VALVE BOX

PVC MALE x PVC UNION ADAPTOR


VALVE LABEL TO BE TIED WITH GATE VALVE
USING STAINLESS STEEL CHAIN TYPE TIE
BRONZE GATE VALVE
PVC NIPPLE CLIENT
GLASS FILLED NYLON SOLENOID
VALVE WITH PRESSURE REGULATOR
VALVE LABEL
FINISH GRADE
WARNING TAPE
SELECTED BACK FILL / PLANTING SOIL
GROUND LEVEL
PVC MALE x PVC UNION ADAPTOR LEAD CONSULTANT
SEAL ALL OPENINGS TO VALVE BOX
300

DUCT SCHEDULE FOR CONTROL CABLE CABLE MARKERS


NUMBER OF CABLES CONDUIT SIZE
1-4 25 mm
600

5-8 40 mm
9-14 50 mm
15-30 75 mm UPVC PIPE
> 30 100 mm
MAINLINE
300

IRRIGATION PIPE BLOCKWORK SUPPORT


100mm OF GRAVEL
CABLE CONDUIT
FOAM TYPE SEALANT
300

BEDDING SAND CONTROL WIRE IN CONDUIT


PIPE FROM PULL BOX

1 UPVC PIPE INSTALLATION 4 SOLENOID VALVE ASSEMBLY : TYPICAL SECTION


NOT TO SCALE NOT TO SCALE

D D AREA OF CONCRETE (sq.m.) EPR = 5N/sq.cm.


PIPE DIA. TEE 90° 45° RECESSED COVER
D

3" 0.294 00.42 0.23 WATERPROOF CONNECTOR


4" 0.486 00.69 0.37 VALVE BOX
6" 1.050 01.48 0.80
8" 1.770 01.48 0.80 VALVE LABEL
FINISH GRADE
VERTICAL BENDS(UPTHRUST)
A

A
B

MINIMUM CONCRETE VOLUME (cu.m.)


PIPE DIA. 90° 45° 22.5° 11.25°
3" 00.88 0.48 0.24 0.12 CABLE MARKER
4" 01.46 0.79 0.40 0.20
6" 03.13 1.70 0.86 0.44
TEE PLAN ELBOW PLAN 8" 05.31 2.87 1.46 0.73
200mm

THRUST BLOCK DIMENSIONS - 45° ELBOW


PIPE DIA. A B C D FOAM TYPE SEALANT
2" 0.250 0.250 0.450 0.500
3" 0.440 0.300 0.520 0.700
4" 0.650 0.350 0.570 0.700
6" 1.000 0.400 0.800 1.000 GRAVEL KEY PLAN
8" 1.240 0.550 1.100 1.200
THRUST BLOCK DIMENSIONS - 90° ELBOW
PIPE DIA. A B C D
c

2" 0.380 0.500 0.350 0.500 NOTES


3" 0.700 0.600 0.500 0.700
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
4" 0.900 0.760 0.800 0.700 OTHERWISE STATED
6" 1.480 0.970 1.000 1.000
8" 2.510 1.300 1.000 1.200 CABLE CONDUIT 2. THIS DRAWING TO BE READ IN CONJUNCTION
TEE & ELBOW SECTION
WITH ALL OTHER CONTRACT DRAWINGS, AND
RACKS
BICYCLE
10 NOS OF

BICYCLE RACKS
8 NOS OF

THRUST BLOCK DIMENSIONS - TEE THE SPECIFICATIONS


DW
RF

wooden door
with glass
RF

DB

WITH GLASS
DB

WOODEN DOOR
DB

1 2 3
DW RF

DW

WOODEN DOOR
WITH GLASS
RF

DB

DOOR
WOODENGLASS
WITH
DW DB

DB

RF

NOTES :
RF
DW

PIPE DIA. A B C D
DW

- MAKE UP THRUST BLOCK AGAINST 2" 0.370 0.200 0.370 0.500 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
UNDISTURBED SOIL 3" 0.545 0.250 0.545 0.700 PRODUCING A COMPLETE SET OF
NOTES :
- PROTECT FILLING WITH DOUBLE WRAP CO-ORDINATED SHOP DRAWINGS FOR ALL
4" 0.700 0.300 0.700 0.700 - PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX ELEMENTS OF THE IRRIGATION WORK FOR THE
HEAVY DUTY POLYETHLENE SHEETING 6" 1.050 0.400 1.000 1.000 - COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL ENGINEER'S APPROVAL, PRIOR TO THE
8" 1.770 0.400 1.000 1.200 COMMENCEMENT OF THE WORKS
2 THRUST BLOCK ARRANGEMENT: TYPICAL PLANS & SECTION 5 PULL BOX DETAILS IN SOFT LANDSCAPE AREA : TYPICAL SECTION 4. THE CONTRACTOR SHALL MAKE HIMSELF FULLY
NOT TO SCALE NOT TO SCALE AWARE OF THE SITE CONDITIONS, EXISTING
GROUND WATER LEVELS, NECESSITY FOR BACK PRELIMINARY - NOT FOR CONSTRUCTION
PROPPING EXCAVATED AREAS AND EXISTING
SERVICES ISSUE/REVISION

5. CONTRACTOR TO PRODUCE A REPRESENTATIVE


SAMPLE FOR THE ENGINEER'S APPROVAL FOR
EACH ELEMENT, TO WHICH THE WORKS ON SITE
HARDSCAPE AS PER DESIGN MUST CONFORM
NOTE : EXPANSION COIL TO BE MADE
IDENTIFICATION TAG 6. THRESHOLDS TO CHANGES IN LEVEL, BUILDINGS,
USING MINIMUM 1m EXTRA CABLE.
300x300 CLEAR OPENING DUCTILE IRON / ETC. TO BE FLUSH WITH NOMINAL FALLS AWAY
STAINLESS STEEL COVER WITH "IRRIGATION
PULL BOX" CASTED IN ARABIC & ENGLISH. 7. SLEEVES SHALL BE PROVIDED FOR ALL B
REVISED DETAILED DESIGN
27.01.2023 JH AP
IRRIGATION PIPES WHICH CROSS ANY HARD SUBMISSION
LANDSCAPE / STRUCTURAL ELEMENTS.
A DETAILED DESIGN SUBMISSION 20.01.2023 CM AP
8. PIPES SHALL BE ENCASED IN CONCRETE IF IR DESCRIPTION DATE CHK APP
LENGTH OF CROSSING IS MORE THAN 12m OR
WATERPROOF WIRE CONNECTOR SUFFICIENT DEPTH (MINIMUM 500mm) IS NOT
CABLE MARKERS
AVAILABLE. DETAILED DESIGN
9. ALL THE VALVE BOXES SHALL BE LOCATED IN PROJECT
SEALANT (FOAM TYPE) SOFT LANDSCAPE AREAS UNLESS APPROVED BY
THE ENGINEER. VALVE BOXES / MANHOLES IN PROPOSED B+G+14 STOREY
HARD LANDSCAPE AREA SHALL BE PROVIDED
WITH D.I.RECESSED MANHOLE COVERS.
RESIDENTIAL BUILDING
PAVING/ROAD GROUND LEVEL
ON PLOT NO. 3262966, DHCC2
IRRIGATION DUCTS SCHEDULE
10. EACH DRIP RISER FLOW SHALL NOT EXCEED 400
LPH. NUMBER OF DRIP RISERS SHOWN ON
AL JADAF, DUBAI - UAE.
A (O.D) B (O.D) DRAWING SHOULD BE VERIFIED TO MEET THIS DRAWING TITLE
32 mm 75 mm GRAVEL CRITERIA.
PIPE: REFER COLUMN A IN IRRIGATION
VARIES

40 mm 100 mm
min 500
DUCTS SCHEDULE FOR PIPE SIZES
50 mm 100 mm
SOLID BLOCK WORK  
32 mm 75 mm
DUCT: REFER COLUMN B IN IRRIGATION DUCTS
SCHEDULE FOR DUCT SIZES (UPVC CLASS C)
min 500
75 mm 150 mm
LARGE BEND TYPICAL IRRIGATION DETAIL
150 mm 300 mm CABLE CONDUIT SHEET 1 OF 2
 
VARIES

3 IRRIGATION DUCT 6 PULL BOX DETAILS IN HARD LANDSCAPE AREA : TYPICAL SECTION DRAWING NUMBER
NOT TO SCALE NOT TO SCALE
CLL-LSC-DWG-P103-SW-00-7301
PROJECT NUMBER SCALE SHEET SIZE REV

12147.001 AS SHOWN A1 B