HERMON LABORATORIES
68 Hatachana Street
(Postal Mail to P.O. Box 23)
Binyamina, 3055001, ISRAEL
Mr. George Shleimovich Phone: 972 4 6288 001
Email: mail@hermonlabs.com
CALIBRATION
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations1, 8:
AC Voltage – Generate
AC Voltage – Generate
(cont)
AC Voltage – Measure
AC Voltage – Measure
(cont)
AC Current – Generate
AC Current – Generate
(cont)
AC Current – Measure
AC Current – Measure
(cont)
AC High Voltage –
Measure
DC High Voltage –
Measure
Biconical Antenna –
ANSI C63.5-1998 (SSM)
3m (30 to 300) MHz 1.5 dB
ANSI C63.5-1998 (SSM)
10 m (30 to 300) MHz 1.5 dB ANSI C63.5-2006,
excluding Appendix H
Antenna Factor, (RAM)
(Horizontal Polarization)
Dipole Antenna –
Antenna Factor,
(Horizontal Polarization)
Hybrid Broadband
Antenna –
3m (30 to 3000) MHz 1.5 dB ANSI C63.5-1998 (SSM)
Horn Antennas –
Linear Polarized
Broadband Antennas –
HP 4195A
Line Impedance
Stabilization Network
(LISN) –
Voltage Division Factor (0.009 to 400) MHz 0.09 dB HIOKI 3532-50 LCR
HiTESTER,
Isolation (0.009 to 400) MHz 0.70 dB HP 4195A, HP41951A,
Agilent 85032E
Coupling Decoupling
Network (CDN) –
150 Ω to 50 Ω adapters –
Impedance stabilization
network (ISN)
Impedance Magnitude ((0.1 to 230) MHz 1.9 % CISPR 16-1-2, CISPR 22,
(230 to 400) MHz 2.6 % CISPR 32
RF Power – Measure
RF Power – Measure
(cont)
(-90 to -20) dBm 10 Hz to 100 MHz 2.8 % + M Rohde & Schwarz NRP-
(Absolute) (0.1 to 8) GHz 3.3 % + M Z56, Agilent E4446A
(8 to 12.4) GHz 5.3 % + M
(12.4 to 33) GHz 5.6 % + M
(33 to 40) GHz 7.4 % + M
RF Power – Measure
RF Power – Linearity
(relative power)
Frequency readout 9 kHz to 40 GHz 0.2 µHz/Hz Rohde & Schwarz SMB-
accuracy 100A / SML3
Frequency span accuracy 9 kHz to 40 GHz 0.35 % Rohde & Schwarz SMB-
100A / SML3, Keysight
N5173B
Sweep time accuracy
100 µs to 10 s 0.35 % Rohde & Schwarz SMB-
100A / SML3, Tabor
Electronics WW5062
Residual FM
Up to 350 Hz 10 %
Third order
intermodulation distortion 1 MHz to 40 GHz 0.59 dB Rohde & Schwarz SMB-
(TOI) 100A, Keysight N5173B
Gain compression
1 MHz to 40 GHz 0.06 dB
Noise Sidebands (Phase 10 MHz to 3 GHz 0.6 dB Rohde & Schwarz SMB-
Noise) 100A
RF Power – Generate
(-55 to 20) dBm 9 kHz to 2.4 GHz 1.7 % + M Rohde & Schwarz
(2.4 to 4) GHz 2%+M SML03, SMB100A,
(4 to 8) GHz 3.8 % + M NRP-Z91, & NRP-Z31
(8 to 26.5) GHz 5.5 % + M
(26.5 to 33) GHz 8.4 % + M
(-80 to -20) dBm 10 Hz to 100 MHz 2.8 % + M Rohde & Schwarz NRP-
(0.1 to 2.4) GHz 3.0 % + M Z56, Agilent E4446A
(2.4 to 8) GHz 3.3 % + M
(8 to 12) GHz 4.0 % + M
(12 to 18) GHz 4.5 % + M
(18 to 26.5) GHz 5.3 % + M
(26.5 to 40) GHz 7.8 % + M
Transmission –
Magnitude
(Attenuation / Gain)
Reflection Magnitude –
Reflection Magnitude –
(cont)
Impedance – Measure,
Magnitude
(1 to 2) Ω 0.47 %
(2 to 3) Ω 0.38 %
(3 to 4) Ω 0.36 %
(4 to 5) Ω 0.33 %
(5 to 6) Ω 0.31 %
(6 to 7) Ω 0.29 %
(7 to 8) Ω 0.27 %
(8 to 9) Ω 0.25 %
(9 to 10) Ω 0.24 %
Impedance – Measure,
Magnitude (cont)
Impedance – Measure,
Magnitude (cont)
(1 to 2) Ω 0.47 %
(2 to 3) Ω 0.38 %
(3 to 4) Ω 0.36 %
(4 to 5) Ω 0.33 %
(5 to 6) Ω 0.31 %
(6 to 7) Ω 0.29 %
(7 to 8) Ω 0.27 %
(8 to 9) Ω 0.25 %
(9 to 10) Ω 0.24 %
(1 to 2) kΩ 0.33 %
(2 to 3) kΩ 0.24 %
(3 to 4) kΩ 0.25 %
(4 to 5) kΩ 0.25 %
(5 to 6) kΩ 0.26 %
(6 to 7) kΩ 0.27 %
(7 to 8) kΩ 0.29 %
(8 to 9) kΩ 0.3 %
(9 to 10) kΩ 0.31 %
Impedance – Measure,
Magnitude (cont)
(1 to 2) Ω 1.2 %
(2 to 3) Ω 1.1 %
(3 to 4) Ω 0.99 %
(4 to 5) Ω 0.88 %
(5 to 6) Ω 0.79 %
(6 to 7) Ω 0.69 %
(7 to 8) Ω 0.61 %
(8 to 9) Ω 0.55 %
(9 to 10) Ω 0.50 %
(10 to 20) Ω 0.47 %
(20 to 30) Ω 0.47 %
(30 to 40) Ω 0.45 %
(40 to 50) Ω 0.43 %
(50 to 60) Ω 0.41 %
(60 to 70) Ω 0.39 %
(70 to 80) Ω 0.38 %
(80 to 90) Ω 0.37 %
(90 to 100) Ω 0.36 %
Impedance – Measure,
Magnitude (cont)
Impedance – Measure,
Magnitude (cont)
(5 to 150) Ω 1.9 %
(150 to 600) Ω 2.3 %
(600 to 1200) Ω 2.9%
(1200 to 2000) Ω 4.8 %
(5 to 150) Ω 2%
(150 to 600) Ω 3.1 %
(600 to 1200) Ω 4.5 %
(1200 to 2000) Ω 8.5 %
Impedance – Measure,
Phase
(0 to ± 180) °
(1 to 2) Ω 0.30 °
(2 to 3) Ω 0.27 °
(3 to 4) Ω 0.25 °
(4 to 5) Ω 0.24 °
(5 to 6) Ω 0.22 °
(6 to 7) Ω 0.21 °
(7 to 8) Ω 0.20 °
(8 to 9) Ω 0.19 °
(9 to 10) Ω 0.18 °
Impedance – Measure,
Phase (cont)
(1 to 2) kΩ 0.08 °
(2 to 3) kΩ 0.06 °
(3 to 4) kΩ 0.06 °
(4 to 5) kΩ 0.07 °
(5 to 6) kΩ 0.07 °
(6 to 7) kΩ 0.07 °
(7 to 8) kΩ 0.07 °
(8 to 9) kΩ 0.08 °
(9 to 10) kΩ 0.08 °
(1 to 2) MΩ 0.30 °
(2 to 3) MΩ 0.33 °
(3 to 4) MΩ 0.39 °
(4 to 5) MΩ 0.48 °
(5 to 6) MΩ 0.58 °
(6 to 7) MΩ 0.68 °
Impedance – Measure,
Phase (cont)
(7 to 8) MΩ 0.79 °
(8 to 9) MΩ 0.90 °
(9 to 10) MΩ 1.2 °
(1 to 2) kΩ 0.24 °
(2 to 3) kΩ 0.10 °
(3 to 4) kΩ 0.11 °
(4 to 5) kΩ 0.12 °
(5 to 6) kΩ 0.14 °
(6 to 7) kΩ 0.16 °
(7 to 8) kΩ 0.18 °
(8 to 9) kΩ 0.20 °
(9 to 10) kΩ 0.22 °
Impedance – Measure,
Phase (cont)
Impedance – Measure,
Phase (cont)
(1 to 2) kΩ 0.29 °
(2 to 3) kΩ 0.18 °
(3 to 4) kΩ 0.19 °
(4 to 5) kΩ 0.20°
(5 to 6) kΩ 0.21 °
(6 to 7) kΩ 0.22 °
(7 to 8) kΩ 0.24 °
(8 to 9) kΩ 0.25 °
(9 to 10) kΩ 0.27 °
Impedance – Measure,
Phase (cont)
III. Thermodynamics
1
This laboratory offers commercial calibration service only.
2
Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to
influences from the circumstances of the specific calibration.
3
In the statement of CMC, M is the Mismatch error due to connections of calibrated device to calibration
set up in actual use.
4
In the statement of CMC the percentage is defined as percent of reading.
5
Laboratory calibrations are to the current revision/configuration of the applicable standard. Calibration
to earlier version or revision of the standard can be provided on request.
6
The Frequency marker count accuracy utilizes a Synthesized Sweeper that is phase locked to the DUT and
the frequency error is eliminated.
7
The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8
This scope meets A2LA’s P112 Flexible Scope Policy.
HERMON LABORATORIES
Binyamina, Israel
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General
requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of
ANSI/NCSL Z540-1-1994 and R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation
demonstrates technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0839.03
Valid to May 31, 2023