Professional Documents
Culture Documents
YT3300RDI5200S Rotork Valve Positioners Datasheet
YT3300RDI5200S Rotork Valve Positioners Datasheet
Layer, with over the bus power, limits current flows so that
30 (1.18)
2–Conduit
2 (0.08)
OUT2 Port
93.1 (3.67)
105.3 (4.15)
OUT1 Port
Sup. Port
26.5 (1.04)
196.8 (7.75) 10 (0.39)
53.5 (2.11)
240 (9.45) 107.8 (4.24)
25
ø50
40
6–M8 Dp. 13
28.5
57 35 23
type
standard adapter
fork type
1 = 20 to 100 mm 2 = M6 x 63L
Sensitivity ±0.2% F.S. 2 = 90 to 150 mm 3 = M8 x 34L
3 = 16 to 30 mm 4 = M8 x 63L
type
Repeatability ±0.3% F.S.
4 = 16 to 60 mm 5 = NAMUR
Below 2 LPM (sup = O.14 Mpa) 5 = 16 to 100 mm
Air Consumption
Below 0.07 CFM (sup = 20 psi) 6 = 90 to 150 mm
70 LPM (sup = O.14 MPa)
Flow Capacity Conduit & Air Connection
2.47 CFM (sup = 20 psi)
Output 1 = G 1/2 - Rc 1/4 (N/A for YT-3350)
Linear, EQ%, Quick Open, User Set (5, 21 Points) 2 = G 1/2 - 1/4 NPT
Characteristics
3 = G 1/2 - G 1/4 (N/A for YT-3350)
Material Aluminium Diecasting Stainless Steel 316 4 = M20 - 1/4 NPT (N/A for YT-3350)
5 = 1/2 NPT - 1/4 NPT (N/A for YT-3350)
Ingress Protection NEMA 4X, IP66
ATEX / IECEx / EAC Communications
Ex ia IIC T5/T6 Gb 0 = None
Ex ia IIIC T100°C/T85°C Db IP66 2 = HART protocol communication
3 = Profibus PA1
CCC 4 = Foundation Fieldbus1
Ex ia IIC T5/T6 Gb
Ex iaD 21 T1 00/T85 Output Options
0 = None
KCs 1 = 4 to 20 mA feedback
Ex ia IIC T6/T5 22 = Limit Switch - Mechanical Type
Ex ia IIIC T85°C/T100°C 33 = Limit Switch - Proximity Type
CSA 42 = 4 to 20 mA + Limit Switch - Mechanical Type
CSA certificate 53 = 4 to 20 mA + Limit Switch - Proximity Type
Explosion
Protection FM Operating Temp. (Non-explosionproof)4
Type Class I, Div 1, Groups A, B, C & D S = -30 to +85 °C (-22 to +185 °F) (N/A for EAC)
Class I, Zone 0 Aex ia IIC L = -40 to +85 °C (-40 to +185 °F)
Class II/III, Div 1, Groups E, F & G A = -55 to +85 °C (-67 to +185 °F) (EAC only)
Class I/II/III, Div 2, Groups A, B, C, D, E, F & G
NEMA Type 4X, IP66, IP54 Notes:
1. Only available to ATEX/IECEx and Output Option code 0. Potentiometer
Ambient temp: -40 to +60°C (T5) / -40 to +40°C feedback sensor is only applicable. Arctic temperature option is not available.
(T6)
2. Only S, L of Operating Temperature are available for 2, 4 of Output Options.
NEPSI This option is only available with potentiometer feedback sensor.
Ex ia IIC T5/T6 3. Only S of Operating Temperature is available for 3, 5 of Output Options. This
INMETRO option is only available with potentiometer feedback sensor.
Ex ia IIC T5/T6 Gb 4. This option is just the normal operating temperature of the product and is
Ex ia IIIC T100°C/T85°C Db not related to explosion protection temperature. See certificates for explosion
HART (ver.7) protection temperature.
Communication
Profibus PA1
(Option)
Foundation Fieldbus1
Mechanical
125 VAC, 3 A / 30 VDC, 2 A
L/S Type (Omron)
Rating Proximity
8.2 VDC, 8.2 mA
Type (P&F)
Weight 2 kg (4.4 lb) 5.1 kg (11.2 lb)
17