Professional Documents
Culture Documents
Air Quality Monitors 2S & 5S - Product Catalogue 241022
Air Quality Monitors 2S & 5S - Product Catalogue 241022
5S & 2S Models
PRODUCT CATALOGUE
www.envirosuite.com
Table of contents
About Envirosuite..................................................................................................................... 4
Environmental intelligence solutions................................................................................ 6
Air Quality Monitor 5S............................................................................................................. 8
Air Quality Monitor 2S............................................................................................................. 10
Smart gas cartridges.............................................................................................................. 13
What we do different.............................................................................................................. 14
Evidences of accuracy........................................................................................................... 15
Pollutants
Carbon Monoxide................................................................................................................ 17
Carbon Dioxide..................................................................................................................... 18
Sulphur Dioxide..................................................................................................................... 19
Nitric Oxide............................................................................................................................ 20
Volatile Organic Compounds............................................................................................ 21
Ammonia................................................................................................................................ 22
Nitrogen Dioxide................................................................................................................... 23
Particulate Matter................................................................................................................ 24
Technical specs........................................................................................................................ 28
Power packs.............................................................................................................................. 30
Installation process................................................................................................................. 31
www.envirosuite.com 02 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 03 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Envirosuite is the world’s most Our Purpose Our Vision Our Mission
SCIENCE BUILT-IN
An advanced environmental
BUILT FOR TODAY WITH
intelligence portfolio that embeds
TOMORROW'S OUTCOMES
decades of science, innovation
through expertise and complex IN MIND
EVS Omnis
ABOR ATE
modelling, all made simple for users.
C O LL Optimise operational
Powerful software built outcomes, increase production,
COMMITMENT TO CUSTOMERS make tangible cost savings and
We put customers at the heart
for industrial facilities to build social licence to operate
of what we do to build long- Collaborating with act on emissions, plan with surrounding communities.
lasting, trusted relationships and industry, regulators for operational risks and
expand this to our partners and and communities RAPID RESPONSE AND
engage with stakeholders.
IN
IC
NO
ST
environmental
Easy-to-use, location-specific
O
VAT
HUMAN INGENUITY,
AGN
ENVIRONMENTAL partnering with and provide secure, public portals to educate and
a variety of science-based EVS Water engage with communities
ION
TECHNOLOGY technologies to environmental and stakeholders, including
Our global team is made up of give our customers intelligence software observation submissions to
talented, passionate domain experts flexibility and choice. and IoT platforms. Digital twin technology for
foster transparent two-way
who are driven by a collective water treatment powered communication.
purpose and empowered to offer
by machine learning and
their unique contribution everyday. UNLOCK VALUE BEYOND
Domain Our customers deterministic modelling.
knowledge and are empowered to COMPLIANCE
ESG ENABLING, expertise across monitor, predict
SDG ADVANCING air, dust, odour, and mitigate their Harness predictive insights
Society demands measurable, noise, vibration operational impact. from the environmental
sustainable performance. Our and water. monitoring network to avoid
EX
technology supports ESG criteria EVS Aviation unwanted impacts and keep
RT
PE
production moving.
RE
www.envirosuite.com 04 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 05 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Environmental
intelligence 24/7 Proactive air
solutions quality management
EVS Omnis is a cloud-based solution that enables
operators to integrate environmental intelligence
into day-to-day operations to mitigate risk, impro-
ve operational safety and keep production moving.
Powered by Kunak, our hyperlocal air quality mo-
nitors are designed to collect real-time information
across multiple parameters. Data feeds directly
into our EVS Omnis platform and is combined with
Envirosuite’s proprietary algorithms to provide
actionable insights for users to proactively manage
site-generated emissions at their operations.
www.envirosuite.com 06 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 07 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Air Quality Monitor 5S Optical particle counter
Solar shield
Built-in sensors
Specifications
Easy & Fast Cartridges Proven Dimensions 257 x 270 x 225 mm Gas sensors CO, CO2, NO, NO2, O3, SO2, H2S, NH3 & VOCs
installation system accuracy
Weight <3.5 kg PM sensor PM1, PM2.5, PM4, PM10 TSP and TPC
Set up in less than 10 minutes Replace and combine pollutant Proven as the best-in-class Enclosure
PMMA & Polycarbonate &
Internal status
Temperature | Battery | Charging voltage &
with visual diagnosis in a built- sensors with a plug & play system by independent Stainless steel current | Signal
in display. system. organizations. Operating temp -20 ºC to 60ºC Temperature | Humidity | Atmospheric pres-
Built-in sensors
sure | Dew point
Operating RH 0 to 99 %RH
Sampling freq. 3Hz gases, 0.25Hz particles
IP rating IP65
Avg. periods From 10 seconds to a maximum of 24 hours
EVS Omnis Easy to use Multi Battery Lithium 2.9Ah or 26 Ah
Sending periods From 5 minutes to a maximum of 24 hours
platform software pollutant External supply
7 - 12 Vdc. charger or solar
panel Remote Bidirectional communications. Remote confi-
Visualise, analyse and manage management guration and calibration
EVS Omnis can be Measure up to 5 gases and Autonomy 24/7 with charger or solar panel
your data in the cloud. used by specialists and particulate matter at once. SIM Embedded eSIM and SIM holder
0.08 - 1.2W (depending on
non-specialists. Power consumption
configuration)
www.envirosuite.com 08 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 09 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Air Quality Monitor 2S
Built-in sensors
Solar shield
IP65 protection
A compact air quality station Smart gas
for hyperlocal monitoring cartridges
Main applications:
• Wastewater management
• Landfill monitoring
Specifications
Gas sensors CO, CO2, NO, NO2, O3, SO2, H2S, NH3 & VOCs
Dimensions 200 x 153 x 185 mm
www.envirosuite.com 10 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 11 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Smart gas cartridges
Description
Both air quality monitors are sensor-based devices equipped with slots to insert smart gas cartridges.
Smart gas cartridges solve many of the known issues of sensor technology: sensor variability, factory and
field calibration, automatic data invalidation, sensor replacement, network operation and maintenance
work.
Smart gas cartridges ensure measurement control throughout the life cycle of each sensor, making both air
quality monitors more sustainable and our customers' lifes easier.
Each cartridge is cali- Combine the parameters Simply take the old one The electronic and me-
brated and validated in- freely. Reuse and scale out and replace easily chanical parts can be
dividually in lab against your basestations at with the new one, on reused, making it the
traceable reference your own pace. field. Be back online in most sustainable AQ
standards. 2'. sensor- based station in
the market.
www.envirosuite.com 12 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 13 | Product Catalogue: Air Quality Monitor 5S & 2S Models
What we do different Evidence of Accuracy
We continuously conduct intercomparative studies with reference stations in different locations and labo-
Quality Control & Quality Assurance cycle ratories to guarantee the highest quality results.
Sensor 01. Sensors are factory assessed to ensure the R2 RL MAE U(exp) % R2 RL MAE U(exp) %
selection good operation of each sensor. CO 0.95 Y=1.01*X - 26.89 41.6 10.22
NO 0.95 Y=0.98*X - 0.25 2.16 7.28
STOCKHOLM, SWEDEN
MEXICO CITY, MEXICO
tronics are characterized under specific
environmental conditions
LABORATORY
against Kunak gold standards correctly
maintained with reference AQMS. Kunak
algorithm uses the reference data for vali-
FIELD
BARCELONA, SPAIN
Cartridges 06. Once the sensor arrives to its end of life,
MANCHESTER, UK
validation cartridges are returned to Envirosuite
and the electronics are recycled for new
cartridges.
ANTWERP, BELGIUM
ANTWERP, BELGIUM
An algorithm corrects the interferences and ar- • Not dependant on nearby stations.
tifacts typically found in raw data, compensating
environmental effects like temperature, humidity
and pressure (depending on the cartridge), as well
as cross-sensitivities using onboard data.
Remote calibration of a linear response Air Quality Monitor 5S Air Quality Monitor 5S
Reference station Reference station
For most of the cartridges temperature, humidity and crosssensitivities effects have a nonlinear response
in the sensor raw data which are corrected by an algorithm converting the nonlinear response into a linear
response.
The most acurrate multi-pollutant sensor
Gas Particulate matter
Mass Factor
correction
Sp
Raw
data
Kunak PM correc- “It provides excellent quality for PM1, “Sensor nodes have very small form “The three sensors showed an absolute
Zero
value
correction ted data
very good quality for PM2.5, PM10, and factor and weight that are practical intra-model variability of 0.32 ppb, 0.33
O3, and good quality for NO2 and NO, for response field deployments.” ppb and 0.002 ppm for O3, NO2 and CO
being the best performing sensor for measurements, respectively.”
this latter pollutant.”
www.envirosuite.com 14 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 15 | Product Catalogue: Air Quality Monitor 5S & 2S Models
CO
Carbon
monoxide
CO cartridge
(A) K-CO-A-01 / (B) K-CO-B-01
The Carbon Monoxide Cartridge has a built-in electrochemical sensor with very
low noise electronics allowing the measurement from very low concentrations
(ppb) up to several ppm. To cover different applications, there are two measu-
rement ranges: Type A measuring most common concentrations range, and
Type B, a higher range version that can measure up to 500 ppm, decreasing
the accuracy at low concentrations.
This cartridge is very stable over time with a lifespan that can go beyond the
specification for several months under no extreme environments.
information on
Limit of Detection (LOD)(7)
0.02 ppm(B)
µg/m³, ppb(A)
Unit of measurement 20 ppb(A)
mg/m³, ppm(B) Repeatability(8)
0.05 ppm(B)
0 - 12,000 ppb(A)
emissions
Measurement range(1) < 30 sec(A)
0 - 500 ppm(B) Response time(9)
< 180 sec(B)
1 ppb(A)
Resolution(2) ± 80 ppb(A)
0.01 ppm(B) Typical accuracy (MAE)(10)
± 0.1 ppm(B)
Operating temperature range(3) -30 to 50 ºC
Typical precision R² (10) > 0.85
Operating RH range(4) 0 to 99 %RH
Typical slope(10) 0.78 - 1.29
Recommended RH range(4) 15 to 90 %RH
-50 ppb ≤ a ≤ +50 ppb(A)
Typical intercept (a)(10)
Operating life(5) > 24 months -0.1 ppm ≤ a ≤ +0.1 ppm(B)
Guarantee range(6) 1,000 ppm DQO - Typical U(exp)(11) < 20%
< 3 ppb(A)
Typical Intra-model variability(12)
< 0.05 ppm(B)
www.envirosuite.com 16 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 17 | Product Catalogue: Air Quality Monitor 5S & 2S Models
CO2 NO
Carbon Nitric
dioxide oxide
Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
CO2 is a result of normal cell function when it is It’s difficult to achieve situational awareness of Nitrogen oxide is emitted from automotive engines The EVS Omnis platform can be used by specialist
breathed out of the body. Besides, it is an essential Carbon Dioxide (CO2) levels and know when you and the burning of coal, oil, diesel fuel, and natural and non-specialists to proactively manage air quality
element in photosynthesis, the process by which are operating within thresholds with a traditional air gas, specially from electric power plants. It is also emissions such as Nitric Oxide (N0). Users are em-
plants make food and energy. Levels of atmospheric quality monitoring system. emitted by cigarettes, gas stoves, wood burning, powered with actionable insights to mitigate pro-
CO2 have increased since the Industrial Revolution. and silos that contain silage. blematic N0 emissions with powerful visualisation,
EVS Omnis empowers your operation with actiona-
The primary causes are deforestation and the bur- analytics, prediction and reporting.
ble insights to proactively manage CO2 emissions at
ning of fossil fuels such as coal, for electricity, heat
a site-level.
production and for transportation (cars, ships, pla-
nes, etc.). It could also be formed, as a secondary
pollutant, by CO oxidation.
The Carbon Dioxide Cartridge has a built-in non-dispersive infrared sensor The Nitric Oxide Cartridge has a built-in electrochemical sensor ideal to mea-
(NDIR) ideal to measure from low to high concentrations that can be found in sure from very low ppb concentrations up to several ppm than can be found in
the atmosphere. Besides, it includes an automatic baseline calibration to main- the atmosphere close to pollution sources (vehicles, industries…). This cartrid-
tain the long-term stability with no effect of humidity, temperature and pressu- ge is very accurate and stable with very good temperature correction algorithm
re, which are corrected in the algorithm. and can work beyond two years easily under no extreme environments. The
cartridge can suffer from a small zero drift (some ppbs) over time thatcan be
easily corrected with a remote calibration tool.
Type NDIR Response time(9) < 30 sec Type Electrochemical Limit of Detection (LOD)(7) 2 ppb
Unit of measurement mg/m³, ppm Typical accuracy (MAE) (10)
± 30 ppm Unit of measurement µg/m³, ppb Repeatability (8)
4 ppb
Measurement range (1)
0 - 5,000 ppm Measurement range (1)
0 - 5,000 ppb Response time (9)
< 30 sec
Resolution (2)
1 ppm Resolution(2)
1 ppb Typical accuracy (MAE) (10)
± 4 ppb
Operating temperature range (3)
-20 to 50 ºC Operating temperature range (3)
-30 to 40 ºC Typical precision R² (10)
> 0.9
Operating RH range (4)
0 to 99 %RH Operating RH range (4)
0 to 99 %RH Typical slope (10)
0.9 - 1.12
Recommended RH range (4)
15 to 95 %RH Recommended RH range (4)
15 to 85 %RH Typical intercept (a) (10)
-2 ppb ≤ a ≤ +2 ppb
Operating life (5)
> 7 years Operating life (5)
> 24 months DQO - Typical U(exp) (11)
< 20%
Guarantee range (6)
20 ppm Typical Intra-model variability (12)
< 1 ppb
www.envirosuite.com 18 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 19 | Product Catalogue: Air Quality Monitor 5S & 2S Models
NO2 O3
Nitrogen Ozone
dioxide
Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
The major source of NO2 is combustion of fossil Managing Nitric Dioxide (NO2) emissions requires a Ozone (O3) is found in the troposphere and it is the The EVS Omnis platform offers a proactive air
fuels: coal, oil and gas. Most of the NO2 in cities is bird's eye view of real-time monitoring data, local result of the atmospheric reaction of a number of quality management solution for parameters such
derived from motor vehicle’s exhausts. Other sour- weather conditions and accurate insights on what's precursor pollutants, which come from both natural as Ozone (O3) emissions. The cloud-based sof-
ces of NO2 are petrol and metal refining, electricity next. The EVS Omnis platform empowers your ope- and man-made sources. Precursor pollutants are tware is designed to empower your operation with
generation from coal-fired power stations, other ration with actionable insights through data capture originated by human activities and include hy- actionable insights through powerful visualisation,
manufacturing industries and food processing. from air quality monitoring devices, visualisation, drocarbons and nitrogen oxides. They are largely analytics, prediction and reporting.
analytics, prediction and reporting. emitted by cars and other vehicles, fossil fuel power
No other platforms offer the same level of scientific
plants, oil refineries, the agriculture sector and a
and technological excellence in such a user-friend-
number of other industries.
ly, practical form to benefit ambient air quality
monitoring programs.
The Nitrogen Dioxide Cartridge has a built-in electrochemical sensor which has The Ozone cartridge has a built-in electrochemical sensor that detects NO2
no interference with Ozone thanks to its embedded O3 filter, making the cartri- and O3 concentration. Then, to measure accurately the O3 concentration, it is
dge ideal to measure the concentrations found in the atmosphere, from very low required to have installed in the same device the NO2 Cartridge. Thus, thanks
levels in clean environments to high concentrations in polluted areas of cities or to an algorithm, it is possible to deliver accurate measurements of Ozone, with
industries. However, the cartridge can be affected by fast humidity transients no NO2 influence, even at high temperature which are related to higher O3 con-
reducing its accuracy during these events. centration due to the sun radiation.
www.envirosuite.com 20 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 21 | Product Catalogue: Air Quality Monitor 5S & 2S Models
H2S SO2
Hydrogen Sulphur
sulfide dioxide
Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
Most of this gas present in the atmosphere has EVS Omnis software gives you the tools to mana- Sulfur Dioxide (SO2) is invisible and has a nas- Knowing when you are operating within Suphur
natural origin by the organic matter decomposi- ge Hydrogen Sulfide (H2S) quickly and efficiently: ty smell. It is produced by the combustion of any Dioxide (S02) thresholds limits can be the difference
tion. Anthropically, it occurs in processes in which real-time monitoring, advanced analytics emissions substance that contains sulfur. The main source between staying operational and shutting down.
sulphur compounds and organic matter are invol- modelling, and effective community complaints ma- of SO2 in the atmosphere comes from combus-
EVS Omnis can visualise real-time S02 emission
ved at high temperatures. Some industrial activities nagement are all easily accessible on our intuitive tion of coal or fossil fuels while small sources are
levels, when you run the risk of exceedance and
that emit this gas are paper pulp manufacturing, platforms. in metallurgy and naturally by volcanic eruptions.
exactly where you should focus mitigation efforts.
oil refining, water treatment plants and the viscose Locomotives, ships and other vehicles that burn
Smart alerting from your environmental monitoring
manufacturing textile industry. fuel with a high sulfur content are other emission
network to know when to boost production during
source. Besides, it can react with other compounds
safe times and when to schedule other activities.
in the atmosphere contributing to particulate matter
pollution.
H2S cartridge
(A) K-H2S-A-01 / (B) K-H2S-B-01
The Hydrogen Sulfide cartridge has a built-in electrochemical sensor very SO2 cartridge
sensitive to its specific pollutant allowing the sensor to detect any change in K-SO2-A-01
H2S concentrations. This cartridge responds and detects Methyl Mercaptan
(CH4S). To cover different applications, there are 2 measurement ranges: Type The Sulfur Dioxide Cartridge has a built-in electrochemical sensor which
A: detect low ppb concentrations in real environments. Although an algorithm presents high cross-sensitivities with O3 and NO2. When used together with
corrects well the temperature variations, it is not recommended to use this the NO2 and O3 cartridges, an algorithm is capable of correcting from these
cartridge to detect levels below 10 ppb. cross-sensitivities improving the accuracy of the measurements. However, it
is not recommended for outdoors application requiring accurate SO2 measure-
Type B: a higher range version that can measure up to 20 ppm, decreasing the ments at very low concentrations (<20 ppb).
accuracy at low concentrations.
www.envirosuite.com 22 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 23 | Product Catalogue: Air Quality Monitor 5S & 2S Models
NH3 VOCs
Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
Ammonia (NH3) is a colourless gas with a pungent The EVS Omnis platform can be used by specia- Volatile Organic Compounds (VOCs) can be produ- EVS Omnis can visualise real-time VOC emission
odour that can be detected by humans at 0.4-1 list and non-specialists to proactively manage air ced by fuel combustion (wood, coal, gasoline etc.) levels and alert of you of when you run the risk of
ppm, being the exposure limit 50 ppm. NH3 is origi- quality emissions such as Ammonia (NH3). Users are such as mobile sources and industries. They can be exceedance. Predictive modelling combined with
nated from both natural and anthropogenic sources, empowered with actionable insights to mitigate pro- released to the atmosphere due to gasoline, paint, hyperlocal weather forecasts can let you know
being the main source agriculture (fertiliser applica- blematic NH3 emissions with powerful visualisation, and solvents evaporation from above ground stora- exactly where you should focus mitigation efforts
tion and fabrication) and live- analytics, prediction and reporting. ge tanks. Another of the most important emission while enabling you to plan for periods of high risk.
stock (manure management), followed by the waste sources is biogenic, by vegetation natural release.
and water management (slurries, composting and
landfills). Other sources are household and indus-
trial cleaners, that can affect directly to humans
exposed to them. VOCs cartridge
(A) K-VOCs-A-01 / (B) K-VOCs-B-01
Technical specifications
Technical specifications Limit of Detection (LOD)(7)
1 ppb (A)
Type Photoionization detector 0.01 ppm (B)
Type Electrochemical Limit of Detection (LOD)(7) 0.1 ppm µg/m³, ppb (A) 5 ppb (A)
Unit of measurement Repeatability(8)
mg/m³, ppm (B) 0.02 ppm (B)
Unit of measurement mg/m³, ppm Response time(9) < 45 sec
0 - 3,000 ppb (A) < 12 sec (A)
Measurement range(1) 0 - 50 ppm Typical accuracy (MAE)(10) ± 0.3 ppm Measurement range(1) Response time(9)
0 - 40 ppm (B) < 10 sec (B)
Resolution(2) 0.01 ppm Typical Intra-model variability(12) < 0.1 ppm
1 ppb (A) ± 10 ppb (A)
Resolution(2) Typical accuracy (MAE)(10)
Operating temperature range(3) -10 to 50 ºC 0.01 ppm (B) ± 0.1 ppm (B)
Operating RH range(4) 0 to 99 %RH Operating temperature range(3) -40 to 60 ºC Typical precision R² (10) > 0.99
Recommended RH range(4) 15 to 90 %RH Operating RH range(4) 0 to 99 %RH Typical slope (10)
0.99 - 1.002
Operating life(5) > 24 months Recommended RH range(4) 0 to 99 %RH -9 ppb ≤ a ≤ +9 ppb (A)
Typical intercept (a)(10)
Operating life(5) 10,000 hours -0.08 ppm ≤ a ≤ +0.08 ppm(B)
Guarantee range(6) 100 ppm
Typical Intra-model < 3 ppb (A)
50 ppm (A)
Guarantee range(6) variability(12) < 0.1 ppm (B)
60 ppm (B)
www.envirosuite.com 24 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 25 | Product Catalogue: Air Quality Monitor 5S & 2S Models
PM1
PM2.5
PM4
Particulate PM10
TSP
Matter TPC
Non-dispersive
Photo-ionization
Type Electro-chemical infrared Electro-chemical Electro-chemical Electro-chemical Electro-chemical Electro-chemical Electro-chemical
detector Optical particle Optical particle Optical particle Optical particle Optical particle Optical particle
(NDIR) Type
counter counter counter counter counter counter
Unit of µg/m³, ppb (A) µg/m³, ppb (A) µg/m³, ppb (A)
mg/m³, ppm µg/m³, ppb µg/m³, ppb µg/m³, ppb µg/m³, ppb mg/m³, ppm
measurement Unit of
mg/m³, ppm (B) mg/m³, ppm (B) mg/m³, ppm (B) µg/m³ µg/m³ µg/m³ (A) µg/m³ (A) µg/m³ (A) counts/cm³ (A)
measurement
0 - 12,000
Measurement 0 - 2,000 ppb (A) 0 - 3,000 ppb (A)
ppb (A) 0-5,000 ppm 0-5,000 ppb 0-5,000 ppb 0-2,000 ppb 0-10,000 ppb 0-50 ppm
range (1) Measurement 0 - 10,000
0 - 20 ppm (B) 0 - 40 ppm (B) 0 - 1,000 µg/m³ 0 - 1,500 µg/m³ (A) 0 - 1,500 µg/m³ (A) 0 - 2,500 µg/m³ (A) 0 - 3,000 µg/m³ (A)
0 - 500 ppm (B) range (1) counts/cm³ (A)
1 ppb (A) 1 ppb (A) 1 ppb (A)
Resolution (2) 1 ppm 1 ppb 1 ppb 1 ppb 1 ppb 0.01 ppm
0.01 ppm (B) 0.01 ppm (B) 0.01 ppm (B) Resolution (2) 1 µg/m³ 1 µg/m³ 1 µg/m³ (A) 1 µg/m³ 1 µg/m³ (A) 1 counts /cm³ (A)
Operating temp.
-30 to 50 ºC -20 to 50 ºC -30 to 40 ºC -30 to 40 ºC -30 to 40 ºC -30 to 50 ºC -30 to 40 ºC -10 to 50 ºC -40 to 60 ºC Operating
range (3)
-10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A)
temp. range (3)
Operating RH
0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99% RH Operating
range (4)
0 to 99 %RH 0 to 99 %RH 0 to 99 %RH (A) 0 to 99 %RH 0 to 99 %RH (A) 0 to 99 %RH (A)
RH range (4)
Recommended
15 to 90 %RH 15 to 95 %RH 15 to 85 %RH 15 to 85 %RH 15 to 85 %RH 15 to 90 %RH 15 to 90 %RH 15 to 90 %RH 0 to 99% RH Recommended
RH range (4)
0 to 95 %RH(A) 0 to 95 %RH (A) 0 to 95 %RH (A) 0 to 95 %RH 0 to 95 %RH (A) 0 to 95 %RH (A)
RH range (4)
Operating life (5) > 24 months > 7 years > 24 months > 24 months > 24 months > 24 months > 24 months > 24 months 10,000 hours Operating
> 24 months > 24 months > 24 months (A) > 24 months > 24 months (A) > 24 months (A)
life (5)
20 ppb (A)
4 ppb (A)
5 ppb (A)
Typical precision
> 0.85 - > 0.9 > 0.85 > 0.9 > 0.8 > 0.7 - > 0.99 Typical
- R² (10)
0.85 - 1.18 (A) 0.85 - 1.18 (A) 0.85 - 1.18 (A) 0.85 - 1.18 (A) 0.85 - 1.18 (A) -
Slope (10)
Typical Slope (10) 0.78 - 1.29 - 0.9 - 1.12 0.78 - 1.29 0.85 - 1.18 0.78 - 1.29 0.78 - 1.29 - 0.99 - 1.002 Typical -1.8 µg/m³ ≤ a -2 µg/m³ ≤ a ≤ -2 µg/m³ ≤ a ≤ -3 µg/m³ ≤ a ≤ -4 µg/m³ ≤ a ≤
-
Intercept (a) (10) ≤ +1.8 µg/m³ (A) +2 µg/m³ (A) +2 µg/m³ (A) +3 µg/m³ (A) +4 µg/m³ (A)
-50 ppb ≤ a -2 ppb ≤ a -9 ppb ≤ a
Typical Intercept ≤ +50 ppb (A) -2 ppb ≤ a -4 ppb ≤ a -3 ppb ≤ a ≤ +2 ppb (A) -5 ppb ≤ a ≤ +9 ppb (A) DQO - Typical
- - < 50% (A) < 50% (A) < 50% (A) < 50% (A) < 50% (A) -
(a) (10) U(exp) (11)
-0.1 ppm ≤ a ≤ +2 ppb ≤ +4 ppb ≤ +3 ppb -0.02 ppm ≤ a ≤ +5 ppb -0.08 ppm ≤ a
≤ +0.1 ppm (B) ≤ +0.02 ppm (B) ≤ +0.08 ppm (B) Typical intra-model
< 2 µg/m³ (A) < 2 µg/m³ (A) < 2 µg/m³ (A) < 2 µg/m³ (A) < 2 µg/m³ (A) -
variability (12)
DQO - Typical
< 20% - < 20% < 25% < 20% NA < 25% NA NA
U(exp) (11)
Typical intra- < 3 ppb (A) < 2 ppb (A) < 3 ppb (A)
model variability - < 1 ppb < 1 ppb < 1 ppb < 3 ppb < 0.1 ppm
(12)
< 0.05 ppm (B)
< 0.02 ppm (B)
< 0.1 ppm (B)
1. Measurement range: concentration range measured by the sensor. 8. Repeatability (measured at laboratory conditions at 20ºC and 50% RH): closeness of
the agreement between the results of successive measurements of the same measu-
2. Resolution: smallest unit of measurement that can be indicated by the sensor. re carried out under the same conditions of measurement, based on the metric from
the Technical Specification UNE CEN/TS 17660-1:2022.
3. Operating temperature range: temperature interval at which the sensor is rated to
operate safely and provide measurements. 9. Response time: time needed by the sensor to reach 90% of the final stable value.
4. Operating RH range (Recommended RH range): humidity interval at which the sensor 10. Statistical metric: statistics obtained between hourly measurements of the device
is rated to operate safely and provide measurements. and the reference instruments for 1 to 8 months field test between -10 to +30 ºC in
Recommended RH range of the sensor for continuous exposure. different countries.
5. Operating life: lifetime of the sensor at normal conditions. 11. DQO-Typical U(exp): Data Quality Objetive expressed as the Expanded Uncertainity in
the Limit Value obtained between hourly measurements of the device and the referen-
6. Guarantee range: limit covered by the guarantee. ce instruments for 1 to 8 months field test between -10 to +30ºC in different countries,
based on the metric from the European Air Quality Directive 2008/50/EC and from the
7. LOD (Limit Of Detection): measured at laboratory conditions at 20ºC and 50% RH.
Technical Specification UNE CEN/TS 17660-1:2022.
The limit of detection is the minimum concentration that can be detected as signi-
ficantly different at zero gas concentration, based on the metric from the Technical 12. Typical intra-model variability: calculated as the standard deviation of the three sen-
Specification UNE CEN/TS 17660-1:2022. sor means in 1 to 8 months field test between -10 to +30ºC in different countries.
www.envirosuite.com 28 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 29 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Power packs Installation process
Air Quality Monitor 5S and 2S models are equipped with a rechargeable lithium Easy & Fast
battery which prevents the equipment from shutting down due to a power cut.
In this way, they can continue working for long periods of time until the power The installation of the Air Quality Monitor 5S and 2S models is quick and easy, and the device can start to
is restored. operate in less than 20 min.
First of all, it's needed to fix the metal support on a mast or a wall. After it, the device can be held on its
support.
Once the device is mounted in its final position, turn it on and check the confirmation on the display. If you
need to replace a cartridge, just release the metal grid, unplug the cartridge and plug the new one.
Solar packs
The 6.3-volt high-efficiency monocrystalline solar panel is robust, waterproof
(IP67) and has been designed for prolonged outdoor use in any environ-
ment. The photovoltaic panel makes the device totally autonomous from the Air Quality Monitor 5S
power grid, allowing the installation anywhere without civil works or in remote
locations.
Installation Cartridge replacement
1 2 3 4
RELEASE THE
METAL GRID
K-PW-SP12W-9C-02
DEVICE SOLAR PANEL BATTERY AVG. DURATION
K-PW-SP6W-9C-02
Air Quality Monitor 5S 12 W 93 Wh (9 cell) 9 - 30 days
K-PW-SP12W-7C-01
Air Quality Monitor 2S 6W 72 Wh (7 cell) 9 - 20 days
K-PW-SP6W-7C-01
The table above shows the minimum and maximum battery life (without solar radiation) for different device configurations.
NEW
CARTRIDGE
www.envirosuite.com 30 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 31 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Envirosuite (ASX:EVS) is a global leader in environmental intelligence,
using proprietary technology and real-time localised data to help
industries and communities thrive.
www.envirosuite.com