Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

4

6
x
23/05/21

8 8

PERSIAN
RESTAURANT

GENERAL NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
MENTIONED SIZE DRAWING SET IS FULL SIZE.

MEP COORDINATION
REFERENCE NUMBER DATE TITLE

REFERENCE DESIGN DRAWINGS


REFERENCE NUMBER DATE TITLE
1
1 Push
Button
to
Keep clear Open

REFERENCE SHOP DRAWINGS


REFERENCE NUMBER DATE TITLE

RELATED DOCUMENTS
REFERENCE NUMBER DATE TITLE

8 8

4 SECTION
SCALE 1:10

2 ELEVATION 3 ELEVATION
SCALE 1:10
SCALE 1:10 IRON MONGERY G-0622b
HARDWARE SET - WD/01/05/AU/FD60(23/ID03)(SB)
DEC GENERAL NOTES:
3 1. FINAL DIMENSIONS TO BE AS PER SITE ITEM
No. ITEM DESCRIPTION MFR. QTY UNIT FINISH IMAGE SCOPE
CONDITIONS. CODE
2.CONTRACTOR TO ENSURE THAT THE
DOCUMENTS LISTED BELOW,
BUTNOT LIMITED TO ARE FOLLOWED IN ITS
ENTIRETY DURING
SITE EXECUTION, IFC DRAWINGS, INSTRUCTIONS,
DESIGNER’S/CLIENT’S SIGNED OFF
DRAWINGS,SDIRS,RFI RESPONSES & ETC. T4

3. DEVIATING FROM THE VARIOUS APPROVED 16


17

DURING EXECUTION 15

OF WORKS WILL RESULTIN REJECTION OF WIR 14

4. ALL MATERIALS TO BE AS PER APPROVED 13

SAMPLES/MOCK-UPS
T3

5. CONTRACTOR TO ENSURE ALL MEP ELEMENTS


ARE AS PER APPROVEED MEP INDIVIDUAL
SERVICES SHOP DRAWINGS. PERSIAN RESTAURANT KEY PLAN
6. COORDINATE WITH C6 PACKAGE FOR
PARITIONS.
7. ALL ROUGH CARPENTRY, DOOR & FRAME
WORKS TO BE AS PER SPECIFICATION.
8. ALL IRONMONGARIES TO BE AS PER APPROVED
SAMPLES BY THE DESIGNER.
9. FINAL APPROVAL SUBJECT TO MOCKUP
APPROVAL.

REV DATE DESCRIPTION DRN CHK APP


5
2

1 SECTION/PLAN @ DOOR LEAF PANEL DOOR SCHEDULE


SCALE 1:10 DOOR FRAME SIZE CLEAR OPENING DOOR LEAF SIZE
STRUCTURAL
ACCESS
THE ROYAL ATLANTIS RESORT
DOOR DOOR TYPE DOOR DOOR FRAME OPENING FIRE STC
No. ROOM NAME HARDWARE SET CONTROL QUANTITY REMARKS AND RESIDENCES
7 STEEL FRAME PLAN DETAIL 8 STEEL FRAME ELEVATION DETAIL
NUMBER AS PER IBI TYPE HANDING TYPE
WIDTH HEIGHT DEPTH WIDTH HEIGHT WIDTH HEIGHT THK. WIDTH HEIGHT
RATING RATING
TYPE
Palm Jumeirah Crescent, Dubai U.A.E.
7
SCALE 1:2 SCALE 1:2 6 DETAIL
SCALE 1:2 DR IBI GROUP ARCHITECTS
95 St. Clair Ave. West, Suite 200
Toronto, ON, M4V1N6, Canada
tel (416) 924-9966 fax (416) 924-9067
DOOR HANDING ibigroup.com

OFFICE 2805 - 2810,CONCORD TOWER,


MEDIA CITY, DUBAI, UNITED ARAB EMIRATES,
P.O. BOX: 79593
TEL.: 04-2989220, FAX: 04-2989210
www.decengineering.net

Abu Dhabi UAE Office Dubai UAE office


P.O. BOX 73814 P.O. BOX 334138
Tel.: +971 2 499 5 444 Tel.: +971 4 346 7 711
Fax: +971 2 499 5 400 Fax: +971 4 346 7 722
email: decov@decovision.ae email: decov@decovision.ae

PACKAGE F5C
As per Sub-Clause 5.2 [Submission and PERSIAN RESTAURANT - GROUND FLOOR
Approval] of the CoC, ‘no such approval FOH - CORRIDOR / ROSE BAR
(nor any absence of disapproval) shall G-0622b - 1HR. FIRE RATED DOOR DETAILS
release the Contractor from any of its SHEET (1 OF 1)
obligations or liabilities (including its
responsibility for (and liability arising out of) PJCRC 19-27C / PALM JUMEIRAH
its duty to design) under the Contract’; it is
the Contractor’s responsibility to coordinate
with multiple trades such that the works are 23/10/19 ROC AAR A0 AS DRAWN
executed as per contract documents and to
the project standards. If the works
7 executed on site does not meet the project
5 TRA DCV SDG ID
DETAIL requirements such works will be rejected 9 KEY PLAN
SCALE 1:2 during inspection and the Contractor will SCALE NTS
have to modify these works at their time
GEN 20094 01
and cost."