Download as pdf
Download as pdf
You are on page 1of 2
Elcome Integrated Systems Pvt.Ltd. ELCOME Corporate HO: Great Easter Summit A, 11 Floor, Plot No. 56, sector 15, CBO Belapur, Navi Mumba-400614 Tel. +91-22-6761800 fax: +91-22-67124694, e-mall: service@elcome.InWebsite: elcome. in QA 030. Issue 4 Revision No, 0 Revision Date: 1/5/2018 Service Report No.:49806 Branch Name: Mumbai Date: 27"Feb 2020 Customer/Vessel Name: M/T DIAMOND EXPRESS Agent/Owner: RADIO HOLLAND Equipment; TOKYO KEIKI GYRO COMPASS TG-8000 Sr.No.: 84302 Location: JD-2, MbPT (INDIA) ORN No. Flag: HONGKONG Customer Request: Annual servicing of Gyro compass Action Taken: - “| attended on board as below, ‘Checked & found Gyro compass was operational without any alarm. Before starts for annul servicing checked all the gyro parameters, Found within the limits. Now powered it OFF, waited for Sensitive Element to stop spinning. After that carried out annual gyro servicing as per standard OEM procedure. During servicing opened cover of master gyro compass, Checked Gyro Sensitive Element level, found ok. Checked internal wiring connections for any loose contact/damage, found all intact. Carried out STEP motor assembly checks, found motor axis rotation is smooth. Checked and cleaned Slip-ting & Brush assembly properly. After servicing covered up the gyro compass & switched it ON. Gyro compass powered up normally & started to follow up sequence properly. After 04 hours gyro is settled to its meridian. Checked gyro heading in all the Interconnected navigational equipments, found following as per master gyro compass. Annual servicing is carried out successfully and gyro compass is working satisfactorily without any alarm. This is same shown to the ships staff. | Sensitive Element Sr. No. EZ133N6SF, Installation date: Dec 2016 | Next annual service due on Feb 2021 Material Used: Sr.No. Description Item Code No. ay. Date Name Local Outstation Waiting | Travel NT or NO HD 27/02/2020 | Suresh S Pawar Oi day Feedback Excellent VeryGood — Good Satisfactory Poor 5 4 3 2 1 es Subject ] owners oN Qbbrovat: VjL vnacoase ae o ( ara) Of contrac cLauses brs Yd oe aT shee : engineer's Signature Stamp bteween oumner & Subtonb rater Elcome Integrated Systems Pvt.Ltd. = (Formerly Elcome Marine Services Pvt. Ld.) Ez Regd. Office: G-3, Arihane Building, Ahmedabad Street, ‘CIN Us3040%H1978°T.C020572 ‘Carnac Bunder, Mumbai - 400009, INDIA 491 22 23483514 / 2523 / 4518 F +91 22 23498142, E serviee@eleome.in | W:eleome.in Gyro Compass Annual Checklist VesselName = M/T DIAMOND EXPRESS Port : JD-2, MBPT (INDIA) Gyro Compass: TOKYO KEIKI Model No. T-8000 ‘Sensitive Element Sr.No. EZ133N6SF, Installation date: Dec 2016 Section Procedure ‘Status qi Check Phase Voltage OK 12 Check Phase Current ‘OK 13 ‘Check gain Voltage OK 14 ‘Check Balancing Of Sensitive Element/ Gyro Sphere ‘OK 15 ‘Check Hight Of Sensitive Element/ Gyro Sphere ‘OK 16 Check Sip Rings OK 7 ‘Check Hight & Current OF Pump Unit 5 18 ‘Check Output Voltage From Master Compass OK 19 Check Synchronization With Repeaters & Autopilot OK 2a ‘Check Synchronization With Radars, ECDIS AIS & VDR OK 22 Check Balancing Level / Liquid Level OK 23 ‘Check Overall Performance of Master Compass Functioning properly ‘The Gyro Compass having above particulars has been tested as per standard procedure by the manufacturer. Gyro compass is working satisfactorily. Date of Servicing: 27" Feb 2020 ‘Next Servicing Due: 26" Feb 2021 Serviced By: Suresh Pawar Plot No. EL-205, MIDC Mahape,TTC industrial Area, Navi Mumbai, Maharashtra - 400710, INDIA #91 22 67618000 | F +91 22 6712 4694 E sales@eleome.in

You might also like