Professional Documents
Culture Documents
Sum Hyd Cal
Sum Hyd Cal
DI NO. 8 (LOT 34476), JALAN BRP 4/1, SEKSYEN U20, BUKIT RAHMAN PUTRA, 40160
SHAH ALAM, SELANGOR DARUL EHSAN.
The purpose of this report is to find out the available actual pressure head is sufficient to
supply the water at highest level of bib tap at ablution area. If the discharge residual
pressure at the ablution area is greater than 2.0m, hence the proposed pipe size is
satisfied.
Where ;
Static head = vertical distance between the bip tap level and level of
distribution pipe in floor slab
= 1.05 m
Hence, Min. Residual Pressure = Head Available – Head Required > 2.0 m
= 4.95 m – 2.64 m > 2.0 m
= 2.31 m > 2.0 m
3. CONCLUSION.
It can be seen that the discharge residual pressure at the highest level of bib tap at
ablution area is 2.31 meter. Since the discharge residual pressure is greater than
2.0 meter, then the proposed pipe size are acceptable.