Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

Oyu Tolgoi LLC

OT Underground Project – HNL1

EQUIPMENT NUMBERING PROCEDURE

0000-00-PRC-0055
Document Information
Details
Document Number 0000-00-PRC-0055

Description The procedure for assigning tag numbers to asset equipment at OT


Mine Site
Original Author(s) Darren Brady/Peter Howes

Creation Date December 14, 2016

Revision History
Rev Date Author(s) Approved Revision Notes
0 20/12/16 Darren Brady/Peter Symon Brushe for Issued for Use
Howes Matt Betts (21/12/16)

1 27/03/17 Darren Brady Brushe, Digitally signed by Brushe, Symon


(G&I) Updated Mechanical,
Symon
DN: dc=org, dc=riotinto, dc=corp,
ou=PROD, ou=APAC, ou=AU-Brisbane,
ou=People, cn=Brushe, Symon (G&I),
email=Symon.Brushe@riotinto.com
Electrical and Telecomms
(G&I) Date: 2017.03.27 13:19:17 +10'00'
Equipment Code Lists

Document Approval

Date Approver Name Approver Signature Company Seal Stamp

OTUP Project Owner:


Darren Brady

Ops Readiness
Andrew Pattison

Procedure Approver:
Matt Betts
Symon Brushe for Matt Betts

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 2 of 29 0000-00-PRC-0055 Rev.1


Table of Contents
OT Underground Project – HNL1 1

1. PURPOSE 5

2. SCOPE 5

3. REFERENCES 5

4. RESPONSIBILITES 5
4.1. Operational Readiness 5

5. EQUIPMENT NUMBERING 5
5.1. Functional Parent-Child Relationships 5
Table 5.2.1: Conveyor Functional Relationships 6
5.2. Main Mechanical Electrical & Telecommunication Equipment Numbering
6
Table 5.2 Main equipment numbering 6
5.2.1. Associated Equipment 7
Table 5.2.1: Associated Equipment 7
5.2.2. Equipment Assemblies 8
Table 5.2.2: Equipment Assemblies 8
5.2.3. Equipment Naming Descriptions 8
Table 5.2.3: Equipment Naming Descriptions 8
5.3. Piping Numbering 9
5.3.1. Pipe Run Numbering 9
5.3.2. Pipe Line Numbering 9
Table 5.3.2 Line Numbering Code 9
5.4. Valve Numbering 10
Table 5.4: Valve Numbering 10
5.4.1. Valve Designation Numbering 10
Table 5.4.1.1: Valve Numbering Codes 10
Table 5.4.1.2: Valve Type Codes 11
5.4.2. Manually Actuated Valves 11
Table 5.4.2: Manual Valve Numbering Codes 11
5.4.3. Control System Actuated Valve Tag Numbering 12
Table 5.4.3: Control System Valve Numbering Codes 12

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 3 of 29 0000-00-PRC-0055 Rev.1


5.5. Instrumentation 12
5.5.1. Instrument Loop 12
5.5.2. Instrument Numbering 12
Table 5.5.2: Instrumentation Numbering Codes. 13
5.6. Cable Numbering 13
5.6.1. Category 1 Cable Numbering 13
Table 5.6.1.1 Category 1 Cable Numbering Codes 13
Table 5.6.1.2 Cable Codes 14
5.6.2. Cat 1 Power Cable Numbering 14
Table 5.6.2: Power Cable numbering codes 14
5.6.3. Cat 1 Light and Power Socket Cable Numbering 15
Table 5.6.3: Cable numbering codes 15
5.6.4. Category 2 Cable Numbering 16
Table 5.6.4.1 Category 2 Cable Numbering Codes 16
Table 5.6.4.2 Category 2 Cable Type Codes 17
APPENDIX A: OT MECHANICAL EQUIPMENT CODE LIST 18
APPENDIX B: OT ELECTRICAL EQUIPMENT CODE LIST 24
APPENDIX C: TELECOMMUNICATION CODE LIST 26
Table 1 - ANSI/ISA-5.1 Typical Letter Combinations 27
APPENDIX E: CONTROL SYSTEM ACTUATED VALVE TYPE CODE 28
Table 2 - ANSI/ISA-5.1 Typical Letter Combinations 28

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 4 of 29 0000-00-PRC-0055 Rev.1


1. PURPOSE

This document describes the procedure used by OT AIMT to assign tag numbers to OT
Operations equipment.

2. SCOPE

This numbering procedure is to be used for issuing tag numbers for new equipment in both
green and brownfield areas.

3. REFERENCES

This document makes reference to the following additional documents:


• OTUP Document Control Standard 0000-00-STD-0007
• OTLLC PBS Codes 0000-00-STD-1024
• OTUP WBS Codes 0000-30-STD-9000
• Piping Design Criteria 0000-50-DCR-0001
• Piping Line Class 0000-50-SPE-0001
• Pipe Fabrication, Installation and Commissioning Specification 0000-50-SPE-0003
• Valve Specification 0000-50-SPE-0004
• Pipe Fabrication and Installation of HDPE Piping Specification 0000-50-SPE-0005

4. RESPONSIBILITES

4.1. Operational Readiness


The asset equipment tag number shall be a unique identifier in the OT Engineering Data
Management System and determined by the rules of this standard and based on metadata
input from the Equipment Owner.

5. EQUIPMENT NUMBERING

New equipment installed for the OT Underground Project – HNL1 at the Oyu Tolgoi mine
facility shall follow this numbering procedure.

5.1. Functional Parent-Child Relationships


To limit the length of the equipment tag numbers, the relationship between pieces of
equipment, where they are part of a sub-assembly, shall be shown on a functional basis, rather
than on a physical basis.
Figure 5.2.1 and Table 5.2.1 demonstrate the functional relationships between multiple pieces
of equipment on a conveyor. In this instance, all components within a drive module (sub-
assembly) are linked to the drive as a parent, rather than to their physical connection, i.e. the
motor (MTR) is connected functionally to the drive, not physically to the gearbox (GEA).

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 5 of 29 0000-00-PRC-0055 Rev.1


Figure 5.2.1: Conveyor Functional Relationships

Table 5.2.1: Conveyor Functional Relationships


Grandparent Parent Child
Conveyor (CVB) Variable Frequency Drive (VFD)
Conveyor (CVB) Pulley (PUL)
Conveyor (CVB) Pulley (PUL)
Conveyor (CVB) Drive (DRV)
Conveyor (CVB) Drive (DRV) Gearbox (GEA)
Conveyor (CVB) Drive (DRV) Backstop (BST)
Conveyor (CVB) Drive (DRV) Motor (MTR)
Conveyor (CVB) Drive (DRV) Fan #A (FAN)
Conveyor (CVB) Drive (DRV) Variable Frequency Drive #A
Conveyor (CVB) Drive (DRV) Fan #B (FAN)
Conveyor (CVB) Drive (DRV) Variable Frequency Drive #B

5.2. Main Mechanical Electrical & Telecommunication Equipment Numbering


The format for Main Equipment tag numbers is VVVV-EEE-(N)NNN where the codes used are
defined in Table 5.2.
Table 5.2 Main equipment numbering
Code Description

VVVV Plant Breakdown Structure (PBS) code


Refer to document 0000-00-STD-1024 for complete listing of PBS
codes. NOTE: Where existing equipment has a process related function
to the new equipment and has been allocated a WBS code as its prefix,
then in this case the WBS code will be used as the assigned PBS.
Refer to document 0000-30-STD-9000

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 6 of 29 0000-00-PRC-0055 Rev.1


EEE Equipment Code
The specific three character alpha codes. Refer to Appendix A
(Mechanical), Appendix B (Electrical) and Appendix C
(Telecommunication)
NNN Sequence Number
This is a three digit sequential number and is unique identifier for similar
types of equipment per PBS area.
(N)NNN Sequential Number
For underground project HNL1, the asset numbers will start from 2000
(For underground
project HNL1 – the
to distinguish it from the three digit sequence created for existing
sequential number assets. This is a four digit sequential number and is unique identifier for
will start from 2000) similar types of equipment per WBS area. Sequence identifiers for each
equipment code will be sequential and when the WBS code changes
the sequence identifier can be reset.

Example 5.2: Main Equipment


3120-CVB-011 Primary Crusher Discharge Conveyor
1860-CVB-2001 Underground Coarse Ore Overland Conveyor (HNL1 project)
1118-SWP-2001 35kV Switchboard (HNL1 project)

5.2.1. Associated Equipment


Where there is equipment associated with the main piece of equipment, an equipment number
extension shall be used. In this relationship the main piece of equipment is considered the
“parent” and the associated equipment is called the “child”, as its existence is dependent on
the main equipment.
The format for Associated Equipment tag numbers is VVVV-EEE-(N)NNN-EEES where the
codes used are defined in Table 5.3.1.
Table 5.2.1: Associated Equipment
Code Description

VVVV-EEE-(N)NNN Primary (Parent) Equipment code


Refer to clause 5.3. Main Mechanical & Electrical Equipment
Numbering
EEE Equipment Code
The specific three character alpha codes. Refer to Appendix A
(Mechanical) and Appendix B (Electrical) and Appendix C
(Telecommunication)
A Suffix (if required)
An alpha code that uniquely identifies same type of equipment in the
circuit (Note: Suffix does not apply to parent equipment)

Example 5.2.1: Associated Equipment


1867-PUM-2006 Surface Fuel Transfer Pump No. 2 (parent equipment)
1867-PUM-2006-MTR Surface Fuel Transfer Pump No. 2 Motor (child equipment)
3550-PUM-2001-VFD Pump (3550-PUM-2001) Variable Frequency Drive (child
equipment)
The above example illustrates the use of parent to child equipment number, or equipment
number extension, to identify a motor (MTR) associated with the main mechanical equipment.
In the case of multiple motors, the motors are uniquely identified with ‘A’, ‘B’, ‘C’ etc.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 7 of 29 0000-00-PRC-0055 Rev.1


5.2.2. Equipment Assemblies
Where equipment is part of an assembly, for example a conveyor drive consisting of a
gearbox, motor and oil cooler, the format will be VVVV-EEE-2NNN-EEES-EEES where the
codes used are defined in Table 5.3.2

Table 5.2.2: Equipment Assemblies


Code Description
VVVV-EEE-(N)NNN- Parent Equipment Number
EEES

EEE Equipment Code


This is a three character alpha code identifying the equipment
type as defined in Appendix A of this procedure.
S Suffix (if required)
This is a single alpha code, starting with ‘A’, and is a unique
identifier for the same type of equipment sharing a common
load/duty.

Example 5.2.2: Equipment Subassemblies


1833-CVB-2001-DRVA Conveyor 2001 drive assembly A (parent equipment)
833-CVB-2001-DRVA-MTR Conveyor 2001 drive assembly A Motor (child equipment)
1833-CVB-2001-DRVA-FAN Conveyor 2001 drive assembly A Motor Fan (child equipment)
3500-GHE-021 Glycol Unit Heater (Grand-parent)
3500-GHE-021-MTR Glycol Unit Heater – Motor (Parent)
3500-GHE-021-MTR-PBS Glycol Unit Heater Motor - Push Button Station (Child)
1821-CVB-2005-VFDA Conveyor Belt (1821-CVB-2005) VFD A
1821-CVB-2005-VFDB Conveyor Belt (1821-CVB-2005) VFD B
1821-CVB-2005-VFDC Conveyor Belt (1821-CVB-2005) VFD C
1118-SWG-2001-BUSA Switchboard (1118-SWG-2001) Bus A
1118-SWG-2001-BUSB Switchboard (1118-SWG-2001) Bus B
1118-SWG-2001-BUSB Switchboard (1118-SWG-2001) Bus C

5.2.3. Equipment Naming Descriptions


The naming descriptions given to equipment shall follow the same system to that used for the
numbering system. Table 5.3.2 demonstrates the naming of parent and child equipment.
Table 5.2.3: Equipment Naming Descriptions
Grand - Parent Child Equipment Tag Equipment Name
parent Number
Conveyor (CVB) 1524-CVB-2035 Conveyor
Var.Freq.Drive
Conveyor (CVB) 1524-CVB-2035-VFD Variable Frequency Drive
(VFD)
Conveyor (CVB) Pulley (PUL) 1524-CVB-2035-PULA Conveyor, Tail Pulley
Conveyor (CVB) Pulley (PUL) 1524-CVB-2035-PULB Conveyor, Head Pulley

Conveyor (CVB) Drive (DRV) 1524-CVB-2035-DRV Conveyor, Drive

Gearbox
Conveyor (CVB) Drive (DRV) 1524-CVB-2035-DRV-GEA Conveyor, Drive Gearbox
(GEA)
Backstop
Conveyor (CVB) Drive (DRV) 1524-CVB-2035-DRV-BST Conveyor, Drive Backstop
(BST)

Conveyor (CVB) Drive (DRV) Motor (MTR) 1524-CVB-2035-DRV-MTR Conveyor, Drive Motor

1524-CVB-2035-DRV-
Conveyor (CVB) Drive (DRV) Fan #A (FAN) Conveyor, Drive Motor, Fan A
FANA

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 8 of 29 0000-00-PRC-0055 Rev.1


Var.Freq.Drive 1524-CVB-2035-DRV- Conveyor, Drive Motor Fan,
Conveyor (CVB) Drive (DRV)
#A VFDA Variable Frequency Drive A

1524-CVB-2035-DRV-
Conveyor (CVB) Drive (DRV) Fan #B (FAN) Conveyor, Drive Motor, Fan B
FANB

Var.Freq.Drive 1524-CVB-2035-DRV- Conveyor, Drive Motor Fan,


Conveyor (CVB) Drive (DRV)
#B VFDB Variable Frequency Drive B

5.3. Piping Numbering

5.3.1. Pipe Run Numbering


The format of the pipe run number is VVVV-FFFF-NNNN where the codes used are defined in
Table 5.3.2
The pipe run is the tag that is assigned to the same pipe that can vary in diameter and
insulation along its length. A pipe run stays the same piping class for the full length of the pipe.
The pipe run is composed of one or more pipe lines as defined in clause 5.3.2.

5.3.2. Pipe Line Numbering


The format of pipe line numbers is VVVV-FFFF-NNNN-MMM-SSS-II where the codes used are
defined in Table 5.3.2
Table 5.3.2 Line Numbering Code
Code Description
VVVV Plant Breakdown Structure (PBS) code
Refer to document 0000-00-STD-1024 for complete listing of PBS codes
NOTE: Where existing equipment has a process related function to the
new equipment and has been allocated a WBS code as its prefix, then in
this case the WBS code will be used as the assigned PBS. Refer to
document 0000-30-STD-9000
FFFF Fluid Code.
This is a three or four digit code that denotes the types of fluid contained
in the pipeline. Refer to Pipe Specification 0000-50-SPE-0001 for a full
listing of Fluid Codes.
(N)NNN Pipe sequence number
For underground project HNL1, the asset numbers will start from 2000 to
(For Underground distinguish it from the three digit sequence created for existing assets.
Project HNL1 – This is a four digit sequential number and is unique identifier for same
the sequential types of fluid code per PBS area. Sequence identifiers for each pipe line
number will start will be sequential and when the PBS code changes the sequence
from 2000) identifier can be reset.
MMM Pipe Material Class
This is a three character alpha code identifying the pipe material class.
Refer to:
Piping Class Standard 0000-50-SPE-0001
Piping Line Class Supplement (0000-50-SPE-0001 Addendum) SP-50-
206
Piping Line Class Supplement (Piping Class No.H0CA) SP-50-208
SSSS Pipe Size
(Metric) This is a 3 or 4 digit number which identifies the diameter of the pipe in
millimeters.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 9 of 29 0000-00-PRC-0055 Rev.1


SSSS Pipe Size
(Imperial) This is a four character number, which comprises of three digits which
identifies the pipe size in inches, followed by a double inverter comma (”)
to identify the pipe as imperial.
For non-preferred pipe sizes, one of the digits will be replaced by a full
stop (.) to allow for half inches.
For small bore pipes, one of the digits will be replaced by a forward slash
(/) to allow for fractions of inches.
II Insulation Code
This is a two character alpha code identifying the pipe insulation code
Refer to:
Thermal Insulation SP-50-022
Example 5.3.1 Pipe Line Numbering
1519-DF-003-C1L-008”-IH Surface Fuel Line #3 – 8 inches, Insulated for heat conservation
1519-DF-2005-C1L-012”-IH Surface Fuel Line #2005 – 12 inches, Insulated for heat conservation

1519-DF-2030-C1L-2.5”-AF Surface Fuel Line #30 – 21/2 inch pipe


5741-FW-099-C1F-0100-AF CHP Firewater Line #99 – 100mm pipe

5.4. Valve Numbering


Valves shall be allocated two numbers to provide adequate identification and information on
drawings and in the field. The requirements for valve numbering are detailed in Table 5.4.2.
Table 5.4: Valve Numbering
Valve Number Type Shown on Drawing Shown on Field Tag
Valve Designation YES NO
Valve Tag YES YES

5.4.1. Valve Designation Numbering


The format for Valve numbers on drawings is SSSS-EE-NNNNNNN where the codes used are
defined in Table 5.4.1.1
Table 5.4.1.1: Valve Numbering Codes
Code Description
SSSS Valve Size
(Metric) This is a four digit number which identifies the nominal diameter (DN) of the
valve in millimeters.
SSSS Valve Size
(Imperial) This is a four character number, which comprises of three digits which
identifies the nominal pipe size (NPS) of valve in inches, followed by a double
inverter comma (”) to identify the pipe as imperial.
For non-preferred pipe sizes, one of the digits will be replaced by a full stop (.)
to allow for half inches.
For small bore pipes, one of the digits will be replaced by a forward slash (/) to
allow for fractions of inches.
EE Valve Type Code
This is a two digit code to show the valve type description. Refer to table
5.4.2.1.2
NNNNNNN Valve Item Code
This is a four to seven character code, used in conjunction with the Valve Type
code to determine the specification of the valve. Refer to Pipe Specification
SP-50-0001 for a full listing of Valve Item codes.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 10 of 29 0000-00-PRC-0055 Rev.1


Table 5.4.1.2: Valve Type Codes
Code Valve Description
BA Ball
BU Butterfly
CH Check
GA Gate
GL Globe
KG Knife gate
NE Needle
PL Plug
PN Pinch
AV Air or Vacuum release

Example 5.4.1 Valve Designation Numbering


0100-BU-1010G DN100 150PSI Butterfly Valve
¼”-BA-1001 ¼ inch 400PSI Ball Valve

5.4.2. Manually Actuated Valves


The format for manually actuated valve numbers is VV(VV)-HV-(N)NNN-S where the codes
used are defined in Table 5.4.2.2
Table 5.4.2: Manual Valve Numbering Codes
Code Description
VV(VV) First two characters of Plant Breakdown Structure (PBS) code for
Concentrator only which denote Area and Sub Area. All other
areas use the four character PBS Code
Refer to document 0000-00-STD-1024 for complete listing of PBS
codes. NOTE: Where existing equipment has a process related
function to the new equipment and has been allocated a WBS code as
its prefix, then in this case the first 2 characters of the WBS code will
be used as the assigned PBS. Refer to document 0000-30-STD-9000
HV Valve Type
This is a two character alpha code identifying the valve type. For all
hand valves which are manually operated (non-actuated) this code
shall be HV only.
NNNN Piping sequential number
This is a three or four digit sequential number and is unique identifier
for similar types of equipment per PBS area.
(N)NNN Sequential Number
For underground project HNL1, the asset numbers will start from 2000
(For Underground
to distinguish it from the three digit sequence created for existing
Project HNL1 – the
assets. This is a four digit sequential number and is unique identifier
sequential number will for similar types of equipment per WBS area. Sequence identifiers for
start from 2000) each equipment code will be sequential and when the WBS code
changes the sequence identifier can be reset.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 11 of 29 0000-00-PRC-0055 Rev.1


S Suffix (if required)
This is a single alpha character, starting with ‘A’, and is required if two
of the same instrument are in the same loop.
Example 5.4.2: Manually Actuated Valve Tag Numbering
34-HV-4761-A SAG Mill Main Bearing Lubrication System Filters.

5.4.3. Control System Actuated Valve Tag Numbering


The format for control system actuated valve tag numbers is VV(VV)-TTTTT-YYNNS where the
codes used are defined in Table 5.4.2.3.
Table 5.4.3: Control System Valve Numbering Codes
Code Description
VV ) First two characters of Plant Breakdown Structure (PBS) code for
Concentrator only which denote Area and Sub Area. All other areas
use the four character PBS Code
Refer to document 0000-00-STD-1024 for complete listing of PBS codes.
TTTTT Valve Type
This is a two to five character alpha code identifying the valve type. For a
complete listing of valve code combinations. Refer to Appendix E of this
Procedure.
YY Piping and Instrument Diagram Number
This is the last two digits of the sequential number in the P&ID drawing
number.
NN Valve Sequence Number
If the instrument is not associated with a loop, then use a two digit
sequential number.
C Suffix (if required)
This is a single alpha character, starting with ‘A’, and is required if two of the
same instrument are in the same loop.
Example 5.4.3: Control System Actuated Valve Tag Numbering
34-FCV-0403A A flow control valve installed on Grinding circuit SAG Mill
P&ID 3400-25J-104

5.5. Instrumentation

5.5.1. Instrument Loop


The format of the instrument loop number is VV(VV)-T(T)-XXYY where the codes used are
defined in Table 5.5.2
The instrument loop diagram is a composite representation of instrument loop information. It
contains all associated electrical and piping connections and should contain all of the
information needed to accommodate the intended uses.
The instrument loop is the tag that is assigned to the collection of instruments that measure
and control the process flow. The instrument loop is composed of one or more instruments as
defined in clause 5.5.2.

5.5.2. Instrument Numbering


The instrumentation equipment tag number consists of four main fields to create a unique
identification for each piece of equipment.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 12 of 29 0000-00-PRC-0055 Rev.1


The format for instrumentation tag numbers will be VV(VV)-TTTTT-XXYYS where the codes
used are defined in Table 5.5:
Table 5.5.2: Instrumentation Numbering Codes.
Code Description
First two characters of Plant Breakdown Structure (PBS) code for
Concentrator only which denote Area and Sub Area. All other areas
VV(VV) use the four character PBS Code
Refer to document 0000-00-STD-1024 for complete listing of PBS codes.

Instrument Type
TTTTT This is a two to five character alpha code identifying the instrumentation
type as defined in Appendix D (Instrumentation) of this document.

Piping and Instrument Diagram Number


XX This is the last two digits of the sequential number in the P&ID drawing
number.
Loop Sequence Number
YY
If the instrument is not associated with a loop, then use 00
Suffix (if required)
S This is a single alpha character, starting with ‘A’, and is required if two of
the same instrument are in the same loop.

Example 5.5.2: 32-HS-0282A


Where 3200 – PBS; HS – Hand actuated switch; P&ID drawing number: 3200-25J-102

5.6. Cable Numbering


Cable numbering is defined in the following two categories. The first category is for numbers
associated with discrete equipment or instruments. The second category is used for cables
that connect to items that do not necessarily have equipment or instrument numbers. An
example of this would be the cabling required for the grounding of structural steelwork.
5.6.1. Category 1 Cable Numbering
This category of cable numbering is associated with equipment that has a defined equipment
or instrument number.
The format for Category 1 Cable Numbering is VVVVEEE(N)NNN-YCC for equipment cables
and VVVVTTTTTXXYYS-YCC for instrumentation cables, where the codes used are defined in
Table 5.6.1.1
Table 5.6.1.1 Category 1 Cable Numbering Codes
Code Description
VVVVEEE(N)NNN Equipment Number
This is the associated Equipment tag with the hyphens removed.
VV(VV)TTTTTXXYYS Instrument Number
This is the associated Instrument tag with the hyphens removed
Y Cable Code
This is a single alpha character that identifies the type of cable as
summarised in the Table 5.6.1.2.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 13 of 29 0000-00-PRC-0055 Rev.1


CC Sequential Number
This is a double digit sequential number and is unique identifier
for multiple cables of the same type running to a particular
instrument or equipment

Table 5.6.1.2 Cable Codes


Code Category Code Category
C Control Cables M Miscellaneous Cables

D Distributed Control System Cables N Neutral Cables

E Earth Cables P Power Cables HV and LV

J Instrument Cables T Thermistor Cables

F Fibre Optic Cables

Example 5.6.1: Cable Numbering


1860PUM101-P01 10.5kV cable from HV circuit breaker to 1860-PUM-101
1860PUM2101-C01 10 core +e control cable to 1860-PUM-2101 VFD drive
1860VCP1181-M01 Fiber optic cable to instrument control panel 1864-CP-1181
5.6.2. Cat 1 Power Cable Numbering
The numbering of power cables is dependent upon the core type. The format for power cable
numbering is VVVVEEE(N)NNN-YCPN for single core (phase) and VVVVEEE(N)NNN-YCS for
3 core (phase) power cables. The codes used are defined in Table 5.6.1.1
Table 5.6.2: Power Cable numbering codes
Code Description
VVVVEEE(N)NNN Equipment Number
This is the associated Equipment tag with the hyphens removed.
Y Cable Code
This is a single alpha character that identifies the type of cable. For
power cables the code is P only.
C Sequential Number
This is a single digit sequential number and is unique identifier for
multiple cables of the same type running to a particular instrument or
equipment.
P Phase
This is a single alpha character that identifies the phase. Acceptable
characters are U, V, W and N, in accordance with IEC 60445.
N Sequential Number (of phase) This is a single digit sequential number
and is a unique identifier for multiple phases running to a particular
instrument or equipment.
S Phase Suffix
This is a single alpha sequential character and is a unique identifier for
multiple multicore cables run to a particular piece of equipment.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 14 of 29 0000-00-PRC-0055 Rev.1


Example 5.6.2: 2 off 400V power supply required for 1864-PUM-2001-P1; single core cables
1864-PUM-2001-P1U1 --------------------------->
1864-PUM-2001-P1V1 --------------------------->
1864-PUM-2001-P1W1 -------------------------->
1864-PUM-2001-P1N1 ---------------------------> 1864-PUM-2001
1864-PUM-2001-P1U2 ---------------------------> Motor
1864-PUM-2001-P1V2 --------------------------->
1864-PUM-2001-P1W2 -------------------------->
1864-PUM-2001-P1N2 --------------------------->
Example 5.6.2.2: 2 off 400V power supply required for 1864-PUM-2001-P1; 3 core cables
1864-PUM-2001-P1A ------------------------------>
1864-PUM-2001
1864-PUM-2001-P1B ------------------------------> Motor

5.6.3. Cat 1 Light and Power Socket Cable Numbering


All power cable numbers to lighting and power socket outlets shall indicate the supply point
distribution board (or control panel) hyphenated with the circuit breaker number.
The format of the cable numbering is VVVVEEE(N)NNNS-CBNN where the codes used are
defined in Table 5.6.3
Table 5.6.3: Cable numbering codes
Code Description
VVVVEEE(N)NNNS Electrical Equipment Number
This is the associated Equipment tag with the hyphens removed.
CBNN Circuit Breaker
This is a two alpha character that identifies the circuit breaker (CB)
number NN at supply point
Example 5.6.3: Lighting and power socket numbering.
1585-PDP-2401 400/230V Power Distribution Panel
1585PDP2401-CB01 PDP (1585-PDP-2401) Circuit Breaker 01 power cable(s) to lights
1585PDP2401-CB02 PDP (1585-PDP-2401) Circuit Breaker 02 power cable(s) to socket
outlets

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 15 of 29 0000-00-PRC-0055 Rev.1


Sketch:

Note that junction boxes are not numbered.

5.6.4. Category 2 Cable Numbering


This category of numbers is used for cabling to equipment that does not necessarily have an
equipment or instrument number. They are predominantly used for data and earth cabling and
in the format VVVV- YYYYY-BNNN where the codes used are defined in Table 5.6.4.
Table 5.6.4.1 Category 2 Cable Numbering Codes
Code Description
VVVV Plant Breakdown Structure (PBS) code
Refer to document 0000-00-STD-1024 for complete listing of PBS
codes. NOTE: Where existing equipment has a process related function
to the new equipment and has been allocated a WBS code as its prefix,
then in this case the WBS code will be used as the assigned PBS.
Refer to document 0000-30-STD-9000
YYYYY Cable Code
This is a two to five alpha character that identifies the type of cable as
summarized in the Table 5.5.2
BNNN Block and Sequential Number
This is a three digit sequential number and is unique identifier for each
type of cable. For example, a new telephone cable would use the next
sequential number from the ‘TEL’ cable prefix series.

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 16 of 29 0000-00-PRC-0055 Rev.1


Table 5.6.4.2 Category 2 Cable Type Codes
Code Category Code Category

COMM Communication Cables EP Earth Cables – Power Circuits


TELEM Telemetry Cables EJ Earth Cables – Instrument Circuits
SECT Security Cables FIBRE Fibre Cables
TEL Telephone Cables FIRE Fire Cables

Example 5.6.4 Category 2 Cable Numbering


3400-TEL-031 Concentrator Grinding Telephone Line #31

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 17 of 29 0000-00-PRC-0055 Rev.1


APPENDIX A: OT MECHANICAL EQUIPMENT CODE LIST
MANDATORY CODES
FOR
CODE EQUIPMENT DESCRIPTION PARENT CLASSIFICATION
UNDERGROUND
PROJECT HNL1
ACO Air Compressor Parent
ACP Access Control Panel X
ACT Actuator X
ACU Air Conditioning Unit Parent if stand alone X
ACV Activator X
AFA Auxiliary Cooling Fan Parent if stand alone
AGG Agglomeration Drums Parent X
AGI Agitator Parent X
AHE Auxiliary Heater Parent if stand alone
AHS Air Hose Station Parent X
AHU Air Handler Unit Parent if stand alone X
AIC Air Conditioner (Local) Parent if stand alone
AIL Air Lock Parent X
AMX Auxiliary Mixer Parent if stand alone
ANA Analyser Parent X
ANO Anode Parent X
APU Auxiliary Pump Parent if stand alone
AXL Axle X
BAC Backhoe Parent X
BAG Baghouse Parent
BAI Bailer Parent X
BAR Barrel Pump
BCL Belt Cleaner
BIN Bin Parent if stand alone X
BLA Blanks X
BLD Building Parent X
BLO Blower Parent if stand alone X
BLW Bellow X
BOA Barge Parent X
BOI Boiler Parent X
BOL Bottling Line Parent X
BOX Blasting System Parent X
BRG Bearing X
BRK Brake X
BST Backstop X
BUC Bucket X
BXP Pump Box
CAG Cage Parent X
CAR Car X
CAT Cathode X
CCU Central Control Unit X
CDG Chlorine Dioxide Generator Parent X
OT LLC EQUIPMENT NUMBERING PROCEDURE Page 18 of 29 0000-00-PRC-0055 Rev.1
CEL Cell X
CEN Centrifuge Parent X
CHA Chamber Parent X
CHI Chiller Parent X
CHL Chlorinator Parent X
CHM Chimney Parent if stand alone X
CHN Chain X
CHU Chute X
CLD Clamping Lifting Device X
CLE Cleaner X
CLJ Clare Jester X
CLR Clarifier Parent X
CLS Classifier Parent X
CMP Compressor Parent X
CNC Concentrator Parent X
CND Condenser Parent if stand alone X
CNV Converter X
COL Collector Parent if
feeding/collecting for
multiple equipment X
CON Conveyor Parent X
COO Cooler Parent if stand alone
COW Cowl X
CPA Compactor Parent X
CPS Coupling Shaft X
CRA Crane Parent X
CRB Crusher Boom Crane Parent
CRH Crosshead X
CRJ Crusher – Jaw Parent
CRM Crane – Maintenance Parent
CRU Crusher Parent X
CSM Cathode Stripping Machine Parent X
CTG Catch Gear X
CTS Carts X
CUT Cutter X
CVB Conveyor Belt Parent X
CYC Cyclone Parent X
CYL Cylinder
DAM Damper Parent if stand alone X
DCD Dust Suppression System Parent X
DCM Down Comer X
DEA De-aerator Parent X
DEP Department Parent X
DIP Dipper X
DMP Dump Pocket Parent
DOC Dock Parent X
DOO Door Parent X

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 19 of 29 0000-00-PRC-0055 Rev.1


DOS Chemical Dosing Unit Parent X
DOZ Dozer Parent X
DRA Dragline Parent X
DRI Drill Parent X
DRU Drum X
DRV Drive X
DRY Dryer Parent X
DUC Duct X
EBH Electric Convector X
ECO Economizer Parent if stand alone X
ELE Elevator Parent X
ENG Engine Parent if stand alone X
EQP Equipment Parent X
EWC EW Cells Parent X
EXA Excavator Parent X
EXJ Expansion Joint X
EXP Expander X
FAN Fan Parent if stand alone X
FDA Feeder – Apron Parent X
FDR Feeder – Belt Parent X
FDS Feeder - Screw Parent X
FDV Feeder - Vibrating Parent X
FHS Fire Hose Station Parent X
FIL Filter Parent X
FLO Flotation Parent X
FLT Filter - Water
FLW Flywheel X
FMW Formwork X
FOR Forklift Parent X
FRM Cathode Harvesting Bales Parent X
FSS Fire Suppression System Parent X
Parent if it is a fuel
FUD Fuel Dispenser station X
FUR Furnace Parent X
GEA Gearbox X
GFE Extinguisher Parent X
GHE Glycol Heater Parent if stand alone
GRA Grader Parent X
GRI Grizzly Parent X
HAN Handler Parent X
HEA Heater Parent if stand alone
HED Steam Header X
HEX Heat Exchanger Parent if stand alone X
HHS Hydrocarbon Hose Station Parent X
HOI Hoist (Shaft Hoisting Equipment Only) Parent X
HPR Hopper Parent if stand alone
HPU Hydraulic Power Unit Parent if stand alone

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 20 of 29 0000-00-PRC-0055 Rev.1


HTR Heater Unit Parent if stand alone X
HTU Take-Up Parent if stand alone X
HWB Hot Water Boiler Parent
HWT Hot Water Tank - Domestic Parent
HYU Hydraulic Unit / Power Pack X
IDL Idler X
IEX Sodium Ion Exchanger Parent X
IMP Impactor Parent X
LAB Lab Equipment X
LAD Ladle Parent X
LAU Launder Parent X
LBL Lifting Blocks X
LDA Loading Arm X
LOA Loader Parent X
LOC Locomotive Parent X
LOV Louver X
LUS Lubricating System Parent if stand alone X
MAC Machine Parent X
MAN Man Lift Parent X
MDE Metal Detector Parent if stand alone X
MGT Magnet Parent if stand alone X
MIL Mill Parent X
MIX Mixer Parent X
MOL Mold X
MRH Monorail Hoist Parent
MXS Mixer / Settler Parent
ORI O-Ring X
OZG Ozone Generator X
PAR Park
PCP Pump Control Panel X
PIN Pinion X
PLA Plant Parent
PLE Plenum Parent X
PNP Control Panel X
POL Polisher Parent X
PON Pond/Dam Parent X
POT Pot Parent X
PRE Precipitator Parent X
PRH Preheater Parent if stand alone
PRS Press Parent X
PRT Part X
PRU Pressurization Unit Parent X
PUL Pulley X
PUM Pump Parent X
PUV Pulveriser Parent X
RAC Railroad Car Parent X

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 21 of 29 0000-00-PRC-0055 Rev.1


RAD Radiator Parent if stand alone X
RAI Railroad Parent X
REC Receiver Parent if stand alone X
REO Reverse Osmosis Unit Parent X
RER Reclaimer Parent X
RKB Rock Breaker Parent X
ROA Road Parent X
ROD Rod X
ROL Roller
ROP Rope X
ROV Rotary Valve X
SAG Supply Air Grill X
SAM Sampler Parent if stand alone X
SAW Saw Parent X
SCA Scale Parent if stand alone X
SCB Scale – Belt Parent X
SCD Screen Deck Media X
SCN Screen Parent X
SCU Scrubber Parent X
SEP Separator Parent X
SEW Safety Eye Wash Parent X
SHA Shaker Parent X
SHE Shear Parent X
SHO Shovel Parent X
SHV Sheave X
SIL Silencer X
SKD Skid Parent X
SKI Skip Parent X
SLA Slaker X
SLI Slitter Parent X
SPB Spile Bars X
SPL Splitter Box Parent if
feeding/collecting for
multiple equipment X
SRG Speed Reducer
SSE Sewage System Equipment Parent X
SSW Safety Shower Parent X
STA Stacker Parent X
STB Strongback X
STG Stage Parent X
STN Station Parent X
STO Storage Racks Parent X
STP Stripper Parent X
STR Straightener X
SUM Sump Parent X
SUS Suspension X
SWE Sweeper Parent X

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 22 of 29 0000-00-PRC-0055 Rev.1


THI Thickener Parent X
TNF Tank Farm Parent
TNH Tank House Parent
TNK Tank Parent X
TRA Tractor Parent X
TRD Turbine Driver Parent X
TRE Trencher Parent X
TRL Trailer Parent X
TRM Mine Haul Truck Parent X
TRO Trolley Parent X
TRU Truck Parent X
TRX Traxcavator Parent X
TUR Turbine Parent X
UDJ Underground Drilling Jumbo / Bolter Parent X
ULD LHD Unit (Diesel) Parent X
ULE LHD Unit (Electric) Parent X
UME Underground Mobile Equipment Parent X
USV Underground Utility / Service Vehicle Parent X
UTR Underground Mine Truck Parent X
UVL UV Lamp System X
VCD Volume Control Damper Parent X
VEH Vehicle Parent X
VES Vessel Parent X
VET Ventilator Parent X
VUL Vulcanizer Parent X
WAS Washer X
WAT Water Softener X
WDR Welder Parent X
WEL Well Parent X
WEI Weigher X
WHE Wheel X
WHS Water Hose Station Parent X
WIN Winch Parent if stand alone X
WNH Winch Hoist Parent if stand alone
WSS Water Spray System X
WWT Waste Water Treatment Parent X

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 23 of 29 0000-00-PRC-0055 Rev.1


APPENDIX B: OT ELECTRICAL EQUIPMENT CODE LIST

MANDATORY CODES
CODE EQUIPMENT DESCRIPTION PARENT CLASSIFICATION FOR
UNDERGROUND
PROJECT HNL1
ALT Alternator X
BAN Battery Bank X
BCR Battery Charger X
CAP Capacitor Bank X
CBK Circuit Breaker X
CEB Clean Earthing Bars X
CNP Control Panel Parent X
CPU Computer Parent X
CTR Current Transformer X
DCL DC Link Reactor X
DCP DC Panel Parent if stand alone X
DOF Dropout Fuse X
DSW Disconnect Switch X
EAB Earthing Bars X
EEP Earthing Pit X
EHT Electrical Heat Trace X
EJB Electrical Junction Box X
EMS Electrical Monitoring System Parent X
EPP Electric Power Pack X
ESS Electrical Substation Parent X
FAP Fire Alarm Panel Parent X
FCP Fire Call Point X
FOP Fibre Optic Panel X
GEN Generator Parent if stand alone X
HFT Harmonic Filter X
HMI Human Machine Interface X
HRN Horn / Hooter X
HTP Heat Tracing Panel X
IJB Instrument Junction Box X
IND Indicating Light Tower X
IOP I/O Panel X
IPT Potential Transformer X
ITF Instrument/Control Transformer X
ITP Instrumentation Panel Parent X
IXR Isolating Transformer Parent if stand alone X
LCS Local Control Station X
LCT Load Isolating Contactor X
Fibre Optic Breakout Terminal
LFP (FOBOT)
LIG Light Pole X
LSW Load Break Switch X
LTF Lighting Transformer Parent if stand alone X
OT LLC EQUIPMENT NUMBERING PROCEDURE Page 24 of 29 0000-00-PRC-0055 Rev.1
LTP Lighting Panel X
MCC Motor Control Centre Parent if stand alone X
MIE Miscellaneous Electrical X
MSS Substation - Skid Mounted Parent
MST Motor Starter X
MTE Mine Telephone
MTR Motor X
NER Neutral Earth Resistor X
OHL Overhead Line X
Power Distribution Panel 0.1 To 1kv
PDP (Low Voltage) Parent if stand alone X
PLC Programmable Logic Control Panel Parent X
PRP Power Relay Panel Parent X
RCT Rectifier X
RMU Ring Main Unit X
SAR Surge Arrester
SCR Silicon Controlled Rectifier X
SGA Surge Arrester X
SRD Motor Starter Panel
SRM Electrical Switch room Parent X
SUB Substation Parent X
SVC Static VAR Compensator X
Switchgear 1 to 35kV (Medium
SWG Voltage) X
SWP Switchgear 35 to 230kV (High Voltage) Parent X
TOW Power Transmission Tower Parent X
TRN Transmission Line
TSS Transportable Substation Parent X
UDP Ups Power Distribution Panel X
UPS Uninterruptable Power Supply X
VDO Voice / Data Outlet
VFD Variable Frequency Drive X
WLD Welding Receptacle X
WSC Wave Shaping Capacitor X
Small Power Distribution Panel (Light
XDR And Power) Parent X
XMR Transformer Parent if stand alone X
YTX Camera X

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 25 of 29 0000-00-PRC-0055 Rev.1


APPENDIX C: TELECOMMUNICATION CODE LIST
MANDATORY CODES
FOR
CODE EQUIPMENT DESCRIPTION PARENT CLASSIFICATION
UNDERGROUND
PROJECT HNL1
ACR Card Reader X
ACS Access Control System X
FOC Fibre Patch Cable X
FPP Fibre Optic Patch Panel
ICT ICT RACK X
IDV Telephone Data and TV Outlet X
JBT Junction Box Telecommunication X
LLS Network Switch X
NJC UTP Patch Cord X
NVR Network Video Recorder X
ETE Emergency Telephone X
WAP Wireless Access Point X

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 26 of 29 0000-00-PRC-0055 Rev.1


APPENDIX D: INSTRUMENTATION IDENTIFICATION LETTERS
Table 1 - ANSI/ISA-5.1 Typical Letter Combinations
First Letter (4) Succeeding Letters (3)
Readout or
Measured or Output
Modifier Passive Modifier
Initiating Variable Function
Function
A Analysis Alarm
B Burner, Combustion User's Choice User's Choice User's Choice
C User's Choice Control
D User's Choice Differential
Sensor (Primary
E Voltage
Element)
F Flow Rate Ratio (Fraction)
Glass, Viewing
G User's Choice
Device
H Hand High
I Current (Electrical) Indicate
J Power Scan
Time, Time Time Rate of
K Control Station
Schedule Change
L Level Light Low
Middle,
M User's Choice Momentary
Intermediate
N User's Choice User's Choice User's Choice User's Choice
Orifice,
O User's Choice
Restriction
Point (Test)
P Pressure, Vacuum
Connection
Q Quantity Integrate, Totalize
R Radiation Record
S Speed, Frequency Safety Switch
T Temperature Transmit
U Multivariable Multifunction Multifunction Multifunction

Vibration, Valve, Damper,


V
Mechanical Analysis Louver

W Weight, Force Well


X Unclassified X Axis Unclassified Unclassified Unclassified
Event, State or Relay, Compute,
Y Y Axis
Presence Convert
Driver, Actuator,
Z Position, Dimension Z Axis Unclassified Final
Control Element

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 27 of 29 0000-00-PRC-0055 Rev.1


APPENDIX E: CONTROL SYSTEM ACTUATED VALVE TYPE CODE
Table 2 - ANSI/ISA-5.1 Typical Letter Combinations
Readout Switches and Alarm
Controllers Devices Devices* Transmitters

Viewing Device, Glass


First-Letters

Computing Devices
Solenoids, Relays,

Primary Element
Control Valves

Well or Probe

Final Element
Self-Actuated

Safety Device
Recording

Recording

Recording

Test Point
Indicating

Indicating

Indicating
High**
Initiating or

Comb
Blind

Blind
Low
Measured Variable
A Analysis ARC AIC AC AR AI ASH ASL ASHL ART AIT AT AY AE AP AW AV

B Burner/Combustion BRC BIC BC BR BI BSH BSL BSHL BRT BIT BT BY BE BW BG BZ

C User's Choice
D User's Choice
E Voltage ERC EIC EC ER EI ESH ESL ESHL ERT EIT ET EY EE EZ
FRC FIC FC FCV, FR FI FSH FSL FSHL FRT FIT FT FY FE FP FG FV
F Flow Rate FICV
FQ Flow Quality FQRC FQIC FQR FQI FQSH FQSL FQIT FQT FQY FQE FQV

FF Flow Ratio FFRC FFIC FFC FFR FFI FFSH FFSL FE FFV

G User's Choice
H Hand HIC HC HS HV

I Current IRC IIC IR II ISH ISL ISHL IRT IIT IT IY IE IZ

J Power JRC JIC JR JI JSH JSL JSHL JRT JIT JT JY JE JV

K Time KRC KIC KC KCV KR KI KSH KSL KSHL KRT KIT KT KY KE KV

L Level LRC LIC LC LCV LR LI LSH LSL LSHL LRT LIT LT LY LE LW LG LV

M User's Choice
N User's Choice
O User's Choice
PRC PIC PC PCV PR PI PSH PSL PSHL PRT PIT PT PY PE PP PSV, PV
P Pressure/Vacuum PSE
PD Pressure, Differential PDRC PDIC PDC PDCV PDR PDI PDSH PDSL PDRT PDIT PDT PDY PE PP PDV

Q Quantity QRC QIC QR QI QSH QSL QSHL QRT QIT QT QY QE QZ

R Radiation RRC RIC RC RR RI RSH RSL RSHL RRT RIT RT RY RE RW RZ


S Speed/Frequency SRC SIC SC SCV SR SI SSH SSL SSHL SRT SIT ST SY SE SV

T Temperature TRC TIC TC TCV TR TI TSH TSL TSHL TRT TIT TT TY TE TP TW TSE TV

Temperature, TDRC TDIC TDC TDCV TDR TDI TDSH TDSL TDRT TDIT TDT TDY TE TP TW TDV
TD Differential
U Multivariable UR UI UY UV

Vibration/Machinery VR VI VSH VSL VSHL VRT VIT VT VY VE VZ


V Analysis
W Weight/Force WRC WIC WC WCV WR WI WSH WSL WSHL WRT WIT WT WY WE WZ

Weight/Force, WDRC WDIC WDC WDCV WDR WDI WSDSH WDSL WDRT WDIT WDT WDY WE WDZ
WD Differential
X Unclassified
Y Event/State/Presence YIC YC YR YI YSH YSL YT YY YE YZ

Z Position/Dimension ZRC ZIC ZC ZCV ZR ZI ZSH ZSL ZSHL ZRT ZIT ZT ZY ZE ZV


ZDRC ZDIC ZDC ZDCV ZDR ZDI ZDSH ZDSL ZDRT ZDIT ZDT ZDY ZDE ZDV
ZD Gauging/Deviation
Note: This table is not all-inclusive. Other Possible Combinations:
*A, alarm, the annunciating device, may be used in the same FO (Restriction Orifice) PFR (Ratio)
fashion as S, switch, the actuating device. FRK, HIK (Control Stations) KQI (Running Time Indicator)
FX (Accessories) QQI (Indicating Counter)
**The letters H and L may be omitted in the undefined case. TJR (Scanning Recorder) WKIC (Rate-of-Weight-Loss Controller)
LLH (Pilot Light) HMS (Hand Momentary Switch)

OT LLC EQUIPMENT NUMBERING PROCEDURE Page 29 of 29 0000-00-PRC-0055 Rev.1