 40.0 kW 67.0 73.0 78.5
Cooling1 Capacity Cooling1 Capacity
kBtu/h 76.5 95.6 114.4 136.6 kBtu/h 228.8 249.3 268.1
Total capacity 50-130% Total capacity 50-130%
Connected indoor unit Connected indoor unit
Maximum quantity 13 16 20 23 Maximum quantity 39 43 46
Type DC inverter Type DC inverter
Compressor Compressor
Quantity 1 Quantity 2
Type DC Type DC
Quantity 1 Quantity 2
Fan Motor output kW 0.56 Fan Motor output kW 0.56×2
Max.ESP Pa 20 default;60 customization option Max.ESP Pa 20 default;60 customization option
Airflow rate m3/h 10400 10800 Airflow rate m3/h 12200 19600
Type R410A Type R410A
Refrigerant Refrigerant
Factory charge kg 8 Factory charge kg 13 19
Liquid pipe mm Ф12.7 Φ12.7 Liquid pipe mm Φ15.9 Φ19.1
Pipe connections2 Pipe connections2
Gas pipe mm Ф25.4 Ф28.6 Φ28.6 Gas pipe mm Ф31.8 Φ34.9
Sound pressure level3 dB(A) 57 58 60 Sound pressure level3 dB(A) 63 64
Net dimensions (W×H×D) mm 960×1615×765 Net dimensions (W×H×D) mm 1250×1615×765 1585×1615×765
Packed dimensions (W×H×D) mm 1025×1790×830 Packed dimensions (W×H×D) mm 1305×1790×820 1650×1810×840
Net weight kg 188 Net weight kg 278 338
Gross weight kg 204 Gross weight kg 296 362
Ambient temp. Cooling o
C -5oC to 55oC Ambient temp. Cooling o
C -5oC to 55oC
HP 16 18 20 22 HP 30 32
Model name VVC-450WV2GN1-IN VVC-500WV2GN1-IN VVC-560WV2GN1-IN VVC-615WV2GN1-IN Model name VVC-850WV2GN1-IN VVC-900WV2GN1-IN
Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz
kW 45.0 50.0 56.0 61.5 kW 85.0 90.0
Cooling1 Capacity Cooling1 Capacity
kBtu/h 153.7 170.8 191.3 210.0 kBtu/h 290.3 307.4
Total capacity 50-130% Total capacity 50-130%
Connected indoor unit Connected indoor unit
Maximum quantity 26 29 33 36 Maximum quantity 50 53
Type DC inverter Type DC inverter
Compressor Compressor
Quantity 1 2 Quantity 2
Type DC Type DC
Quantity 1 2 Quantity 2
Fan Motor output kW 0.75 0.56×2 Fan Motor output kW 0.56×2
Max.ESP Pa 20 default;60 customization option Max.ESP Pa 20 default;60 customization option
Airflow rate m3/h 11600 12000 12200 Airflow rate m3/h 20600
Type R410A Type R410A
Refrigerant Refrigerant
Factory charge kg 11 13 Factory charge kg 19
Liquid pipe mm Ф15.9 Φ15.9 Liquid pipe mm Φ19.1
Pipe connections2 Pipe connections2
Gas pipe mm Ф31.8 Ф31.8 Gas pipe mm Φ34.9
Sound pressure level3 dB(A) 60 61 62 63 Sound pressure level3 dB(A) 64
Net dimensions (W×H×D) mm 960×1615×765 1250×1615×765 Net dimensions (W×H×D) mm 1585×1615×765
Packed dimensions (W×H×D) mm 1025×1790×830 1305×1790×820 Packed dimensions (W×H×D) mm 1650×1810×840
Net weight kg 197 278 Net weight kg 338
Gross weight kg 213 297 Gross weight kg 362
Ambient temp. Cooling o
C -5oC to 55oC Ambient temp. Cooling o
C -5oC to 55oC
Notes: Notes:
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Diameters given are those of the unit's accessories. 2. Diameters given are those of the unit's accessories.
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. 3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
46 47
VRF VVC Series - Cooling Only VRF VVC Series - Cooling Only
HP 34 36 38 40 HP 50 52 54 56
Model name VVC-950WV2GN1-IN VVC-1000WV2GN1-IN VVC-1070WV2GN1-IN VVC-1115WV2GN1-IN Model name VVC-1400WV2GN1-IN VVC-1455WV2GN1-IN VVC-1520WV2GN1-IN VVC-1570WV2GN1-IN
Combination type 18HP+16HP 18HP+18HP 22HP+16HP 22HP+18HP Combination type 32HP+18HP 28HP+24HP 30HP+24HP 32HP+24HP
Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz
kW 95.0 100.0 107.0 111.5 kW 140.0 145.5 152.0 157.0
Cooling 1
Capacity Cooling 1
Capacity
kBtu/h 324.5 341.6 365.4 380.8 kBtu/h 478.2 496.9 519.1 536.2
Total capacity 50-130% Total capacity 50-130%
Connected indoor unit Connected indoor unit
Maximum quantity 56 59 63 64 Maximum quantity 64
Type DC inverter Type DC inverter
Compressor Compressor
Quantity 2 3 Quantity 3 4
Type DC Type DC
Fan Quantity 2 3 Fan Quantity 3 4
Max.ESP Pa 20 default;60 customization option Max.ESP Pa 20 default;60 customization option
Type R410A Type R410A
Refrigerant Refrigerant
Factory charge kg 11×2 13+8 13+11 Factory charge kg 19+11 19+13
Liquid pipe mm 19.1 Liquid pipe mm 19.1
Pipe connections2 Pipe connections2
Gas pipe mm 31.8 38.1 Gas pipe mm 38.1 41.2
Sound pressure level3 dB(A) 65 Sound pressure level3 dB(A) 66
Net dimensions (W×H×D) mm (960×1615×765)×2 (1250×1615×765)+(960×1615×765) Net dimensions (W×H×D) mm (1585×1615×765)+(960×1615×765) (1585×1615×765)+(1250×1615×765)
Packed dimensions (W×H×D) mm (1025×1790×830)×2 (1305×1790×820)+(1025×1790×830) Packed dimensions (W×H×D) mm (1650×1810×840)+(1025×1790×830) (1650×1810×840)+(1305×1790×820)
Net weight kg 197×2 278+188 278+197 Net weight kg 338+197 338+278
Gross weight kg 213×2 296+204 296+213 Gross weight kg 362+213 362+296
Ambient temp. Cooling o
C -5oC to 55oC Ambient temp. Cooling o
C -5oC to 55oC
HP 42 44 46 48 HP 58 60 62 64
Model name VVC-1170WV2GN1-IN VVC-1230WV2GN1-IN VVC-1285WV2GN1-IN VVC-1350WV2GN1-IN Model name VVC-1635WV2GN1-IN VVC-1700WV2GN1-IN VVC-1750WV2GN1-IN VVC-1800WV2GN1-IN
Combination type 24HP+18HP 26HP+18HP 28HP+18HP 30HP+18HP Combination type 30HP+28HP 30HP+30HP 32HP+30HP 32HP+32HP
Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz
kW 117.0 123.0 128.5 135.0 kW 163.5 170.0 175.0 180.0
Cooling 1
Capacity Cooling 1
Capacity
kBtu/h 399.6 420.1 438.9 461.1 kBtu/h 558.4 580.6 597.7 614.8
Total capacity 50-130% Total capacity 50-130%
Connected indoor unit Connected indoor unit
Maximum quantity 64 Maximum quantity 64
Type DC inverter Type DC inverter
Compressor Compressor
Quantity 3 Quantity 4
Type DC Type DC
Fan Quantity 3 Fan Quantity 4
Max.ESP Pa 20 default;60 customization option Max.ESP Pa 20 default;60 customization option
Type R410A Type R410A
Refrigerant Refrigerant
Factory charge kg 13+11 19+11 Factory charge kg 19×2
Liquid pipe mm 19.1 Liquid pipe mm 19.1
Pipe connections2 Pipe connections2
Gas pipe mm 38.1 Gas pipe mm 41.2
Sound pressure level3 dB(A) 66 Sound pressure level3 dB(A) 66
Net dimensions (W×H×D) mm (1250×1615×765)+(960×1615×765) (1585×1615×765)+(960×1615×765) Net dimensions (W×H×D) mm (1585×1615×765)×2
Packed dimensions (W×H×D) mm (1305×1790×820)+(1025×1790×830) (1650×1810×840)+(1025×1790×830) Packed dimensions (W×H×D) mm (1650×1810×840)×2
Net weight kg 278+197 338+197 Net weight kg 338×2
Gross weight kg 296+213 362+213 Gross weight kg 362×2
Ambient temp. Cooling o
C -5oC to 55oC Ambient temp. Cooling o
C -5oC to 55oC
Notes: Notes:
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Diameters given are those of the unit's accessories. 2. Diameters given are those of the unit's accessories.
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. 3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
48 49
VRF VVC Series - Cooling Only VRF VVC Series - Cooling Only
HP 66 68 70 72 HP 82 84 86 88
Model name VVC-1850WV2GN1-IN VVC-1900WV2GN1-IN VVC-1965WV2GN1-IN VVC-2015WV2GN1-IN Model name VVC-2300WV2GN1-IN VVC-2355WV2GN1-IN VVC-2420WV2GN1-IN VVC-2470WV2GN1-IN
Combination type 30HP+18HP+18HP 32HP+18HP+18HP 28HP+24HP+18HP 32HP+22HP+18HP Combination type 32HP+32HP+18HP 32HP+28HP+24HP 32HP+30HP+24HP 32HP+32HP+24HP
Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz
kW 185.0 190.0 196.5 201.5 kW 230.0 235.5 242.0 247.0
Cooling1 Capacity Cooling1 Capacity
kBtu/h 631.9 647.0 671.1 688.2 kBtu/h 785.6 804.3 826.5 843.6
Total capacity 50-130% Total capacity 50-130%
Connected indoor unit Connected indoor unit
Maximum quantity 64 Maximum quantity 64
Type DC inverter Type DC inverter
Compressor Compressor
Quantity 4 5 Quantity 5 6
Type DC Type DC
Fan Quantity 4 5 Fan Quantity 5 6
Max.ESP Pa 20 default;60 customization option Max.ESP Pa 20 default;60 customization option
Type R410A Type R410A
Refrigerant Refrigerant
Factory charge kg 19+11×2 19+13+11 Factory charge kg 19×2+11 19×2+13
Liquid pipe mm 19.1 22.2 Liquid pipe mm 22.2 25.4
Pipe connections 2
Pipe connections 2
Gas pipe mm 41.2 44.5 Gas pipe mm 44.5 50.8
Sound pressure level3 dB(A) 67 67 Sound pressure level3 dB(A) 68 68
Net dimensions (W×H×D) mm (1585×1615×765)+(960×1615×765)×2 (1585×1615×765)+(1250×1615×765)+(960×1615×765) Net dimensions (W×H×D) mm (1585×1615×765)×2+(960×1615×765) (1585×1615×765)×2+(1250×1615×765)
Packed dimensions (W×H×D) mm (1650×1810×840)+(1025×1790×830)×2 (1650×1810×840)+(1305×1790×820)+(1025×1790×830) Packed dimensions (W×H×D) mm (1650×1810×840)×2+(1025×1790×830) (1650×1810×840)×2+(1305×1790×820)
Net weight kg 338+197×2 338+278+197 Net weight kg 338×2+197 338×2+278
Gross weight kg 362+213×2 362+296+213 Gross weight kg 362×2+213 362×2+296
Ambient temp. Cooling o
C -5oC to 55oC Ambient temp. Cooling o
C -5oC to 55oC
HP 74 76 78 80 HP 90 92 94 96
Model name VVC-2070WV2GN1-IN VVC-2130WV2GN1-IN VVC-2185WV2GN1-IN VVC-2250WV2GN1-IN Model name VVC-2535WV2GN1-IN VVC-2600WV2GN1-IN VVC-2650WV2GN1-IN VVC-2700WV2GN1-IN
Combination type 32HP+24HP+18HP 32HP+26HP+18HP 32HP+28HP+18HP 32HP+30HP+18HP Combination type 32HP+30HP+28HP 32HP+30HP+30HP 32HP+32HP+30HP 32HP+32HP+32HP
Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz Power supply V/Ph/Hz 380-415V 3N~ 50/60Hz
kW 207.0 213.0 218.5 225.0 kW 253.5 260.0 265.0 270.0
Cooling1 Capacity Cooling1 Capacity
kBtu/h 707.0 727.5 746.3 768.5 kBtu/h 865.8 888.0 905.1 922.2
Total capacity 50-130% Total capacity 50-130%
Connected indoor unit Connected indoor unit
Maximum quantity 64 Maximum quantity 64 64 64 64
Type DC inverter Type DC inverter
Compressor Compressor
Quantity 5 Quantity 6
Type DC Type DC
Fan Quantity 5 Fan Quantity 6
Max.ESP Pa 20 default;60 customization option Max.ESP Pa 20 default;60 customization option
Type R410A Type R410A
Refrigerant Refrigerant
Factory charge kg 19+13+11 19×2+11 Factory charge kg 19×3
Liquid pipe mm 22.2 Liquid pipe mm 25.4
Pipe connections2 Pipe connections2
Gas pipe mm 44.5 Gas pipe mm 50.8
Sound pressure level3 dB(A) 68 Sound pressure level3 dB(A) 68
Net dimensions (W×H×D) mm (1585×1615×765)+(1250×1615×765)+(960×1615×765) (1585×1615×765)×2+(960×1615×765) Net dimensions (W×H×D) mm (1585×1615×765)×3
Packed dimensions (W×H×D) mm (1650×1810×840)+(1305×1790×820)+(1025×1790×830) (1650×1810×840)×2+(1025×1790×830) Packed dimensions (W×H×D) mm (1650×1810×840)×3
Net weight kg 338+278+197 338×2+197 Net weight kg 338×3
Gross weight kg 362+296+213 362×2+213 Gross weight kg 362×3
Ambient temp. Cooling o
C -5oC to 55oC Ambient temp. Cooling o
C -5oC to 55oC
Notes: Notes:
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Diameters given are those of the unit's accessories. 2. Diameters given are those of the unit's accessories.
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. 3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
50 51
The outdoor units capacity ranging from 7.2kW to 17.5kW which is ideal for small offices, villas, apartments and shops,
Notes:
1. Cooling: indoor temperature 27°C DB/19°C WB; outdoor temperature 35°C DB.
52 53
56
58 68
60 72
64 74
66 76
56 57
58 59
60 61
62 63
64 65
66 67
68 69
70 71
72 73
74 75
76 77
82
84
86
92
96
102
112
80 81
82 83
84 85
86 87
88 89
Schedule Management Wiring Flexibility
Daily, weekly or annual schedules can be used to set unit settings such as on/off, operating mode, set temperature, fan The controllers can be connected to the master outdoor unit directly.
speed and swing.
6.2-inch
X,Y
Up to 64
indoor units
X,Y
CONTROL SOLUTIONS
LAN Access Up to 8 refrigerant systems
Up to
X,Y,E P,Q,E P,Q,E P,Q,E
A desktop or laptop PC can be used for browser-based access via a LAN connection. 64
Up to 8 refrigerant systems
10.1-inch
X,Y,E Up to
P,Q,E P,Q,E P,Q,E
64
Up to 6 XYE
Ports
Up to 8 refrigerant systems
LAN X,Y,E Up to
P,Q,E P,Q,E P,Q,E
64
90 91
92 93
94 95
96 97
98 99
100 101
102 103
104 105
106 107
108 109
110 111
112 113
114 115
116 117
118 119
120 121