LCD Television

Technical Bulletin Sharp Electronics Corporation


Services and Solutions Group
1300 Naperville Drive
Romeoville, IL 60446

Number: LCDTV-269 Date: November 2009

Model(s): LC52E77UN(A)
Subject: No Power and Power LED is flashing 1X

Symptom: TV will not turn on and front indicator LEDs are flashing. TV may in some cases come on
and exhibit flashing backlights. Most commonly occurs when the TV is used for the very first time. 

Cause: One or both of the Inverter Units is not fully seated.


(RUNTKA528WJN1 TOP / RUNTKA529WJN1 BOTTOM)

Solution: Properly seat the Inverter Unit(s) fully into a locked position.
 

Steps to Repair:   
1) Refer to disassembly procedure for Rear Cabinet as described in Service Manual 
2) Examine both Inverter Units to see if they are improperly installed.  (See FIGURE 1) 
3) If either or both Inverter Units are not properly seated please apply minimal force onto PWB, nearest the 
clips, to lock it into place.  (See FIGURE 2) 
Steps to Reset: 
4) Hold in INPUT & VOLUME DOWN buttons on the TV 
5) Continue to hold in the buttons and plug in the TV 
6) TV will turn on by itself and a small “K” will now be present on the screen in the upper left 
7) Release both buttons 
8) Simultaneously press CHANNEL DOWN & VOLUME DOWN one time on the TV 
9) Service Menu should now be showing 
10) If “LAMP ERROR” shows other than a Zero please reset it (Refer to Service Menu Detailed Instructions Page 4)
11) If Monitor Error Cause is other than ZERO please reset it (Refer to Service Menu Detailed Instructions Page 4) 
12) Perform Industry Init (Refer to Service Menu Detailed Instructions Page 4) 
13) Unplug the TV upon completion of Industry Init (green screen) 
14) Wait 30 seconds and plug in TV 
Steps to Test: 
15) Check the TV for functionality and POWER ON / OFF several times 
16) Unplug the TV after testing is successful 
17) Repeat steps 4 thru 9 to ensure that no errors are present 
 

Bulletin # LCDTV-269 Page 1 of 4


Rear of the Disassembled TV

INVERTER UNITS

FIGURE 1

Bulletin # LCDTV-269 Page 2 of 4


FIGURE 2

Bulletin # LCDTV-269 Page 3 of 4


Service Menu Detailed Instructions 
 
 
Lamp Error Reset 
1) Service Menu screen should be showing on the screen 
2) Using the remote control, press the Down Select Arrow button one time (button is under ENTER) 
3) The upper left corner of the service menu screen should indicate “2/41” 
4) Use the Channel Down button on the remote to highlight the line “LAMP ERROR RESET       OFF” 
5) Use the Volume Up button on the remote to change the “OFF” to “ON” and press ENTER button 
6) The error is now reset 
 
Monitor Error Cause Reset 
1) Service Menu screen should be showing on the screen 
2) Using the remote control, press the Up Select Arrow button five times (button is above ENTER) 
3) The upper left corner of the service menu screen should indicate “37/41” 
4) Use the Channel Down button on the remote to highlight the line “MONITOR ERROR CAUSE RESET       OFF” 
5) Use the Volume Up button on the remote to change the “OFF” to “ON” and press ENTER button 
6) The error is now reset 
 
Industry Init 
1) Service Menu screen should be showing on the screen 
2) Using the remote control, press the Down Select Arrow button one time (button is under ENTER) 
3) The upper left corner of the service menu screen should indicate “2/41” 
4) Use the Channel Down button on the remote to highlight the line “INDUSTRY INIT       OFF” 
5) Use the Volume Up button on the remote to change the “OFF” to “ON” and press ENTER button 
6) The line “INDUSTRY INIT    ON” will change to “//////////////” briefly 
7) When Industry Init  is complete the screen will be green 

Bulletin # LCDTV-269 Page 4 of 4