Blast Chiller - Shock Freezer mod.

BE-R151

TECHNICAL FEATURES:

• Constructed in AISI 304 stainless steel, exterior with


scotch-brite finish
• Cavity with rounded corners, in AISI 304 polished finish
• Insulation in high density polyurethane foam (approx.
42 kg / m3) 60mm thick (50mm mod 3 trays), HCFC free
• 30 mm reinforced top, standard on modd 5 10 and 15
trays
• Shaped internal bottom for containment, with central
drain for washing water
• Reversible door with special kit (except 3 trays)
• Evaporator with anticorrosive treatment in cataphoresis
• High thermal output condenser
• Ergonomic handle and magnetic gaskets on the 4 sides
of the door
• Heating element to keep the door gasket soft
• Door lock at 110 ° for inserting trays

INTERNAL SETUP:

• Tray holder structure in AISI304 ionox steel, in wire,


easily removable for easy cleaning
• Possibility to insert 15 GN1/1-EN1 trays with 67 mm
pitch
• Microswitch that blocks the ventilation when the door is
opened
• Conical core probe included

FUNCTIONS:

• Pre-cooling
• Shock Freezing SOFT and HARD SETUP:
• Blast Chilling SOFT and HARD
• Time control or with core probe
• 9 pre-set cycles, modifiable
• Automatic storage at the end of the cycle

COOLING SYSTEM:

• R452A refrigerant fluid


15 TRAYS 530x325 + REMOVABLE Electronic
• Standard air condensation 600x400 TRAYHOLDER membrane control
• High performance hermetic compressor
• High pressure fans
• Manual defrosting with automatic dissipation of FEATURES:
defrosting water
• Climate class 5 (tropicalized + 43 ° C)

CONTROL BOARD:

• Semi touch electronic control


• HACCP system with alarms storage
• BT or WiFi communication (opt.) With special kit, for STAINLESS STEEL THICKNESS 60 mm ROUNDED REMOVABLE
monitoring via APP AISI304 CORNERS DOOR GASKET
WITHOUT
TOOLWS

INDIRECT EVAPORATOR DEFROSTING WITH CONICAL CORE


AIRFLOW WITH VENTILATION PROBE
CATAPHORESIS
TREATMENT

PRIMAX Srl
Via Gemona, 14/16 - 33078 San Vito al Tagliamento (PN)
Tel: +39 0434 630779 Fax: +39 0434 630956
https://www.primaxsrl.com Email: info@primaxsrl.com
Blast Chiller - Shock Freezer mod. BE-R151
SCHEDA TECNICA BE-R151
Measure pan mm GN1/1-EN1

TOTAL 15

Pitch mm 67

Trays insertion Crosswise

Net dimensions (WxDxH) mm 790x820x1800

Depth with 90° door mm 1550

Net door opening dimensions (WxH)


670x1040
mm

Net nternal depth mm 490

Internal volume l 341.432

Insulation thickness mm 60

Insulated floor thickness mm 60

Net weight kg 184

Packing Pallet + carton

Packing dimensions (WxDxH) mm 820x910x1930

Packing volume m3 1.44

Gross weight kg 199

Max power consumption KW 2622

Max absorbed current A 5.7

Power supply V/~/Hz 400/3/50

Electric cable n° x mm² 5x1,5 mm2

Temperature range °C -37/-41

Refrigeration system Ventilated

Blast chilling yield +90°C-> +3°C


48
within 90' kg/ciclo
Shock freezing yield +90°C->-18°C
32
within 240' kg/ciclo

Refrigerant gas R452A

Refrigerant gas quantity, water


1240
cooling g

Cooling power EN12900 W 2062

Compressor hp 2

Defrosting Forced ventilation

Climatic class 5

PRIMAX Srl
Via Gemona, 14/16 - 33078 San Vito al Tagliamento (PN)
Tel: +39 0434 630779 Fax: +39 0434 630956
https://www.primaxsrl.com Email: info@primaxsrl.com
Blast Chiller - Shock Freezer mod. BE-R151

790 820
BE15
800

1040
1800

150

95 600 95 60 620 60
1550

670 Abbattimento positivo


Blast chilling
95 Abbattimento negativo
°
Shock freezing
Hard o soft
Hard or soft

Tasto decremento
Decrement key
Tasto incremento
Increment key
DESCRIZIONE PANNELLO COMANDI
CONTROL PANEL DESCRIPTION Start / stop

PRIMAX Srl
Via Gemona, 14/16 - 33078 San Vito al Tagliamento (PN)
Tel: +39 0434 630779 Fax: +39 0434 630956
https://www.primaxsrl.com Email: info@primaxsrl.com