Conferences By Paul Simonds
Electricity Forum Training
Institute(EFTI)
Electronics and microprocessor-based equipment have become an
Industry Conferences Download
Directories integral part of our everyday lives. As technology advances and Our
Issues
T&D Companies electronic equipment becomes faster, it also becomes more sensitive
T&D Products/Services to the hazards created by poor grounding and bonding practices.
Generation Companies Technology has advanced the speed of electronics by reducing the
Generation Products/Services distance between components and lowering the voltage required to
Product Showcase
operate the system. While this increases the speed of the equipment,
Buy Products On-Line
it also makes the equipment more vulnerable to damage at a lower
Features
Electricity Today Magazine
voltage difference, thereby making the grounding and bonding of the
Electricity News equipment much more important than it was during the days of glass
Classifieds tube, high voltage equipment.
Careers
Industry Links Ask any power quality expert today about equipment grounding and
Bookstore they will tell you, "poor grounding practices are second only to
improper wiring as the leading cause of equipment malfunction." The
standards for equipment performance mandate the installation and
maintenance of a reliable, low resistance path to ground. Most
electronic equipment today operates at a very low voltage and is
often subjected to potentially lethal hazards, many of which are
generated by the operation of the equipment itself.
Earth Grounding
As with any construction project, it is always best to work from the
ground up, so the ground connection is typically where one should
start with a grounding system design. A ground electrode is "a
conductor or group of conductors in intimate contact with the earth
for the purpose of providing a connection with the soil". This
1 of 5 1/3/2008 12:32 PM
Electricity Today Magazine Article -- Power System Data Communica... http://www.electricity-today.com/et/issue0601/i06_grounding.htm
Soil Resistivity
The soil upon which an equipment site is constructed is the dynamic
conductor for all fault currents from the equipment, whether they are
natural or man-made. It is very similar to the chassis ground in a
vehicle. All grounds, no matter how they are routed, eventually
reference back to the earth itself. And just as different types of metals
can be better types of conductors than other metals, so too can
different types of soils. Most soils naturally contain varying amounts
of electrolytes that conduct electricity. As a result, the addition of
moisture will enhance or reduce the conductive properties of that soil.
As a general rule, soil with a higher moisture content will have a lower
electrical resistance.
2 of 5 1/3/2008 12:32 PM
Electricity Today Magazine Article -- Power System Data Communica... http://www.electricity-today.com/et/issue0601/i06_grounding.htm
In other words, instead of helping the lightning get into the ground,
where it wants to go in the first place, they over specify products to
contain the lightning damage once it has already entered the
equipment shelter. Lightning is a very high frequency event. In
laymen's terms this means it is an extremely fast current. Since
lightning is a high frequency event, the impedance of the paths to
ground, as well as the ground resistance, is very important in
designing an effective grounding system.
3 of 5 1/3/2008 12:32 PM
Electricity Today Magazine Article -- Power System Data Communica... http://www.electricity-today.com/et/issue0601/i06_grounding.htm
It is imperative that this test be performed before tying into any other
ground source; for example, the power company ground or telephone
company ground. The reason for testing before it is tied into any
other ground is to verify that your system has met the designed
ground resistance value without influence from any outside sources. If
the test is performed after the power is connected, the Clamp-On
ground resistance tester can be utilized. This involves clamping onto
the power neutral between the transformer and the site ground. The
user must be aware that a 0.7 ohm reading indicates a continuity loop
and is not a ground resistance reading.
4 of 5 1/3/2008 12:32 PM
Electricity Today Magazine Article -- Power System Data Communica... http://www.electricity-today.com/et/issue0601/i06_grounding.htm
The site survey will show any physical barriers such as rock, high
resistivity soil, power lines or any other variables that could affect
the earth-ground resistance in the installation area. Once this
information is obtained, an effective and properly designed grounding
system can be installed.
Conclusion
A properly designed, low-resistance grounding and bonding system is
a major component of a well-protected and efficient facility. A
properly designed and installed grounding system is an integral part
of any site and should be designed and purchased with the same
research and consideration as any other critical piece of equipment.