Ballast Water Treatment System BWTS PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Ballast Water Treatment System » Company Profiles

03
HANLA IMS
Ballast Water Treatment System
& 3B Package Solution

Leading Company
in Marine & Offshore with World's Best Technology
for Customer Satisfaction

2015 ∙ New Excellent Technology Authentication


∙ High technology product confirmation
∙ World Class 300 Company' Certificate of Designation
∙ Next Global Champ Certificate of Designation
∙ Type Approval Certificate of Ballast Water Treatment System
2014 ∙ Leading Company Certificate (Marine Industry)
∙ Korean World-Class Product Award
∙ Certificate of Designation as an Advanced Technology Center
since 1989 2013 ∙ OEM/ ODM Agreement with Econosto
∙ EcoGuardian(BWTS) IMO final approval
∙ INNO-BIZ Certificate

Instrument Division 2012 ∙ Global Small Giants selection 2012 Leading Employer Award
(Busan Metropolitan City)
Cargo Monitoring System (Radar/ Float)
Tank Remote Sounding System (Pneumatic/ Elec.Pressure) 2011 ∙ Certified by ISO 14001 of EMS and QMS
Hi & Hi-Hi Level Alarm System (Acoustic wave/Float) 2010 ∙ Start business Ballast Water Treatment System
Fixed Gas Sampling System ∙ LED lighting certified by KS Mark
Gas Detection & Analyzing System
Vapour Emission Control System 2009 ∙ Change name to HANLA IMS
Water Ingress Detection System ∙ Acquired equity in Blue Science Co., Ltd
Water Survey Detection System
Temperature/ Pressure Sensors 2008 ∙ Start business Valve Remote Control System
Level Transmitters ∙ Established affiliated company HANLA NMT
Level Gauges 2007 ∙ Established China Corporation HANLA M&E CO.,LTD
Level Switches ∙ Listed on Korean Stock Market
Oil Sampler 2005 ∙ Awarded Q-GOLD MARK Certification from Samsung Heavy Industries
Indicators ∙ Awarded an export prize.(10,000,000 USD)
System Division 2004 ∙ Awarded an export prize(5,000,000 USD)
Valve Remote Control System 2002 ∙ Established a Joint-Venture Company “TAIZHOU HANVI INSTRUMENT CO., LTD“
(Hydraulic / Electric / Pneumatic / Electro Hydraulic)
2000 ∙ CE mark Certified from DNV
Contents
Loading Computer
Dynamic A (Integrated Control & Monitoring System) Company Profiles 03
1995 ∙ ISO 9001 Certified from DNV Introduction 05
Environment Division ∙ Registered on Manufacturer List of Korea Electric Power Corporation
Ballast Water Treatment System (EcoGuardian™) Process 07
1993 ∙ Products type approved from
Plant Water Treatment System ∙ – ABS, KR, LR, DNV, BV, GL, NK, RINA Installation Solution 09
LED Division 1992 ∙ Technical Agreement with Honeywell Marine System 3B Package Solution 10
LED Lighting ∙ Representative Agreement with VEGA Germany Global Service Network 13
LED Lamp 1989 ∙ HANLA LEVEL established

Manufacturing Line Authorized by the Quality


Ballast Water Treatment System » Introduction
05
HANLA IMS
Ballast Water Treatment System
& 3B Package Solution

INTRODUCTION General Information COMPONENT


Hanla IMS Co.,Ltd has developed eco-friendly EcoGuardian™ system for treating
Aquatic Invasive Species in a ship’s ballast water. Treatment method is side-
Stream type which enables the system to be remotely installed away from AFU ECU
the ballast lines. The EcoGuardian™ system can be installed separately by unit. Automatic Filter Unit Electro Chlorination Unit
So relocation of other equipments and additional engineering can be minimized.
Remove particles larger than 50µ Solution :
Basket Screen Type Sodium hypochlorite (NaOCl)
Division Description Capacity : 130 ~ 3,000㎥/hr Capacity : 130 ~ 6,000㎥/hr
Differential pressure Flowrate : 1~2% from main stream
Treatment Method Ballasting
for backflushing : 0.5 bar H2 Treatment :
Filtration (50㎛) + Electrolysis (Side-stream) Separate by degassing system
Pressure drop : 0.1 bar (In general)
De-ballasting
Neutralization (Sodium thiosulfate)
Biological Efficiency Compliance with IMO D2 performance standard 01 02
02
Operation Mode Automatic / Manual by remote control panel
Operation H/W, S/W Human Machine Interface(HMI), Touch Screen
02 Electro
Utility Required 1. Control air (6~7kgf/cm2) for pneumatic valves Chlorination Unit
2. Fresh water for rectifier cooling Main Control Panel 04
Installation type 1. Skid mounted / 2. Containerized / 3. Separate

Type and Dimention (Detail dimension will be changed on a case by case basis)

Capacity SIZE : L x W x H (mm) Power


Model Consumption
[m3/h] AFU ECU NEU [kW] Neutralization 03 01 Filter
EG0130 Unit
130 1550 x 1400 x 1200 900 x 1000 x 1350 5.1
EG0130-Ex
750 x 900 x 1700
EG0250
250 1750 x 1450 x 1400 1050 x 1150 x 1600 10.3
EG0250-Ex
EG0350
350 1900 x 1600 x 1550 14.4
EG0350-Ex
900 x 1100 x 2070 1250 x 1350 x 1900
EG0500
500 1900 x 1650 x 1600 20.6
EG0500-Ex
EG0800
800 1200 x 1300 x 2100 1450 x 2750 x 1750 1400 x 1500 x 2100 30.8
EG0800-Ex
EG1000
1000 1700 x 1800 x 2600 1750 x 2570 x 1800 41.1
EG1000-Ex 03 04
1500 x 1600 x 2300
EG1500 NEU MCP
1500 2250 x 2200 x 2800 1500 x 3300 x 1800 61.7
EG1500-Ex
Neutralization Unit Main Control Panel
EG2000
2000 2250 x 2200 x 3050 1700 x 3300 x 2850 1600 x 1700 x 2400 82.2 The de-ballast water is neutralized A control system consists of a main
EG2000-Ex
EG2600 by the NEU prior to discharging control panel and Human Machine
2600 2750 x 2600 x 3100 2300 x 3800 x 2850 102.8 overboard with the least amount Interface (HMI).
EG2600-Ex
1700 x 1750 x 2550 of sodium thiosulfate through It helps a user operate and control
EG3000
3000 2750 x 2600 x 3300 2300 x 3900 x 2300 123.4 monitoring of TRO unit. EcoGuardian™ in an easy and
EG3000-Ex simple way.
EG4000
4000 2250 x 4400 x 3050 2750 x 3350 x 2800 1750 x 1850 x 2650 164.4
EG4000-Ex
EG6000
6000 2750 x 5200 x 3300 2750 x 3550 x 3050 1900 x 1950 x 2850 246.6
EG6000-Ex
* Power consumption condition: 20 °C, 34 PSU

Manufacturing Line Authorized by the Quality


Ballast Water Treatment System » Process
07
HANLA IMS
Ballast Water Treatment System
& 3B Package Solution

PROCESS Advantage
EcoGuardian ™ is based on the principles of pre-filtration and electrolysis. 1 / Simple & Easy Installation 2 / Minimum modification of 3 / Effective even in the 4 / No corrosion to hulls & pipings
existing ballasting main line turbid water
5 / No stock of dangerous 6 / Cost-effective by Hanla 7/ Effective disinfection 8 / Low maintenance cost
chemicals package solution

1st STEP Mechanical Filtering 2nd STEP Electrolysis Disinfection Ballasting


Precise Filtration
; Filtration (50um) + Electrolysis (Side-Stream)

Deballasting
Neutralization Unit
Decrease Total Residual Oxidants(TRO) value Reliable Neutralization (Sodium thiosulfate)
; Real-time monitoring by TRO sensor through
Hanla Integrated ballast control system.
below 0.2ppm

Deballasting Ballast
Filter Unit max. 9 ppm Tank EcoGuardian™ Key Features
Remove particles or ∙ Automatic backflushing filter unit removes large organisms and solid particles above 50 µm;
Ballasting ∙ Automatic backflushing operation starts when the pressure difference between the water inlet and outlet reaches a certain value;
organisms larger than 50㎛
∙ The side stream of the ballasting water goes through the electrolysis unit that generates the high concentration of
TRO (Total Residual Oxidants). The concentrated stream is then injected back to the main ballasting line;
∙ Electrolysis unit (including electrolytic cells, rectifier/transformer, booster pumps, conductivity sensor and degassing devices)
Electrolyzer Unit
produces sodium hypochlorite solution in situ which disinfects the residual planktons, pathogens, larva or spores;
Disinfect virus, pathogenic bacteria and
∙ Neutralization unit adds sodium thiosulfate solution into the treated ballast water to neutralize the residual TRO during de-ballasting;
other organisms smaller than 50㎛
∙ When ballasting maximum TRO concentration is limited to 9.0 mg/L;
∙ When de-ballasting MADC (Maximum Allowable Discharge Concentration) is 0.2 mg/L TRO as Cl2;
∙ Control system including PLC, HMI and auxiliary equipment

BALLASTING DE-BALLASTING

Abbr. Description
Hydrogen gas (to the exposed area)

AFU Auto Filter Unit


ECU Electrochlorination Unit
NEU Neutralization Unit
TSU TRO Sensor Unit
SP Sampling Port

Manufacturing Line Authorized by the Quality


Ballast Water Treatment System » Installation Solution
09
HANLA IMS
Ballast Water Treatment System
& 3B Package Solution

INSTALLATION SOLUTION
This sideline type electrolysis system can be constructed in a small size. Also due to the characteristics of system
which
whic uses active substance as disinfectant, our system can be easily modularized and scalable.
So our system can be installed easily with low cost even in retrofit. In some cases if needed, our system can be seated
c
on the skid mount or containerized for easy transportation and installation.

Submerged pumps Pump room

Side stream line

Side stream line

Retrofit Solution Approval Status


E

MARINE ENVIRONMENT PROTECTION MEPC 66/INF.2


COMMITTEE 29 October 2013
66th session ENGLISH ONLY
Agenda item 2

HARMFUL AQUATIC ORGANISMS IN BALLAST WATER

List of ballast water management Guidelines, guidance documents


and approved ballast water management systems

Note by the Secretariat

SUMMARY

Executive summary: This document intends to provide comprehensive information with


regard to Guidelines, guidance documents and circulars related to
the BWM Convention. This document also presents information on
approved ballast water management systems.

Strategic direction: 7

High-level action: 7.1.2

Planned output: 7.1.2.4

Action to be taken: Paragraph 6

Related document: MEPC 64/23

Background

1 At its sixty-fourth session, the Committee agreed to request the Secretariat to


consider the possibility of compiling the Guidelines for the uniform implementation of
the BWM Convention and other relevant guidance documents, to be made available on
the IMO website.

2 The Secretariat has made a list of the relevant Guidelines and guidance documents,
including links to the original documents, available on the Organization's website
at http://www.imo.org/OurWork/Environment/BallastWaterManagement. The full list is set
out in annex 1 for ease of reference.

3 The "Ballast Water Management" page of the Organization's website also contains a list
of ballast water management systems that make use of Active Substances which have
Piping diagram Design Drawing (for owner) Working for installation place received Basic or Final Approval in accordance with the Procedure for approval of ballast water
management systems that make use of Active Substances (G9) (resolution MEPC.169(57)).
Pre The list includes a table of ballast water management systems which have received

and Installation I:\MEPC\66\INF-2.doc

-Survey Port Status Drawing (for class) Loading on board


Manufacturing
P & ID Purchase of Material Installation of EcoGuardian™
Scope of Supply Manufacturing Pipe working Approved Approved EX-PROOF type Approved EX-PROOF type
2013 2015 Approved 2015 2015 Approved 2015
Inspection Cable working
Delivery Sea Trial
(under processing)
On Board
Main 3D Scannaing
Survey Proposal with cost

Manufacturing Line Authorized by the Quality


Ballast Water Treatment System » 3B Package Solution
12
HANLA IMS
™ Ballast Water Treatment System
& 3B Package Solution

is the only company which can provide


What is the difference of the HANLA's 3BALLAST™ ?
"Integrated Triple Ballast Package Solution"
developed by our own technologies throughout the world Since star
starting
ting a bus
business
iness in m
marine
arine equipment
equipment industry
industry in 19
1989,
89, w
we
e “HA
“HANLA
NLA IMS”
IMS” have
have ssupplied
suppli
upplied
upplied re
reliabl
reliable
liable
liable pro
products
ducts to ccustom
customers
ustomers
ustom ers ffor Individual Hanla Package
over 26 years.
years. Based on these
these 26 years
years experiences,
e
experi
xperiences
xperiences,, Loading
ences Loading Computer,
Computer, Tank Monitoring
Monitoring System,
System, Valve
Valve Remote
Remote Control
Control System,
Syste
Ballast
Ballast Water
Water Treatment
Treatm
Treatment System(BWTS),
System
S ystem(BWTS
(BWTS),
), LED
LED Lighting
Lighting have been developed
developed by our
our own
own technologies
technolo
tec hnologies
hnolo gies and we
we have
have been
been continuously
continuo
tinuously
usly A B C D
growing
growing up to become
become the best company
company in this field.
field Supply Supply Supply Supply ICMS BWTS
Now, as a specialist
specialist of Total
Total Ballast
Ballast System
System Line Up, all
all of our staff are going to run
run more
more faster
faster with the 3B
3B in their mind.
mind ICMS BWTS VRCS TLGS
This 3B is our new campaign
ccampai
ampaign
ampai gn logo
logo to introduce
introduce that we “HANLA
“HANLA IMS” is a specialist
spec
specialis
ialistt of Total Ballast
ialis Ballast System
System Line Up. VRCS TLGS
World Best
3B ballast
ballast package
package solution
ssoluti
olution
olution has
has been
been created
created base
based highest
d on the highes
highest customer
ighest customer satisfaction
sati
satisfact
sfaction
sfaction and
and we are committed
committed to providing
providi
providing
oviding the
th Commissioning Commissioning Commissioning Commissioning
Ballast Water Treatment System best service
service to our customers
customers with cost-effective
cost-
cost-effec
effective
effective optimal
optimal system.
system. Cost Saving by 3B Package
The 3B
3B means
means not
not only
onl Ballast
Ballast Water
Water Treatment
T
Treatm
reatment
reatm ent System,
S
System
ystem,, Ballast
ystem Ballast Valve Remote
Remote Control
Control System,
System, and
and Ballast
Ballast Tank Gauging
Gauging System
System
Ballast Valve Remote Control but also
also Best
Best quality,
qualit
q uality,
uality, Be
Best
st technology
technol
technology
chnology a
and
nd Be
Best
st service.
se
service
rvice
Increased Cost in Purchase / Commissioning Reliable Integration System

Ballast Tank Gauging System How can the Hanl


Hanla
a 3BALLAST™
3B
3BALLA
ALLAST™
ALLAST™ pack
package
age solu
solution
tion operate
operate systematically?
systema
systematica
tematically?
tically? One Time Delivery
Each of 3B Syst
System
em co
communi
communicates
mmunicates
mmunicates thro
through
ugh a
an
n int
integrated
integrat
egrated
egrated ballast
ballast control
control console
cconsol
onsole
onsole by Dynamic-A.
Dynamic-A. Risk of Integration

Phase1 1B BWTS - BVRC


When ballast
ballast wa
water
ter ttreatm
treatment
reatment system
system (BWTS)
(BWTS) operates,
operate
op erates,
erate s, a balla
ballast
st co
control
ntrol console
console d displays
displa
isplays
isplays operating
op
operati
erating
erating status
status of BWTS.
BWTS. Delay Delivery of Vessel One Stop Service
During the trea
During treatment
treatment,
tment
tment,, all of tthe
he valves
valves can be con
controll
trolled
troll
be controlled ballast va
ed by the ballast valve ccontro
ontroll sys
ontro
lve control system
tem in accordan
accordance
ordan
in accordance with pr
ce with progres
progression
ogression
ogression of BW
BWTS.
TS.
∙ Unified Total Operation
∙ Complicated and inconvenience Process ∙ User-Oriented Sytem
Phase2 2B BVRC - BTGS ∙ Fast and Convenient Intergrated
When treated ballast water flows into ballast tanks, the level of ballast tanks is measured and monitored by the ballast gauging Service
system. And then, its signal goes to the ballast control console. It helps a decision by the signal to open or close of valves.
Optimized process solution that integrates a wide range of marine systems based on Hanla's
advanced technologies
Phase3 3B BTGS - BWTS Optimized 3BALLAST ™ Solution is the answer and we provides the most perfect integrated system.
When the level of ballast tanks becomes maximum height, ballast control console transfers a signal to BWTS for a stop.
BWTS BVRC BTGS Before BWTS startes, ballast gauging system monitors the level of ballast tank.
Ballast Water Treatment System Ballast Valve Remote Control System Ballast Tank Gauging System
Auto Filter Unit Hydrulic/Electric/Electro-hydrulic Actuator Pulse / FMCW Radar Type(Cargo)
Electro Chlorination Unit Hydrulic Power Unit Magnetic Float Type (Cargo)
VRCS TLGS
Main Control Unit Solenoid Valve Cabinet Electro Pneumatic Type (Ballast) ∙ Hydraulic type ∙ Cargo Monitoring System
Neutralization Unit Control Console Electric Pressure Type (Ballast) ∙ Pneumatic type ∙ Ballast & Draft Gauging System
TL
∙ Electric motor type ∙ Gas Sampling/Detection System
S

∙ Electro-Hydraulic type ∙ Independent High Level Alarm System


GS

ICMS (Dynamic-A)
∙ Control Console One Stop Saving ∙ Vapour Emission Control System
VRC

Integrated Ballast Control System ∙ PLC Control Service Cost ∙ Water Ingress Detection System
∙ I.S. Type Sol.valve Cabinet ∙ Loading computer & ICMS
Ballast water treatment control Tank level / temp / press measuring Advanced ∙ Instruments
Guarantee
Valve and pump control and feedback BW
TS

BWTS ∙ Electrolysis type


TLGS(Cargo) TLGS(ballast)
∙ Side-Stream type
Ballast Water Treatment System Ballast Valve Remote Control system Ballast Tank Gauging System ∙ Neutralization unit