CONSTRUCTION NOTES AND SPECIFICATIONS

ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE


EXECUTED ACCORDING TO THE REQUIREMENTS OF THE
PHILIPPINE PLUMBING CODE AND RULES AND REGULATIONS
OF THE GOVERNMENT.
2 3
COORDINATE DRAWING WITH OTHER RELATED DRAWINGS
AND SPECIFICATION, THE ENGINEER SHALL BE NOTIFIED
IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.

PIPE SHALL BE INSTALLED AS INDICATED ANY RELOCATION


REQUIRED FOR THE PROPER EXECUTION OF OTHER
TRADES SHALL BE SUBJECT TO THE APPROVAL OF THE
ARCHITECT AND OR ENGINEER.
W6

DS DS
ALL SLOPE FOR HORIZONTAL BRANCHES (SEWER) SHALL
CABINET FAU.
FAU. FAU. CABINET MAINTAIN 1% AS MINIMUM UNLESS OTHERWISE INDICATED
QUARTER'S SHO.
QUARTER'S AREA 2 LAUNDRY USE UNIDEX S-1000 UPVC OR SANIMOLD TO WET.
WALK IN

CABINET
AREA 1 LINEN AREA AREA BATH W.C.
W6
TAB CLOSET
D5 D2
T&B DN 2" DIAMETER FOR LAVATORY, SINK, URINAL, AND
D6
D5 WM VENTILATION
FAU.
D6
DN W5
4" DIAMETER FOR WATER CLOSET, SHOWER, DRAIN,

TERRACE
RANGE MAIN VENT STACK PIPE, AND

KITCHEN
MASTER

COUNTER
BEDROOM SLOPE SINK.

DIRTY
KITCHEN

CABINET
BAR
FAU.

SINK
FAU.
LANAI DINING AREA
D4 REF. D4 USE 21" POLYPROPYLENE RANDOM (PPR) PIPE FOR ALL
BEDROOM 2 SUPPLY LINES
D2
D5
ALL PLUMBING WORKS SHALL BE DONE UNDER THE DIRECT
PANTRY D3 OR IMMEDIATE SUPERVISION OF A DULY LICENSED
D3
CABINET SANITARY ENGINEER OR MASTER PLUMBER.
UP

FAU.
STO. 6 5 4 3 2 1 STAIR STAIR FAU.
FAU. W4 FAU.
3 2 1 10 11 12 13 14 15 16
COMMON W3
9
HALLWAY COMMON W3

DN
DN

D5 D6
T&B D6
T&B

CABINET CABINET

HALLWAY
DS

D3 D3

GUEST
LIVING AREA LEGEND:
BEDROOM BEDROOM 1

CANOPY
CARPORT
OPEN AREA
ALL

ALL

DN
FIREW

FIREW
W5 W7
D7
D1

TERRACE
W1 W2
DS

W1 W2 CANOPY
UP

1 4

A SECOND FLOOR WATER LINE LAYOUT


A GROUND FLOOR WATER LINE LAYOUT 1 1 SCALE : 1 :100 MTS
1 1 SCALE : 1 :100 MTS

ARCHITECTURAL FIRM PROJECT TITLE PROJECT OWNER SHEET CONTENT REVISIONS RA 9266 ARTICLE 4 SECTION 33 SHEET NO.

GROUND FLOOR PLAN Drawings and specifications and other contract documents duly signed,
PROPOSED 2 - STOREY RESIDENTIAL BUILDING SECOND FLOOR PLAN stamped or sealed, as instruments of service, are the intellectual property
and documents of the architect, whether thE object for which they are made
is executed or not. It shall be unlawful for any person to duplicate or to make
copies of said documents for use in the repetition of and for other projects or
P-1
buildings, whether executed partly or in whole, without the written consent of
architect or author of said documents.