Professional Documents
Culture Documents
Zed-Co-Pic3-G+3a-Bep - Small Power
Zed-Co-Pic3-G+3a-Bep - Small Power
CLIENT:
CONCRETE
STRUCTURAL SLAB
150
ADAPTOR
CONCRETE SLAB
DESIGN CONSULTANT:
NOTES:
· CONDUIT SIZE TYPE SHALL BE AS PER APPROVED
SHOP DRAWING ACCORDING TO CONDUIT FILLING
RATIO
F.F.L
SUPERVISION CONSULTANT:
8Y/DB-G4 8Y/DB-G4
DP-01-TYPICAL DP-06-WALL MOUNTED 3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT
HEIGHT SUBELECTRICAL
INSTALLATION CONTRACTOR:
1080
1080
151
CONCRETE SLAB
777
641
22Y/DB-G4
3*6mm, Φ25 PVC CONDUIT
742
824
938
938
700
22Y/DB-G4 22Y/DB-G4
FOR SU-03
966
1082
32A
3*6mm, Φ25 PVC CONDUIT 3*6mm, Φ25 PVC CONDUIT
1459
P P P P
KEY PLAN
8Y/DB-G4 8Y/DB-G4
759
3*3mm, Φ25 PVC CONDUIT P P P P 3*3mm, Φ25 PVC CONDUIT
1916
WOODEN FRAME
1744
1996
1852
1485
FOR SU-03 FOR SU-03
1440
32A FOR SU-03 FOR SU-03
EXHAUST FAN FOR SU-03 FOR SU-03 FOR SU-03
986
Filling Ratio 3*6 3*6mm, Φ25 PVC CONDUIT
D 32A
32A
D
32A 32A
312
D
32A
32A D
1512 457
1377 156 480 465
459
26Y/DB-G4 26Y/DB-G4
NOTES: 3*6mm, Φ25 PVC CONDUIT 3*6mm, Φ25 PVC CONDUIT
CONDUIT SIZE TYPE SHALL BE AS PER APPROVED FOR IEC FOR IEC FOR IEC
SHOP DRAWING ACCORDING TO CONDUIT FILLING
1275
820
RATIO 9B/DB-G4
974
9B/DB-G4
2028
377
2053
3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT
361
INDOOR OUTDOOR 17R/DB-G4 1273
17R/DB-G4 17R/DB-G4
17R/DB-G4 308
919
SOCKET OUTLET 3*3mm, Φ25 PVC 3*3mm, Φ25 PVC 3*3mm, Φ25 PVC 3*3mm, Φ25 PVC
17R/DB-G4 FOR DISH WASHER
CONDUIT FOR EWH FOR EWH CONDUIT CONDUIT 17R/DB-G4
CONDUIT
3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT
FOR DISH WASHER
FOR DISH WASHER
FOR DISH WASHER
PROVISION AC PROVISION AC PROVISION AC
FOR EWH PROVISION AC FOR EWH
833
450
889
986
544
544
16R/DB-G4 FOR HOB&OVEN
3*4mm, Φ25 PVC CONDUIT FOR HOB&OVEN 16R/DB-G4 3*4mm, Φ25 PVC CONDUIT
822
769
3*3mm, Φ25 PVC CONDUIT FOR HOB&OVEN
1475 249 3*3mm, Φ25 PVC CONDUIT FOR HOB&OVEN
250
175
FINISHED FLOOR LEVEL FOR FRIDGE FOR FRIDGE
2330
16R/DB-G4 FRIDGE FOR FRIDGE
16R/DB-G4
1730
SCREED PVC CONDUIT
1387
1331
1475
3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT
CONCRETE SLAB
816
875
857
80
385
DETAIL# SCALE FOR EWH FOR EWH
N.T.S
9B/DB-G4 9B/DB-G4
3*3mm, Φ25 PVC CONDUIT
DP-02-TYPICAL 3*3mm, Φ25 PVC CONDUIT
13R/DB-G4
13R/DB-G4 3*3mm, Φ25 PVC CONDUIT
INSTALLATION DETAIL 18B/DB-G4
3*3mm, Φ25 PVC CONDUIT
17R/DB-G4 17R/DB-G4 18B/DB-G4
DP-05-TYPICAL DETAIL 3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT 3*3mm, Φ25 PVC CONDUIT
FOR SOCKET FED FROM
FOR EXHAUST FAN
UNDER FLOOR TILES
18B/DB-G4
3*3mm, Φ25 PVC CONDUIT
CONCRETE SLAB
18B/DB-G4
PVC CONDUIT
FACADE/WALL EDGE
EQ EQ
NOTES:
· CONDUIT SIZE TYPE SHALL BE AS PER APPROVED
PVC CONDUIT
SHOP DRAWING ACCORDING TO CONDUIT FILLING
RATIO
SOCKET OUTLET
1200
00 JAN-2023
450
PROJECT:
FINISHED FLOOR LEVEL
SCREED
ZED EAST - PHASE 1
CONCRETE SLAB
NEW CAIRO
BUILDING/UNIT:
ZE-P1C3-PKB-CPC-SHD-G+3A-SP-330-00
SIZE
A0
REV.
00
CONDUIT FROM CEILING FLUSH MOUNTING DETAIL DRAWN BY CHECKED BY APPEOVED BY DATE