T S (72.5-420 kV) | “KGT- 72.5 | -KGT- 125 [~KGT- 145 | KGT- 170 (> KGT- 245 (-KGT- 300 i KGT- 362 —KGT- 420 emek ioe EMEK ELEKTRIK ENDUSTRISI A.S. TY PEE siGnaTION 72.8 KV Capacitive Voltage Transformers 123 KY Cepacttive Voliage Transformers KGT-12.5 SKGT-125 KGT-145 :KGT-170 KGT-245 KGT-300 2 KGT-362 KGT-420 4145 kV Capacttive Voltage Transformers 170 kV Capacttive Voltage Transformers, 245 KV Capacitive Voltage Transformers 300 KY Capacitive Voliage Transformers 362 KV Capacitive Voltage Transformers 420 kV Capacitive Voltage Transformers D ATA... TO MAKE AN OFFER + Number of Windings DESCRIPTION Production EMEK capactive voltage transformers are manufactured in Ankara Turkey Special Design Non standard core data. creepage, seismic, etc. designs are available on request. Standards All transformers are subjected to full routine tests as described in the relevant standards. Type tests can also be performed in our own testing laboratories but should be negotiated during the order stage. Quality Assurance Emek is 1SO 9001 certified by both BVQI, Bureau Veritas Quality international and TSE, Turkish Standards Institute * Accuracy Class for Each Winding + Standards + Rated Capacitance + Voltage Rating Factor General Electrical Data * Quantity + Insulation Level + Delivory Timo + Frequency + Destination + Service Condi + Voltage Ratio + Others Frequency: 50 Hz, 60 Hz Rated Secondary Voltage: 110!\3, 10013 V ete. in conformity with customer requirement. Rated Tertiary Voltage: 110/V/3, 100/V3, 110/3, 1400/3, 100, 110 V etc. in conformity with customer requirement, Highest System Voltage: Highest system voltage from 72.5 to 420 KV. Number of Secondary Windings: In conformity with customer requirements. Maximum 4 secondary windings Voltage factor: 1.2 x Un continuous / 1.9 x Un for 30 sec, Standards: IEC, BS, ANSI, AS, other standards on request, Hermetic Seal: Oil volume variations are compensated with teflon bellows placed in the Capacitive parts. With this facility there will be no Coniact between airand oll. The dielectric strength will remain unchanged for the life time of the CVT. Primary Terminals: Primary terminals are made from tin plated brass. Vertical end horizontal primary terminals are available. Nema pad or clamp type primary terminals are avaliable on request Name Plate: Name plates are stainless steal and weatherproof. + Rated Burden for Each Winding * Creepage Distance eo External Binding Elements: All external bolts, nuts, washers etc. are either stainless steel or hot dip galvanised steel. Paintin, Enteral surface of the transformers are. corrosion free and painted with grey colour (optional). Earthquake Design: Standard design is Up to 0.80, Mechanical Strength: Applied load to the primary terminal in horizontal and vertical ia in conformity with IEC 186 Ambient Temperature: ‘Standard design is suitable for temperature range -25 C to +400. Other ranges on request. Altitude: ‘Standard design js suitable up to 1000 m above sea level. values on request, igher Garrier Accessories: If advised at order stage provision can be provided to mount line ‘raps. Tuning: The CVT is tuned in the factory and sealed, No further tuning on site is required. Bracelet: Al| bracelets used on transformers are made from aluminium alloy. Optional Accessories: + Steel Support structure * Primary connectors + Marshalling Dox LARA CTERTS TH DESIGN Storage itis recommended to store the transformers in their factory Packed condition prior to instalation, Packing The transformers are packed in rugged wooden crates which are suitable for transportation. The transformers are encapsulated in polyethylene covers to keep them from environmental effects such as rain-fall, dust and sand ete. (during transport and storage). Wooden crates can be lifted by either a fork lift or by a crane with slings. Spare Part There are no user serviceable parts, therefore no spate parts are required, Maintenance Maintenance free, simple recommendations : ‘AComplete and thorough inspection should be carried out in every year Clean the porcelain bushing at regular intervals depending on the degree of pollution, Ensure that there is no oll leakage. Periodical maasurement of capacitance and power factor are recommended. Special Tools No special tools are required for the maintenance. CAPACITIVE ssa? «AON Description ‘The capacitor stacks in Emek CVT's are the mixed type which means paper and plastic flm are used together as the dielectric. Capacitor elements are stacked and bound together to maintain constant pressure, The electrodes are made from soft rolled aluminium il Insulation The insulating oil is synthetic oll called PXE, Before impregnation, moisture and cases are removed from the oil by special process. Oil impregnation Heat and vacuurn are epplied after assembly of the capacitive unit for drying purposes, followed immediately dy ol impregnation procedure Bushings. Capacitor stacks are housed in porcelain bushings. One single bushing is used fer votage level 725-170 kV and mult bushings are used for voltage ‘evel 245-420 kV. Bushings are brown glazed porcelain, Other colours and extra high creepaue distence are available on request. MAGNETIC IU NIT Description ‘The hot dip galvanised steel tank houses the oll impregnated magnetic unit Paper Insulation il impregnated paper, high dislectric strength, low dielectric losses. Core High quality sheet steel cores are used. Oil Insulation The insulating ol is mineral clin conformity with IEC 296. Before impregnation, moisture and gases are removed from the ol by special processes. Drain plug for taking sempies and oll refling facities are provided on request. Foeting type ol evel indicators standard supply, Oil Impregnation Heat and vacuum are applied to the full insulated windings after assembly of the magnetic unit for drying purposes, followed immediately by ol impregnation procedure. Accessories Fixing holes, lifting holes, secondary terminal box, name plate and warning pletes are also provided in our standard design. ‘Secondary Terminal Box Hinged iype boxes are used and are sealable on request. ‘Secondary box consists of secondary terminals, spark gap, earthing switch, drain col, lew voltage terminal and @arthing terminal. ‘Secondary terminals are clamp type, other types are also available on request Fuses or MCB'S are also availab'e on request. Tank ‘Tank is made from hot dip galvanised ste! and painted with grey colour (optional) ‘The magnatic unit consists of the reactor (inductance coil), short orcuit protection device, anti ferro resonance filter and intermediate transformer. Primary Windings Enamelled electrolytic copper wire is used for primary Windings of intermadiate voltage transformer. Secondary Windings Enarnelled atectrolytic Copper wire is used for secondary ‘windings of intermediate Vollage transfomer TRANSPORTATION HANDLING Transportation is only possible in the upright (vertical) position, The CVT should ever be transported or stored in horizontal position. The crates should not put on top. of each other. Attention should be paid to the red "UP* arrows on the crate. For transformers which have been transported andior stored in horizontal position for any reason, factory level ro- Conditioning and testing 's necessary. The vehicle used tor transportation must be of adequate size. The packing must be tightly secured to the chassis of the transportation vehicle Ifunpaved and rough roads are to be travelled, care should be given to prevent rigorous vibration, Prolonged and rough vibration may lead to ail disturbances. Note that both magnetic and capacitor CORRECT Lnits are packed in a single wooden crates. ASSEMBLY ———s1 Before the assembly, following visual checxs should be made. ‘There are no oil leaks ‘The porcelain is not damaged There is no damage on the primary terminals The oll lovel indicator indicates sufiicent oll level Lifting holes are provided on the stee! tank. These should be used for iting end assembly. ‘The capacitor voltage transformer KGT-245, KGT- 300, KGT-362, KGT-420 cor 1 magnet Unif'and multi capacitor Uni ‘The capacitor voltage transformer KGT-72.5, KGT-125, KGT-145, KGT-170 consists of or mmagnetcunit and one capector unt. rend 2). Number of capacitor units depends on system. vollage, cieepage distance and rated capactance values. ‘The transformer is delivered in parts, This enables easy handling, vertical transportation and simple assembly on sits. ‘The paris named as{Tlandlere assembled by EMEK, Since all units are faciory sealed and must notbe opaned. The bolts and nuts are also supplied for the assembly of unit Do not loosen the red painted nuts The terminal of LV capacitor named LVT-A must be grounded or connected to the HF carrier accessories. This terminal should never be open. ava MAX INCLINATION WRONG. MAIN FEATURES OF “yO ; tA GE : The CVT consist of a capacitor stack(s) enclosed in @ porcelain bushing (s) and an inductive unit enclosed in a steel tank. The two units are independent and joined in the factory. These units should not be separated by the user. ‘The CVT is tuned in the factory. No site tuning is necessary for ratio and phase angle errors. In the capacitive divider, for 170 kV CVT, there are about 100 capacitors stacks. The line to ground voltage is 87 kV, therefore each stack is under 0.87 KV voltage stress. This voltage is small, therefore the capacitor stacks have very long life expectancy. An intermediate voltage of about 17 KV is taken from the taps in the capacitive divider and this voltage is then applied to the electromagnetic unit. In the electromagnetic unit this voltage is further reduced down to the rated secondary voltage, such as 0.1 kV. The electromagnetic unit runs at 15 kV. At this voltage level , there is no high stress and therefore the life of the electromagnetic unit is very long. The inductive unit is fitted with a damping device to reduce the transient times during a ‘short circuit on the secondary terminals. Built in short circuit device. There will be no permanent damage to the CVT in the event of a short circuit on the secondary terminals lasting up to 1 hour. All EMEK CVT's are fitted with a drain coll of 50 mH with a knife switch to short this coil if required. Therefore all EMEK CVT's can be used as simple voltage transformers by shorting this coil or can be used as voltage transformers and coupling capacitors by not shorting this coil. This feature allows flexibility in reducing stock spares to a minimum and easy movement of CVT's around in case of emergency need. Built in anti ferro resonance filter. The ferro resonance phenomena is suppressed rapidly with this anti ferro resonance filter. Emek CV7's can be equipped with DDF terminal to measure tand values if specified during the order stage. Line traps can be mounted on the top of the capacitive voltage transformer or coupling capacitor. Weight of the line trap and mounting arrangement should be given during order stage. CROSS SECTIO CAPACITIV! 5 WEA LU Cc, C2 OLTAGE TRANSFORMER Et erminal PTFE (Teflon) bellows —* Special capacitor oll —* Capacitor elements IU Porcelain bushing Primary Terminal : High Voltage Capacitance Low Voltage Capacitance Reactor (Induciance Call) Intermeciate Transiormer : Shot Circuit Protection Device ‘Anti-ferroresonance Filter © Secondary Terminals Drain Coil Earthing Switch Spark Gap Low Voltage Terminal - HF Terminal + Earthing Terminal LV insulator | Oil Filling Tap Oil Level Indicator Oil Sampling Valve DATA, cs PACKING DETIALS (Approximate values) Weight Dimesion (cm) pe [ram [cea re _| KGT-72.5 KGT-125 KGT-145 700 KGT-170 750 KGT-245 1200 KGT-300 1300 KGT-362 +600 KGT-420 4600 Description Kar725 25 | xar-145 | kat-170 | Ker-zas | Kor:200 | Ker-a62 | kor-«20 Highest System Voltage 72.5, 13 145, 470. 245 | 300 362 420 ated Frequoncy ie 60 or 60 | Rated primary Voltage KV from 60 KV upto 400 KV | Rated Secondary Vatage | _V 100N3, 110/V3, 1003, 106, 110 ei6, Rated Capaciance() | pF | 8000 | 6000 | 4500 | 4800 | 7000 | sooo [#500] s000 Test Voltages ‘kv_| s40re25 | 2s0i560 | 27sies0 | 25760 | asori050 | st071175 | 57071300 | eania25 Rated Votage Factor a 1.2 Un Gontinuousit 9x Un for 30 seo Creenane cisaree™) | mm) 1450 | 2460 [ 2900 | 2400 | 4000 | 6000] ves] e400 Dimensions A am | - a 5 5 aay | 1420 | 1620 ia20 | mm| 00 | i800 | 1300 | ioos | 1420 | 1420 | 1620 | 1820 C | mm | sasis20 | 645/520 | e45i520 | sasis20 | éasise0 | exsi620 | eaais20 | A550 (() Other capacitance values ars ago avallabie on request. ("Higher creopage distance are also available on request. inet The technical data and dimansione provided in this document are for illustrative intentions only. The exact data and dimensions can be verified once the client's finel specs are known. Furthermore as efforts are constantly made to improve design and methods of manufacture, the equipment offered may aiffer from the equipment descrived in this document, EMEK ELEKTRIK ENDUSTRISi A.S. Post Address: P.O Box 648, Ulus 06044, Ankara Turkey Factory Address : Esenboga Yolu 23 Km Cubuk Ankara Turkey Phone + 90312 3980795 398 07 96 398 05 05 Fax +90312 398.07 58 e-mail emekeeas@ada net tr web site www.emek.com.tr September, 2001

You might also like