Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

YANBU STRATEGIC TANKS

Subject DATA SHEETS Number


Fibre Optic Cable 4005

Doc. - No.: Q A 1 0 - G - 3 0 3 2 Rev. 0

No. Description Unit Required Guaranteed Notes


1 Optical Fibre
1.1 Standards
1.1.1 Reference Specifications S07
1.1.2 Product specification ITU-T G.652 D or
IEC 60793-2-50,
Cat. B 1.1
1.1.3 Dimension IEC 60793-2-50,
Cat. B 1.1
1.1.4 Transmission IEC 60793-2-50,
Cat. B 1.1
1.1.5 Mechanical IEC 60793-2-50,
Cat. B 1.1
1.2 Transmission Characteristics
1.2.1 Attenuation 4,5 at 1 310 nm dB/km ≤ 0.40
at 1 550 nm dB/km ≤ 0.25
at 1 6XX nm dB/km ≤ 0.40
1.2.2 Variation in at 1 310 nm dB/km ≤ 0.05
attenuation at 1 550 nm dB/km ≤ 0.10
1.2.3 Zero dispersion wavelength, 0 nm 0 ≤ 1 324
1 300 ≤ 
1.2.4 Zero dispersion slope Ps/nm ≤ 0.093
1.2.5 Nominal MFD6 at 1 310 nm (tolerance) µm 8.6 – 9.5
(± 0,7)
1.2.6 Cable cut-off wavelength nm ≤ 1 260
1.2.7 Macro bending 7 loss at 1 550 nm dB ≤ 0.5
1.3 Additional Construction
1.3.1 Core refractive index constant
index profile step index
structure material silica glass
1.3.2 Cladding material silica glass/
Other requirements matched cladding
depressed
cladding
1.3.3 Primary coating material Acrylic
Other requirements two layers
mechanically tight
UV-protection
2 Fibre Optic Cable
2.1 General
2.1.1 Product specification ITU-T L.10 or
IEC 60794-3-10

+20°C ± 3°C
nm = 1 550 +30/-70nm / 1 6XX nm = 1 6XX ≤ 25nm
Mode Field Diameter
a 75 mm diameter mandrel

Page 1of 2
YANBU STRATEGIC TANKS
Subject DATA SHEETS Number
Fibre Optic Cable 4005

Doc. - No.: Q A 1 0 - G - 3 0 3 2 Rev. 0

No. Description Unit Required Guaranteed Notes


2.1.2 8 No. 72
Number of fibres
2.1.3 Lifetime year ≥ 30
2.1.4 Cable length (per drum) km ≥ 6 (- 0 … +1%)
2.1.5 Temperature operational °C 0 to +45
Laying °C 0 to +50
Storage °C 0 to +50
2.1.6 Fibre optic cable non-metallic
2.1.7 Allowable bending radius mm -
2.1.8 Allowable tractive force N ≥ 2.500
2.1.9 Fibre colouring IEC 60304
2.1.10 Secondary coating loose tube
2.1.11 Traction elements fully dielectric
2.1.12 Cavities 9 filled 6
2.1.13 Cable cladding water proof
2.1.14 Rodent protection Layer of glass yarns
or similar
2.1.15 Termite protection Polyamide/Nylon
overcoat

2.2 Additional Construction Requirements


2.2.1 Cable cladding 10 - material PE black
2.2.2 Cable cladding - thickness 11 mm min. 1,5
2.2.3 Cable outer-diameter
2.2.4 Weight per drum

8
All optical fibres of all cable have the same manufacturer. The fibers shall be distributed equally to all tubes. Maximum number of
tubes shall be used. No fillers allowed.
9
Filling compound in tubes and cable core must not impair the colour of the secondary coating, must be easy removable from
primary and secondary coating, must be non-toxic, scentless and unharmful to human skin
10
acc. IEC 60811-4-1
11
acc. IEC 60189-1

Page 2of 2