Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Service Information

Document Title: Function Group: Information Type: Date:


Side mount housing, 926 Service Information 2/27/2018
removing
Profile:
HB70

Side mount housing, removing


Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
HB70

Op nbr 926-103

Total procedure time (hr): 0.90

1. Prepare 3 wooden blocks. They should be placed between the side mount housing.

Figure 1
Wooden blocks

2. Place the hydraulic breaker on the wooden blocks.

WARNING
The parts are heavy. Take appropriate safety cautions when handling them.
Figure 2
Hydraulic breaker on wooden blocks

3. Remove auto-lubrication kit if necessary.

Figure 3
Option, removing

1. Auto-lubrication kit

4. Remove the side bolts.


Figure 4
Side bolts, removing

1. Side bolts

5. Remove the side mount housing with a hoist.

Figure 5
Side mount housing, removing

1. Side mount housing

6. Remove the bottom and upper holder from the power unit.
Figure 6
Upper and lower holder, removing

1. Upper holder
2. Bottom holder