T22021-0020-EN-R02-iTracker Family Drawings - Poggi - 230303 - 142308

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

PV module fixing and grounding method: Out of scale PV module rails Out of scale Out of scale

1134
1093 10 C130x180x40x4 C80x180x20x3 C80x180x25x3.25 C80x180x30x4
Side modules
Scale 1:1

South North

2279
y Ref. Ref. Ref. Ref.
point point point point
Bolt M6
Torque tube Large washer M6 Torque tube x
Star washer A8*
Flat washer M6 Drive Standard External Perimeter
Grower M6 Pile Pile Pile Pile
Nut M6
NOTE: small module installed on motor side - to avoid D S E P
* One star washer per PV module interference during rotation NOTE: take the pile reference point position (x,y) from the coordinates file
Out of scale
South North


-5

+4

gle
iT68x2 INT

an
Rotation range= 110°
Pag. 2

ow
St
2451
St
ow

1484
an
gle
iT54x2 EXT -4

Z=1070
+5

Z=1070
Pag. 3

523
West East

6600
z: nominal ramming quote

iT50x2 EXT
Pag. 4

iT50x2 INT
Pag. 5

iT41x2 EXT
Pag. 6

iT41x2 INT
Pag. 7

REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE


iT27x2 EXT
Pag. 8 - 










INT. DRAW. CODE:

-
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
1/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Tel. +39 0547 52600
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.2 Identification holes

180

External pile iT68x2 INT

Tube length 78765


Table length 78562
South North
6600

N° 10 External rails N° 10 External rails

Sect. A-A
Driven row 2009 6292 7436 7848 7848 7848 7848 7848 7848 7436 6292 2009
E E S S S D S S S E E
N° 10 External rails N° 10 External rails

2009 6292 7436 7848 7848 7848 7848 7848 7848 7436 6292 2009
Sect. B-B E E S S S D S S S E E
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350 REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE

= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 











= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
2/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Piles identified by shape and central hole. Tel. +39 0547 52600

Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.1 Identification hole

180

Perimeter pile
iT54x2 EXT

Tube length 62749


Table length 62546
South North
6600

All external rails

Sect. A-A
Driven row 1758 5262 5377 6292 6292 6292 6292 6292 6292 5377 5262 1758
P P P P P D P P P P P
All external rails

1758 5262 5377 6292 6292 6292 6292 6292 6292 5377 5262 1758
Sect. B-B P P P P P D P P P P P
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350
= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 









= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
3/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Tel. +39 0547 52600
Piles identified by shape and central hole.
Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.1 Identification hole

180
iT50x2 EXT
Perimeter pile

Tube length 58170


Table length 57970
South North
6600

All external rails

Sect. A-A
Driven row 1758 4919 5148 5720 5720 5720 5720 5720 5720 5148 4919 1758
P P P P P D P P P P P
All external rails

1758 4919 5148 5720 5720 5720 5720 5720 5720 5148 4919 1758
Sect. B-B P P P P P D P P P P P
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350
= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 









= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
4/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Tel. +39 0547 52600
Piles identified by shape and central hole.
Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.2 Identification holes

180

External pile
iT50x2 INT

Tube length 58170


Table length 57970
South North
6600

N° 10 External rails N° 10 External rails

Sect. A-A
Driven row 1872 5720 6521 7436 7436 7436 7436 6521 5720 1872
E E S S D S S E E
N° 10 External rails N° 10 External rails

1872 5720 6521 7436 7436 7436 7436 6521 5720 1872
Sect. B-B E E S S D S S E E
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350
= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 









= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
5/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Tel. +39 0547 52600
Piles identified by shape and central hole.
Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.1 Identification hole

180
iT41x2 EXT
Perimeter pile

Tube length 47874


Table length 47674
South North
6600

All external rails

Sect. A-A
Driven row 1816 5262 5777 5777 5777 5777 5777 5777 4462 1472
P P P P D P P P P
All external rails

1816 5262 5777 5777 5777 5777 5777 5777 4462 1472
Sect. B-B P P P P D P P P P
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350 REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE

= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 











= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
6/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Piles identified by shape and central hole. Tel. +39 0547 52600

Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.2 Identification holes

180

External pile iT41x2 INT

Tube length 47880


Table length 47674
South North
6600

N° 10 External rails N° 10 External rails

Sect. A-A
Driven row 2102 6406 7779 8122 8122 7779 5262 2102
E E S D S E E
N° 10 External rails N° 10 External rails

2102 6406 7779 8122 8122 7779 5262 2102


Sect. B-B E E S D S E E
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350
= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 









= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
7/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Tel. +39 0547 52600
Piles identified by shape and central hole.
Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico
Piles identification detail Out of scale

N.1 Identification hole

180
iT27x2 EXT
Perimeter pile

Tube length 31858


Table length 31658
South North

6600
A

All external rails

Sect. A-A
Driven row 1654 4805 4805 5137 5137 4233 4233 1654
P P P D P P P
All external rails

1654 4805 4805 5137 5137 4233 4233 1654


Sect. B-B P P P D P P P
Driving row

Torque tubes Piles


= L10133 □120x2.40 S420GD J2 + Z450 S = Standard Pile (C80x180x20x3, S355 J2 + HDG)
= L8873 □120x2.40 S420GD J2 + Z450 E = External Pile (C80x180x25x3.25, S420 J2 + HDG,
= L10051 □120x2.40 S420GD J2 + Z450 identified by n.2 central holes as per detail)
= L11132 □120x2.60 S420GD J2 + Z450 D = Drive Pile (C130x180x40x4, S355 J2 + HDG)
= L9000 □120x2.60 S420GD J2 + Z450 P = Perimeter Pile (C80x180x30x4, S420 J2 + HDG)
= L7700 □120x2.60 S420GD J2 + Z450 identified by n.1 central hole as per detail)
= L6560 □120x2.60 S420GD J2 + Z450 Rails
= L10151 □120x2.20 S420GD J2 + Z450 Short rails: OMG60x32x20.5x2.0mm L430mm S350 REF. DRAW. CODE: REV. DESCRIPTION CREATED APPROVED DATE

= L8673 □120x2.20 S420GD J2 + Z450 Long rails: OMG60x32x20.5x2.0mm L1020mm S350 - 











= L8435 □120x2.20 S420GD J2 + Z450
INT. DRAW. CODE:
= L7291 □120x2.20 S420GD J2 + Z450
= L7718 □120x2.20 S420GD J2 + Z450 -
= L6574 □120x2.20 S420GD J2 + Z450
sol gua TM

SHEET: SCALE:

Out of scale
DRAWING CODE:

Via Roma 54
8/8 (PAPER SIZE: A3)
T22021-0020-EN
47035 GAMBETTOLA (FC) - ITALY DATE: DRAWING TITLE:
Piles identified by shape and central hole. Tel. +39 0547 52600

Quotes in mm
Fax +39 0547 52756
email: info@soltigua.com
12/09/22 iTracker family drawings- Poggio Renatico

You might also like